Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

MIP Improves Detection of Brain Metastases

MIP Improves Detection of Brain Metastases Purpose This study aimed to compare the sensitivity for detection of brain metastases using postcontrast 3-dimensional, T1W-gradient echo sequence (3DT1W) and maximum intensity projections (MIPs) obtained from the same data set. Materials and Methods A prospective analysis of patients with known brain metastases was performed. We compared 1-mm postcontrast 3DT1W with 6-mm MIP reconstructions obtained from the same images (MIP-3DT1) in 95 patients using 1.5 (42 patients) and 3 T (53 patient). Two independent readers analyzed all studies and the examinations were presented in anonymized and random fashion for a total of 190 interpretations per observer. One reader had more than 20 years of experience and the second reader had 1 year of experience. Results The least experienced observer found 542 brain metastases on postcontrast non-MIP 3DT1W and 605 with the MIP-3DT1 technique. For this observer, use of MIP resulted in increased number of detected metastases in 36% of patients regardless of field strength. The more experienced observer found 589 brain metastases on non-MIP 3DT1W and 621 with the MIP-3DT1 technique and the use of the latter also resulted in increased detection of metastases in 33% of patients regardless of field strength. Conclusions In our study, we found that using MIP-3DT1 reconstructions of previously obtained postcontrast 3DT1W improved detection of brain metastases. This improvement was experienced by both the junior and experienced neuroradiologists and was also better at 3.0 T than at 1.5 T. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Computer Assisted Tomography Wolters Kluwer Health

Loading next page...
 
/lp/wolters-kluwer-health/mip-improves-detection-of-brain-metastases-uIbwl2IcsN

References (12)

Publisher
Wolters Kluwer Health
Copyright
Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved.
ISSN
0363-8715
eISSN
1532-3145
DOI
10.1097/RCT.0000000000000466
pmid
27529685
Publisher site
See Article on Publisher Site

Abstract

Purpose This study aimed to compare the sensitivity for detection of brain metastases using postcontrast 3-dimensional, T1W-gradient echo sequence (3DT1W) and maximum intensity projections (MIPs) obtained from the same data set. Materials and Methods A prospective analysis of patients with known brain metastases was performed. We compared 1-mm postcontrast 3DT1W with 6-mm MIP reconstructions obtained from the same images (MIP-3DT1) in 95 patients using 1.5 (42 patients) and 3 T (53 patient). Two independent readers analyzed all studies and the examinations were presented in anonymized and random fashion for a total of 190 interpretations per observer. One reader had more than 20 years of experience and the second reader had 1 year of experience. Results The least experienced observer found 542 brain metastases on postcontrast non-MIP 3DT1W and 605 with the MIP-3DT1 technique. For this observer, use of MIP resulted in increased number of detected metastases in 36% of patients regardless of field strength. The more experienced observer found 589 brain metastases on non-MIP 3DT1W and 621 with the MIP-3DT1 technique and the use of the latter also resulted in increased detection of metastases in 33% of patients regardless of field strength. Conclusions In our study, we found that using MIP-3DT1 reconstructions of previously obtained postcontrast 3DT1W improved detection of brain metastases. This improvement was experienced by both the junior and experienced neuroradiologists and was also better at 3.0 T than at 1.5 T.

Journal

Journal of Computer Assisted TomographyWolters Kluwer Health

Published: Apr 1, 2017

There are no references for this article.