Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

A Prospective Randomized Trial of Novoste Right Versus Judkins Catheters for Engagement of the Right Coronary Artery During Diagnostic Catheterization

A Prospective Randomized Trial of Novoste Right Versus Judkins Catheters for Engagement of the... There has been little technical advancement in catheter shape for diagnostic cardiac catheterization since the early reports of Sones and colleagues during the development of the procedure. In order to determine the utility of a new catheter that directly, without torque or rotation, engages the right coronary artery (RCA), one hundred patients were randomized between 6Fr standard RCA Judkins (6Fr R4) (Cordis Corporation, Miami, FL, USA) or 6Fr Novoste RCA catheters (Novoste Corporation, Aguadilla, Puerto Rico). Endpoints included the duration of the various aspects of the procedure and a qualitative and quantitative assessment of angiographic quality. The Novoste RCA catheters were associated with statistically decreased times of catheter insertion (42 ± 37 vs 90 ± 119 secs), and engagement (31 ± 35 vs 77 ± 117 secs), of the right coronary artery as compared to Judkins catheters. Judkins RCA catheters had a significantly higher primary success rate (96%) than the Novoste group (84%, P = 0.045). There was no difference in angiographic quality in either group and no complications occurred during the study. While taller patients (mean 68 in) had increased success with the Novoste catheter, no other clinical, demographic, or anatomical characteristics of the RCA orifice predicted successful engagement and angiography. The direct engagement Novoste RCA catheter is associated with a more expeditious procedure than Judkins catheters when they can engage the RCA orifice. However, Novoste catheters were less successful and required more frequent exchanges to complete the procedure. (J Interven Cardiol 1993; 6:213–218) http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Interventional Cardiology Wiley

A Prospective Randomized Trial of Novoste Right Versus Judkins Catheters for Engagement of the Right Coronary Artery During Diagnostic Catheterization

Loading next page...
 
/lp/wiley/a-prospective-randomized-trial-of-novoste-right-versus-judkins-4KGtG58dpL

References (14)

Publisher
Wiley
Copyright
Copyright © 1993 Wiley Subscription Services, Inc., A Wiley Company
ISSN
0896-4327
eISSN
1540-8183
DOI
10.1111/j.1540-8183.1993.tb00858.x
Publisher site
See Article on Publisher Site

Abstract

There has been little technical advancement in catheter shape for diagnostic cardiac catheterization since the early reports of Sones and colleagues during the development of the procedure. In order to determine the utility of a new catheter that directly, without torque or rotation, engages the right coronary artery (RCA), one hundred patients were randomized between 6Fr standard RCA Judkins (6Fr R4) (Cordis Corporation, Miami, FL, USA) or 6Fr Novoste RCA catheters (Novoste Corporation, Aguadilla, Puerto Rico). Endpoints included the duration of the various aspects of the procedure and a qualitative and quantitative assessment of angiographic quality. The Novoste RCA catheters were associated with statistically decreased times of catheter insertion (42 ± 37 vs 90 ± 119 secs), and engagement (31 ± 35 vs 77 ± 117 secs), of the right coronary artery as compared to Judkins catheters. Judkins RCA catheters had a significantly higher primary success rate (96%) than the Novoste group (84%, P = 0.045). There was no difference in angiographic quality in either group and no complications occurred during the study. While taller patients (mean 68 in) had increased success with the Novoste catheter, no other clinical, demographic, or anatomical characteristics of the RCA orifice predicted successful engagement and angiography. The direct engagement Novoste RCA catheter is associated with a more expeditious procedure than Judkins catheters when they can engage the RCA orifice. However, Novoste catheters were less successful and required more frequent exchanges to complete the procedure. (J Interven Cardiol 1993; 6:213–218)

Journal

Journal of Interventional CardiologyWiley

Published: Sep 1, 1993

There are no references for this article.