Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Percutaneous Treatment for Mitral Regurgitation: The QuantumCor System

Percutaneous Treatment for Mitral Regurgitation: The QuantumCor System Aims: Percutaneous edge‐to‐edge techniques and annuloplasty have been used to treat mitral regurgitation (MR). However, neither intervention can be performed reliably a second time and, with annuloplasty, a foreign body is left behind. The mitral and tricuspid annuli are areas of dense collagen ( ); treatment with radiofrequency (RF) energy in sheep reduces their size, and can be repeated without affecting the coronary sinus. RF energy may also be used in leaflet procedures. Our aim was to improve mitral valve competence using techniques that can be incorporated into a minimally invasive approach. 1 This trichrome stain slide shows the amount of collagen present in the mitral annulus (in green). Methods: In open‐heart procedures in 16 healthy sheep (6 with naturally occurring MR), we used a malleable probe (QuantumCor, Inc., Lake Forest, CA) that conforms to the annular shape to deliver RF energy via a standard generator to replicate a surgical mitral annular ring. Four segments of the posterior mitral valve annulus were treated while on cardiopulmonary support via a left thoracotomy with access via the atrial appendage. Seven sheep were followed chronically. Results: All sheep underwent intracardiac echocardiography (ICE) or direct circumferential measurement of the mitral annulus before and after RF therapy. RF therapy was administered in less than 4 minutes in each case, and the mean anteroposterior (AP) annular distance was reduced by a mean of 5.75 ± 0.86 mm (23.8% reduction, P< 0.001). In the 6 sheep with nonischemic MR, regurgitation was eliminated. Acute histopathology (HP) demonstrated no damage to the leaflets, coronary sinuses, or coronary arteries. At 30 days, the AP distance continued to be reduced in the 7 surviving sheep (mean 5.0 ± .6 mm, 21.4% reduction, P< 0.001). Conclusions: In a sheep model, RF energy applied for less than 4 minutes per case at subablative temperatures in four quadrants of the posterior mitral valve annulus reduced the AP and circumferential annular distances significantly, and eliminated nonischemic MR. Results will need to be confirmed in follow‐up studies to determine safety and efficacy. RF energy administered as a novel, percutaneous method of mitral valve annuloplasty may have the potential to reduce morbidity and mortality associated with current surgical techniques. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Interventional Cardiology Wiley

Percutaneous Treatment for Mitral Regurgitation: The QuantumCor System

Loading next page...
 
/lp/wiley/percutaneous-treatment-for-mitral-regurgitation-the-quantumcor-system-uioE529CAs

References (27)

Publisher
Wiley
Copyright
2008, the Authors Journal compilation ©2008, Blackwell Publishing, Inc.
ISSN
0896-4327
eISSN
1540-8183
DOI
10.1111/j.1540-8183.2007.00333.x
pmid
18248359
Publisher site
See Article on Publisher Site

Abstract

Aims: Percutaneous edge‐to‐edge techniques and annuloplasty have been used to treat mitral regurgitation (MR). However, neither intervention can be performed reliably a second time and, with annuloplasty, a foreign body is left behind. The mitral and tricuspid annuli are areas of dense collagen ( ); treatment with radiofrequency (RF) energy in sheep reduces their size, and can be repeated without affecting the coronary sinus. RF energy may also be used in leaflet procedures. Our aim was to improve mitral valve competence using techniques that can be incorporated into a minimally invasive approach. 1 This trichrome stain slide shows the amount of collagen present in the mitral annulus (in green). Methods: In open‐heart procedures in 16 healthy sheep (6 with naturally occurring MR), we used a malleable probe (QuantumCor, Inc., Lake Forest, CA) that conforms to the annular shape to deliver RF energy via a standard generator to replicate a surgical mitral annular ring. Four segments of the posterior mitral valve annulus were treated while on cardiopulmonary support via a left thoracotomy with access via the atrial appendage. Seven sheep were followed chronically. Results: All sheep underwent intracardiac echocardiography (ICE) or direct circumferential measurement of the mitral annulus before and after RF therapy. RF therapy was administered in less than 4 minutes in each case, and the mean anteroposterior (AP) annular distance was reduced by a mean of 5.75 ± 0.86 mm (23.8% reduction, P< 0.001). In the 6 sheep with nonischemic MR, regurgitation was eliminated. Acute histopathology (HP) demonstrated no damage to the leaflets, coronary sinuses, or coronary arteries. At 30 days, the AP distance continued to be reduced in the 7 surviving sheep (mean 5.0 ± .6 mm, 21.4% reduction, P< 0.001). Conclusions: In a sheep model, RF energy applied for less than 4 minutes per case at subablative temperatures in four quadrants of the posterior mitral valve annulus reduced the AP and circumferential annular distances significantly, and eliminated nonischemic MR. Results will need to be confirmed in follow‐up studies to determine safety and efficacy. RF energy administered as a novel, percutaneous method of mitral valve annuloplasty may have the potential to reduce morbidity and mortality associated with current surgical techniques.

Journal

Journal of Interventional CardiologyWiley

Published: Apr 1, 2008

There are no references for this article.