Access the full text.
Sign up today, get DeepDyve free for 14 days.
Hakyung Cho, Joohyeong Lee (2015)
A Study on the Optimal Positions of ECG Electrodes in a Garment for the Design of ECG-Monitoring Clothing for MaleJournal of Medical Systems, 39
A. Infantosi, D. Melges, C. Tierra-Criollo (2006)
Use of magnitude-squared coherence to identify the maximum driving response band of the somatosensory evoked potential.Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas, 39 12
Rama Rajanna, N. Sriraam, P. Vittal, Uma Arun (2020)
Performance Evaluation of Woven Conductive Dry Textile Electrodes for Continuous ECG Signals AcquisitionIEEE Sensors Journal, 20
A. Abbott (2005)
Diagnostic approach to palpitations.American family physician, 71 4
Dhruv Seshadri, Ryan Li, J. Voos, J. Rowbottom, Celeste Alfes, C. Zorman, Colin Drummond (2019)
Wearable sensors for monitoring the physiological and biochemical profile of the athleteNPJ Digital Medicine, 2
M. Baig, Shereen Afifi, H. Gholamhosseini, Farhaan Mirza (2019)
A Systematic Review of Wearable Sensors and IoT-Based Monitoring Applications for Older Adults – a Focus on Ageing Population and Independent LivingJournal of Medical Systems, 43
D. Nanchen (2018)
Resting heart rate: what is normal?Heart, 104
P. Xu, H. Zhang, Xi Tao (2008)
Textile-structured electrodes for electrocardiogramTextile Progress, 40
G. Clifford, F. Azuaje, P. McSharry (2006)
Advanced Methods And Tools for ECG Data Analysis
J. Lekieffre (1980)
[Sinoatrial node].Acta cardiologica, 35 1
M. Adam, M. Imboden, Emmanuel Schaffner, Eva Boes, F. Kronenberg, M. Pons, R. Bettschart, J. Barthélémy, C. Schindler, N. Probst-Hensch (2017)
The adverse impact of obesity on heart rate variability is modified by a NFE2L2 gene variant: The SAPALDIA cohort.International journal of cardiology, 228
A. Majumder, Yosuf ElSaadany, R. Young, D. Ucci (2019)
An Energy Efficient Wearable Smart IoT System to Predict Cardiac ArrestAdv. Hum. Comput. Interact., 2019
D. Nunan, G. Sandercock, D. Brodie (2010)
A Quantitative Systematic Review of Normal Values for Short‐Term Heart Rate Variability in Healthy AdultsPacing and Clinical Electrophysiology, 33
S. Yao, Yong Zhu (2016)
Nanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A ReviewJOM, 68
A. Soroudi, M. Skrifvars, V. Nierstrasz (2019)
Novel Skin-Electrode Conductive Adhesives to Improve the Quality of Recorded Body Signals in Smart Medical Garments, 32
Christina Orphanidou (2018)
Signal Quality Assessment in Physiological Monitoring
M. Vallejo, M. Márquez, V. Borja-Aburto, M. Cárdenas, A. Hermosillo (2005)
Age, body mass index, and menstrual cycle influence young women’s heart rate variabilityClinical Autonomic Research, 15
Narasimha N, Amit Kumar, Sudhir K (2015)
ASSOCIATION BETWEEN ECG VARIABLES AND BODY MASS INDEX: A CROSS – SECTIONAL STUDYJournal of Evolution of medical and Dental Sciences, 4
Tiina Föhr, J. Pietilä, E. Helander, T. Myllymäki, H. Lindholm, H. Rusko, U. Kujala (2016)
Physical activity, body mass index and heart rate variability-based stress and recovery in 16 275 Finnish employees: a cross-sectional studyBMC Public Health, 16
Masahiro Okada, M. Kakehashi (2014)
The influence of body mass index and outdoor temperature on the autonomic response to eating in healthy young Japanese womenSpringerPlus, 3
F. Romero, Encarnación Castillo, A. Rivadeneyra, A. Toral-Lopez, M. Becherer, F. Ruiz, N. Rodríguez, D. Morales (2019)
Inexpensive and flexible nanographene-based electrodes for ubiquitous electrocardiogram monitoringnpj Flexible Electronics, 3
