Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Results of the ASTM field test of tristimulus weighting functions

Results of the ASTM field test of tristimulus weighting functions In 1993, the American Society for Testing and Materials carried out a field test of newly calculated tristimulus weighting factors. These weighting factors had been calculated by a method proposed by Venable. the test also included a method of correction for bandpass dependence put forth by Stearns. the purpose of the trial was to assess the possible reduction in bandpass dependence introduced by each of these sets of weights. A large number of sets of spectral data were gathered from the cooperators in the field test. Results of integration by the various sets of tristimulus weighting factors were calculated. A total of 15 120 color differences were calculated and statistics were derived to test the probable error resulting from each method of correction. Errors attributable to bandpass dependence were on the order of a few tenths to as much as one CIELAB unit when uncorrected weight sets were used. These errors could be reduced to a few hundreths of a CIELAB unit, and in some cases to a few thousandths of a unit, by employing one correcting strategy or the other. an overall mix of strategies was ultimately chosen to minimize the bandpass dependence over the entire range of weight sets. Utilizing this mixed strategy, the median error introduced into 10‐nm integration by bandpass dependence was only 0.004 CIELAB units. © 1995 John Wiley & Sons, Inc. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Color Research & Application Wiley

Results of the ASTM field test of tristimulus weighting functions

Color Research & Application , Volume 20 (1) – Feb 1, 1995

Loading next page...
 
/lp/wiley/results-of-the-astm-field-test-of-tristimulus-weighting-functions-3cvDHdLPtq

References (5)

Publisher
Wiley
Copyright
Copyright © 1995 Wiley Periodicals, Inc., A Wiley Company
ISSN
0361-2317
eISSN
1520-6378
DOI
10.1002/col.5080200108
Publisher site
See Article on Publisher Site

Abstract

In 1993, the American Society for Testing and Materials carried out a field test of newly calculated tristimulus weighting factors. These weighting factors had been calculated by a method proposed by Venable. the test also included a method of correction for bandpass dependence put forth by Stearns. the purpose of the trial was to assess the possible reduction in bandpass dependence introduced by each of these sets of weights. A large number of sets of spectral data were gathered from the cooperators in the field test. Results of integration by the various sets of tristimulus weighting factors were calculated. A total of 15 120 color differences were calculated and statistics were derived to test the probable error resulting from each method of correction. Errors attributable to bandpass dependence were on the order of a few tenths to as much as one CIELAB unit when uncorrected weight sets were used. These errors could be reduced to a few hundreths of a CIELAB unit, and in some cases to a few thousandths of a unit, by employing one correcting strategy or the other. an overall mix of strategies was ultimately chosen to minimize the bandpass dependence over the entire range of weight sets. Utilizing this mixed strategy, the median error introduced into 10‐nm integration by bandpass dependence was only 0.004 CIELAB units. © 1995 John Wiley & Sons, Inc.

Journal

Color Research & ApplicationWiley

Published: Feb 1, 1995

There are no references for this article.