Considerations on the calibration of color displays assuming constant channel chromaticity

Considerations on the calibration of color displays assuming constant channel chromaticity To calibrate a CRT color monitor, several assumptions are often made about its performance, one of the most accepted being constanel channel chromaticity. However, when the measurements are taken in a extended field of CRT screen, where it is assumed that only one primary phosphor is excited, the relative spectral radiance of the other primary phosphors that are contained in that field also contributes, if the background luminance is not zero. This contribution is greater at low levels of RGB channel stimulation and would invalidate the results obtained with calibration methods based on the hypothesis of constancy of chromaticity coordinates of RGB channels. We have studied this effect on the calibration of the CRT color monitor and, as a result, we propose a calibration that takes this effect into account. to evaluate the accuracy of the method, we have calculated color differences between the chromaticity that we wanted to reproduce and the one displayed with the CIELUV color‐difference formula, and the color tolerances with the line element of MacAdam ellipses. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Color Research & Application Wiley

Considerations on the calibration of color displays assuming constant channel chromaticity

Loading next page...
 
/lp/wiley/considerations-on-the-calibration-of-color-displays-assuming-constant-vlpYe3V2dk

References (13)

Publisher
Wiley
Copyright
Copyright © 1995 Wiley Periodicals, Inc., A Wiley Company
ISSN
0361-2317
eISSN
1520-6378
DOI
10.1002/col.5080200606
Publisher site
See Article on Publisher Site

Abstract

To calibrate a CRT color monitor, several assumptions are often made about its performance, one of the most accepted being constanel channel chromaticity. However, when the measurements are taken in a extended field of CRT screen, where it is assumed that only one primary phosphor is excited, the relative spectral radiance of the other primary phosphors that are contained in that field also contributes, if the background luminance is not zero. This contribution is greater at low levels of RGB channel stimulation and would invalidate the results obtained with calibration methods based on the hypothesis of constancy of chromaticity coordinates of RGB channels. We have studied this effect on the calibration of the CRT color monitor and, as a result, we propose a calibration that takes this effect into account. to evaluate the accuracy of the method, we have calculated color differences between the chromaticity that we wanted to reproduce and the one displayed with the CIELUV color‐difference formula, and the color tolerances with the line element of MacAdam ellipses.

Journal

Color Research & ApplicationWiley

Published: Dec 1, 1995

There are no references for this article.