Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Fire resistance of hot‐dip galvanized steel structures

Fire resistance of hot‐dip galvanized steel structures EDITOR‘S RECOMMENDATIONS This paper discusses the effects of hot dip also offers calculation methods to verify for an R30 requirement through hot dip galvanizing on the fire resistance of struc - the fire resistance. Here it is necessary to galvanized steel members. tural steel members. It has been publis- determine the temperature of the steel hed in German in Stahlbau 1/2019. section according to DIN EN 1993-1-2 Mensinger, M. and Gaigl, C.: Feuerwider- and to fulfil the ultimate limit state de- stand verzinkter Stahlkonstruktionen, Abstract: Once a fire resistance rating of sign, with respect to the reduction of the Stahlbau 88 (2019), Heft 1. at least 30 min is necessary, it must be material characteristics. For this purpose, proofed that the load-bearing behaviour positive effects of hot dip galvanization www.ernst-und-sohn.de/en/stahlbau still fulfils the static demands. To protect on the temperature development of steel steel constructions from too high tempe- members under fire exposure are investi- https://onlinelibrary.wiley.com/ ratures in the accidental design situation gated in a research project of the Techni- doi/10.1002/stab.201800034 of a fire, the state of the art is a passive cal University of Munich. The aim is thus fire protection. However, the Eurocode to avoid additional passive fire protection 134 Steel Construction 12 (2019), No. 2 http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Steel Construction: Design and Research Wiley

Fire resistance of hot‐dip galvanized steel structures

Steel Construction: Design and Research , Volume 12 (2) – May 1, 2019

Loading next page...
 
/lp/wiley/fire-resistance-of-hot-dip-galvanized-steel-structures-oiOmGmWWox

References (0)

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
Wiley
Copyright
"© 2019 Ernst & Sohn Verlag für Architektur und technische Wissenschaften GmbH & Co. KG, Berlin"
ISSN
1867-0520
eISSN
1867-0539
DOI
10.1002/stco.201970210
Publisher site
See Article on Publisher Site

Abstract

EDITOR‘S RECOMMENDATIONS This paper discusses the effects of hot dip also offers calculation methods to verify for an R30 requirement through hot dip galvanizing on the fire resistance of struc - the fire resistance. Here it is necessary to galvanized steel members. tural steel members. It has been publis- determine the temperature of the steel hed in German in Stahlbau 1/2019. section according to DIN EN 1993-1-2 Mensinger, M. and Gaigl, C.: Feuerwider- and to fulfil the ultimate limit state de- stand verzinkter Stahlkonstruktionen, Abstract: Once a fire resistance rating of sign, with respect to the reduction of the Stahlbau 88 (2019), Heft 1. at least 30 min is necessary, it must be material characteristics. For this purpose, proofed that the load-bearing behaviour positive effects of hot dip galvanization www.ernst-und-sohn.de/en/stahlbau still fulfils the static demands. To protect on the temperature development of steel steel constructions from too high tempe- members under fire exposure are investi- https://onlinelibrary.wiley.com/ ratures in the accidental design situation gated in a research project of the Techni- doi/10.1002/stab.201800034 of a fire, the state of the art is a passive cal University of Munich. The aim is thus fire protection. However, the Eurocode to avoid additional passive fire protection 134 Steel Construction 12 (2019), No. 2

Journal

Steel Construction: Design and ResearchWiley

Published: May 1, 2019

There are no references for this article.