Whole-Body Computed Tomography Using Low-Dose Biphasic Injection Protocol With Adaptive Statistical Iterative Reconstruction V: Assessment of Dose Reduction and Image Quality in Trauma Patients

Whole-Body Computed Tomography Using Low-Dose Biphasic Injection Protocol With Adaptive... Aim This study aimed to evaluate potential dose savings on a revised protocol for whole-body computed tomography and image quality after implementing Adaptive Statistical Iterative Reconstruction V (ASiR-V) algorism for trauma patients and compare it with routine protocol. Materials and Methods One hundred trauma patients were classified into 2 groups using 2 different scanning protocols. Group A (n = 50; age, 32.48 ± 8.09 years) underwent routine 3-phase protocol. Group B (n = 50; age, 35.94 ± 13.57 years) underwent biphasic injection protocol including unenhanced scan for the brain and cervical spines, followed by a 1-step acquisition of the thorax, abdomen, and pelvis. The ASiR-V level was kept at 50% for all examinations, and then studies were reconstructed at 0% ASiR-V level. Radiation dose, total acquisition time, and image count were compared between groups (A and B). Two radiologists independently graded image quality and artifacts between both groups and 2 ASiR-V levels (0 and 50%). Results The mean (±SD) dose-length product value for postcontrast scans in group A was 1602.3 ± 271.8 mGy · cm and higher when compared with group B (P < 0.001), which was 951.1 ± 359.6 mGy · cm. Biphasic injection protocol gave a dose reduction of 40.4% and reduced the total acquisition time by 11.4% and image count by 37.6%. There was no statistically significant difference between the image quality scores for both groups; however, group A scored higher grades (4.62 ± 0.56 and 4.56 ± 0.67). Similarly, the image quality scores for both ASiR-V levels in both groups were not significantly different. Conclusions Biphasic computed tomography protocol reduced radiation dose with maintenance of diagnostic accuracy and image quality after implementing ASiR-V algorism. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Computer Assisted Tomography Wolters Kluwer Health

Whole-Body Computed Tomography Using Low-Dose Biphasic Injection Protocol With Adaptive Statistical Iterative Reconstruction V: Assessment of Dose Reduction and Image Quality in Trauma Patients

Loading next page...
 
/lp/wolters-kluwer-health/whole-body-computed-tomography-using-low-dose-biphasic-injection-0V0Czc3zfN

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
Wolters Kluwer Health
Copyright
Copyright © 2019 Wolters Kluwer Health, Inc. All rights reserved.
ISSN
0363-8715
eISSN
1532-3145
DOI
10.1097/RCT.0000000000000907
Publisher site
See Article on Publisher Site

Abstract

Aim This study aimed to evaluate potential dose savings on a revised protocol for whole-body computed tomography and image quality after implementing Adaptive Statistical Iterative Reconstruction V (ASiR-V) algorism for trauma patients and compare it with routine protocol. Materials and Methods One hundred trauma patients were classified into 2 groups using 2 different scanning protocols. Group A (n = 50; age, 32.48 ± 8.09 years) underwent routine 3-phase protocol. Group B (n = 50; age, 35.94 ± 13.57 years) underwent biphasic injection protocol including unenhanced scan for the brain and cervical spines, followed by a 1-step acquisition of the thorax, abdomen, and pelvis. The ASiR-V level was kept at 50% for all examinations, and then studies were reconstructed at 0% ASiR-V level. Radiation dose, total acquisition time, and image count were compared between groups (A and B). Two radiologists independently graded image quality and artifacts between both groups and 2 ASiR-V levels (0 and 50%). Results The mean (±SD) dose-length product value for postcontrast scans in group A was 1602.3 ± 271.8 mGy · cm and higher when compared with group B (P < 0.001), which was 951.1 ± 359.6 mGy · cm. Biphasic injection protocol gave a dose reduction of 40.4% and reduced the total acquisition time by 11.4% and image count by 37.6%. There was no statistically significant difference between the image quality scores for both groups; however, group A scored higher grades (4.62 ± 0.56 and 4.56 ± 0.67). Similarly, the image quality scores for both ASiR-V levels in both groups were not significantly different. Conclusions Biphasic computed tomography protocol reduced radiation dose with maintenance of diagnostic accuracy and image quality after implementing ASiR-V algorism.