Criteria for a suitable reference cuff for validation studies of blood pressure measuring devices in people with arm circumference between 43 and 50 cm

Criteria for a suitable reference cuff for validation studies of blood pressure measuring devices... Objective Recommendations about the dimensions of the reference cuff for device validations in people with arm size >42 cm are still unavailable. The aim of this study was to identify the criteria for an appropriate reference cuff for validation studies in people with upper arm circumference between 43 and 50 cm. Methods In 20 adults with upper arm circumference between 43 and 50 cm (X-large group), 34 subjects with arm circumference between 37 and 42 cm and 78 subjects with arm circumference <37 cm cylindrical and tronco-conical cuffs were compared. In all participants, the pressure transmitted to the arm under the two cuffs was measured using a paper-thin pressure sensor. Results In the X-large group, all participants had an arm slant angle <86.0°. In this group, the difference between the pressure detected on the arm surface with the sensor using the cylindrical versus the tronco-conical cuff (13.5 mmHg) was larger than in the group with an arm circumference of 37–to 42 cm and the group with a circumference <37 cm (3.7 and 0.6 mmHg, respectively, P < 0.001 versus both). In the whole sample, the between-cuff pressure difference was proportional to the conical shape of the arm (P < 0.001). Conclusions These data suggest that in people with arm size between 43 and 50 cm the reference cuff for validation studies should have a conical shape with an 84–85° slant angle. To comply with current guidelines, an 18.5 × 37.0 cm bladder should be used which would allow proper cuffing in the large majority of subjects. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Blood Pressure Monitoring Wolters Kluwer Health

Criteria for a suitable reference cuff for validation studies of blood pressure measuring devices in people with arm circumference between 43 and 50 cm

Loading next page...
 
/lp/wolters-kluwer-health/criteria-for-a-suitable-reference-cuff-for-validation-studies-of-blood-OqJn7znRGq

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
Wolters Kluwer Health
Copyright
Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.
ISSN
1359-5237
eISSN
1473-5725
DOI
10.1097/mbp.0000000000000630
Publisher site
See Article on Publisher Site

Abstract

Objective Recommendations about the dimensions of the reference cuff for device validations in people with arm size >42 cm are still unavailable. The aim of this study was to identify the criteria for an appropriate reference cuff for validation studies in people with upper arm circumference between 43 and 50 cm. Methods In 20 adults with upper arm circumference between 43 and 50 cm (X-large group), 34 subjects with arm circumference between 37 and 42 cm and 78 subjects with arm circumference <37 cm cylindrical and tronco-conical cuffs were compared. In all participants, the pressure transmitted to the arm under the two cuffs was measured using a paper-thin pressure sensor. Results In the X-large group, all participants had an arm slant angle <86.0°. In this group, the difference between the pressure detected on the arm surface with the sensor using the cylindrical versus the tronco-conical cuff (13.5 mmHg) was larger than in the group with an arm circumference of 37–to 42 cm and the group with a circumference <37 cm (3.7 and 0.6 mmHg, respectively, P < 0.001 versus both). In the whole sample, the between-cuff pressure difference was proportional to the conical shape of the arm (P < 0.001). Conclusions These data suggest that in people with arm size between 43 and 50 cm the reference cuff for validation studies should have a conical shape with an 84–85° slant angle. To comply with current guidelines, an 18.5 × 37.0 cm bladder should be used which would allow proper cuffing in the large majority of subjects.

Journal

Blood Pressure MonitoringWolters Kluwer Health

Published: Feb 13, 2023

References