Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Anwendung einer Ammoniak‐gassensitiven Elektrode zur Ammonium‐Stickstoffbestimmung in organischen Düngern

Anwendung einer Ammoniak‐gassensitiven Elektrode zur Ammonium‐Stickstoffbestimmung in organischen... A gas‐sensitive electrode for the determination of ammonia was tested on the basis of potentiometry by means of parts of measuring devices from the CMEA region. Samples of water, cattle slurry, pig slurry and silo seepage water in the range of concentrations of 10−5 … 10−1 mol/1 NH4‐N can be measured. Before measurement the samples have to get pH 11 and have to be diluted, if necessary. A maximum period of time of about eight minutes is required for attaining the potential constancy. The relative standard deviation varies between 0.1 and 4.79%; the rate of retrieval was 99.1% on an average. The results of the potentiometric measurements were equivalent to those of the acidimetric measuring method. The practical advantages consist in a low expenditure of material, energy and time. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Acta hydrochimica et hydrobiologica Wiley

Anwendung einer Ammoniak‐gassensitiven Elektrode zur Ammonium‐Stickstoffbestimmung in organischen Düngern

Loading next page...
 
/lp/wiley/anwendung-einer-ammoniak-gassensitiven-elektrode-zur-ammonium-Ox46n3oNu0

References (11)

Publisher
Wiley
Copyright
Copyright © 1989 Wiley Subscription Services, Inc., A Wiley Company
ISSN
0323-4320
eISSN
1521-401X
DOI
10.1002/aheh.19890170304
Publisher site
See Article on Publisher Site

Abstract

A gas‐sensitive electrode for the determination of ammonia was tested on the basis of potentiometry by means of parts of measuring devices from the CMEA region. Samples of water, cattle slurry, pig slurry and silo seepage water in the range of concentrations of 10−5 … 10−1 mol/1 NH4‐N can be measured. Before measurement the samples have to get pH 11 and have to be diluted, if necessary. A maximum period of time of about eight minutes is required for attaining the potential constancy. The relative standard deviation varies between 0.1 and 4.79%; the rate of retrieval was 99.1% on an average. The results of the potentiometric measurements were equivalent to those of the acidimetric measuring method. The practical advantages consist in a low expenditure of material, energy and time.

Journal

Acta hydrochimica et hydrobiologicaWiley

Published: Jan 1, 1989

There are no references for this article.