Absolute reflectance factor calibration for goniospectrophotometry

Absolute reflectance factor calibration for goniospectrophotometry Currently, spectrophotometric standard reference materials are calibrated only using the CIE recommended illumination and viewing geometries. A need exists for standards that have been calibrated at many other combinations of illumination and viewing angles. The common practice has been to assume that a primary transfer standard such as BaSO4 is Lambertian even though its non‐Lambertian behavior is well documented. This study was undertaken to develop a practical standard for this type of metrology. Two diffuse materials, BaSO4 and PTFE, were characterized goniospectrophotometrically. Bidirectional absolute spectral reflectance factors were determined for 60 combinations of illumination and view angles in a single plane. Neither material was found to be Lambertian and both failed to completely depolarize reflected radiation. The results were modeled using principal components analysis. The resulting model allows the determination of bidirectional spectral reflectances factors with a minimum effort. PTFE powder can be prepared repeatably with no significant effect on the measured reflectance properties, thus indicating that it would be a suitable primary transfer standard for goniospectrophotometry. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Color Research & Application Wiley

Absolute reflectance factor calibration for goniospectrophotometry

Loading next page...
 
/lp/wiley/absolute-reflectance-factor-calibration-for-goniospectrophotometry-Q4sR0GYOfn

References (17)

Publisher
Wiley
Copyright
Copyright © 1990 Wiley Periodicals, Inc., A Wiley Company
ISSN
0361-2317
eISSN
1520-6378
DOI
10.1002/col.5080150605
Publisher site
See Article on Publisher Site

Abstract

Currently, spectrophotometric standard reference materials are calibrated only using the CIE recommended illumination and viewing geometries. A need exists for standards that have been calibrated at many other combinations of illumination and viewing angles. The common practice has been to assume that a primary transfer standard such as BaSO4 is Lambertian even though its non‐Lambertian behavior is well documented. This study was undertaken to develop a practical standard for this type of metrology. Two diffuse materials, BaSO4 and PTFE, were characterized goniospectrophotometrically. Bidirectional absolute spectral reflectance factors were determined for 60 combinations of illumination and view angles in a single plane. Neither material was found to be Lambertian and both failed to completely depolarize reflected radiation. The results were modeled using principal components analysis. The resulting model allows the determination of bidirectional spectral reflectances factors with a minimum effort. PTFE powder can be prepared repeatably with no significant effect on the measured reflectance properties, thus indicating that it would be a suitable primary transfer standard for goniospectrophotometry.

Journal

Color Research & ApplicationWiley

Published: Dec 1, 1990

There are no references for this article.