Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Increased Apoptotic Cell Death in the Neointima after Stent‐Based Vascular Irradiation : Role of Radiation‐Induced Apoptosis for Restenosis Reduction

Increased Apoptotic Cell Death in the Neointima after Stent‐Based Vascular Irradiation : Role of... Background: Restenosis after stent implantation is a common problem faced today by interventional cardiologists. It is primarily caused by excessive neointimal growth. Early clinical studies showed substantial reductions of neointimal volumes within bodies of32P radioactive coronary stents. Radiotherapy induces programmed cell death (apoptosis) in tumors but there is still debate whether irradiation causes apoptosis in arteries. Methods: We compared the time course of neointimal apoptosis after implanting 7‐mm long 32P radioactive slotted tubular stents in rabbit iliac arteries. The stents were homogeneously ion‐implanted with 32P at activity levels of 0.5 and 6 μCi. These stents produce continuous beta‐particle emission at very low dose rates. Neointima formation was compared with nonradioactive stents by histomorphometry after 1, 4, and 12 weeks. Apoptosis was detected using the terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL) assay method and transmission electron microscopy. Results: At an early follow‐up of 1 week after stent implantation, no changes in neointimal apoptosis were found. The 32P stents at activities of 6 μCi, but not of 0.5 μCi, reduced neointimal crosssectional areas and cell numbers compared with control stents after 4 and 12 weeks. Apoptosis in the neointima increased after 4 weeks and was substantially elevated 12 weeks after implantation of 6 μCi 32P stents compared with 0.5 μCi and control stents (16% vs 6% and 3%, P < 0.01 for 6 vs 0.5 μCi and control stents, respectively). Conclusions: In this study, a dose dependent decrease in neointimal thickening and cell density within 32P beta‐particle emitting stents was associated with an increased frequency of apoptosis. This increase in apoptosis occurred late in the time course of vascular healing after the implantation of 32P beta‐particle emitting stents. Apoptosis seems to be involved in the mechanisms by which stent‐based vascular irradiation reduces neointimal hyperplasia. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Interventional Cardiology Wiley

Increased Apoptotic Cell Death in the Neointima after Stent‐Based Vascular Irradiation : Role of Radiation‐Induced Apoptosis for Restenosis Reduction

Loading next page...
 
/lp/wiley/increased-apoptotic-cell-death-in-the-neointima-after-stent-based-zvaF2s233V

References (19)

Publisher
Wiley
Copyright
Copyright © 1999 Wiley Subscription Services, Inc., A Wiley Company
ISSN
0896-4327
eISSN
1540-8183
DOI
10.1111/j.1540-8183.1999.tb00249.x
Publisher site
See Article on Publisher Site

Abstract

Background: Restenosis after stent implantation is a common problem faced today by interventional cardiologists. It is primarily caused by excessive neointimal growth. Early clinical studies showed substantial reductions of neointimal volumes within bodies of32P radioactive coronary stents. Radiotherapy induces programmed cell death (apoptosis) in tumors but there is still debate whether irradiation causes apoptosis in arteries. Methods: We compared the time course of neointimal apoptosis after implanting 7‐mm long 32P radioactive slotted tubular stents in rabbit iliac arteries. The stents were homogeneously ion‐implanted with 32P at activity levels of 0.5 and 6 μCi. These stents produce continuous beta‐particle emission at very low dose rates. Neointima formation was compared with nonradioactive stents by histomorphometry after 1, 4, and 12 weeks. Apoptosis was detected using the terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL) assay method and transmission electron microscopy. Results: At an early follow‐up of 1 week after stent implantation, no changes in neointimal apoptosis were found. The 32P stents at activities of 6 μCi, but not of 0.5 μCi, reduced neointimal crosssectional areas and cell numbers compared with control stents after 4 and 12 weeks. Apoptosis in the neointima increased after 4 weeks and was substantially elevated 12 weeks after implantation of 6 μCi 32P stents compared with 0.5 μCi and control stents (16% vs 6% and 3%, P < 0.01 for 6 vs 0.5 μCi and control stents, respectively). Conclusions: In this study, a dose dependent decrease in neointimal thickening and cell density within 32P beta‐particle emitting stents was associated with an increased frequency of apoptosis. This increase in apoptosis occurred late in the time course of vascular healing after the implantation of 32P beta‐particle emitting stents. Apoptosis seems to be involved in the mechanisms by which stent‐based vascular irradiation reduces neointimal hyperplasia.

Journal

Journal of Interventional CardiologyWiley

Published: Aug 1, 1999

There are no references for this article.