Regina Xavier, Vitor Azevedo, P. Godoy, Arn Migowski, Antonio Ribeiro, R. Chaves, M. Correia, Carolina Xavier, Lucas Hashimoto, C. Weksler, N. Silva (2017)
Medium-term outcomes of 78,808 patients after heart valve surgery in a middle-income country: a nationwide population-based studyBMC Cardiovascular Disorders, 17
Fergal Connolly, D. Byrne, S. Lydon, C. Walsh, P. O’Connor (2017)
Barriers and facilitators related to the implementation of a physiological track and trigger system: A systematic review of the qualitative evidenceInternational Journal for Quality in Health Care, 29
M. Manikandan, D. kumar (2015)
PROGNOSTIC SIGNIFICANCE OF HRV FOR DIFFERENT AGE GROUPS
Marina Corrales, B. Torres, A. Esquivel, Marco Salazar, J. Orellana (2012)
Normal values of heart rate variability at rest in a young, healthy and active Mexican populationHealth, 4
Saeid Yazdanirad, H. Dehghan, Yaser Rahimi, M. Zeinodini, Mahnaz Shakeriyan (2015)
The Relationship Between Overweight and Heart Rate in Hot and Very Hot Weather Under Controlled ConditionsHealth Scope, 4
Raad Shebib, J. Bailey, P. Smittenaar, Daniel Perez, G. Mecklenburg, S. Hunter (2019)
Randomized controlled trial of a 12-week digital care program in improving low back painNPJ Digital Medicine, 2
H. Koo, Young-Jae Lee, Sunok Gi, Seonah Khang, Joohyeong Lee, Jae-Ho Lee, Min-Gyu Lim, Hee-Jung Park, J. Lee (2014)
The Effect of Textile-Based Inductive Coil Sensor Positions for Heart Rate MonitoringJournal of Medical Systems, 38
N. Hamza, L. Khriji, R. Tourki (2013)
Interference reduction in ECG signal acquisition: Ground electrode removal (case study)2013 International Conference on Computer Medical Applications (ICCMA)
Mayur M.Sevak, Tanmay D.Pawar (2019)
Wearable ECG Recorder with MATLABInternational Journal of Engineering and Advanced Technology
A. Bianchi, M. Méndez, S. Cerutti (2010)
Processing of Signals Recorded Through Smart Devices: Sleep-Quality AssessmentIEEE Transactions on Information Technology in Biomedicine, 14
Reinel Castrillón, Jairo Pérez, H. Andrade-Caicedo (2018)
Electrical performance of PEDOT:PSS-based textile electrodes for wearable ECG monitoring: a comparative studyBioMedical Engineering OnLine, 17
N. Sriraam, A. Srinivasulu, V. Prakash, Sarthak Sahoo (2019)
A Smart Textile Electrode Belt for ECG Recordings - A Pilot Study with Indian Population2019 2nd International Conference on Signal Processing and Communication (ICSPC)
N. Gokarneshan, P. Gopalakrishnan, B. Jeyanthi (2012)
Influence of Nanofinishes on the Antimicrobial Properties of FabricsNanomaterials, 2012
O. Postolache, P. Girão, E. Pinheiro, G. Postolache (2010)
Unobtrusive and Non-invasive Sensing Solutions for On-Line Physiological Parameters Monitoring
R. Havmøller, J. Carlson, F. Holmqvist, A. Herreros, C. Meurling, B. Olsson, P. Platonov (2007)
Age-related changes in P wave morphology in healthy subjectsBMC Cardiovascular Disorders, 7
Treasure Island (FL): StatPearls Publishing
C. Núñez, Libu Manjakkal, R. Dahiya (2019)
Energy autonomous electronic skinnpj Flexible Electronics, 3
C. Nishida (2004)
Appropriate body-mass index for Asian populations and its implications for policy and intervention strategiesThe Lancet, 363
M. Baig, H. Gholamhosseini, Aasia Moqeem, Farhaan Mirza, M. Lindén (2017)
A Systematic Review of Wearable Patient Monitoring Systems – Current Challenges and Opportunities for Clinical AdoptionJournal of Medical Systems, 41
Jiapu Pan, W. Tompkins (1985)
A Real-Time QRS Detection AlgorithmIEEE Transactions on Biomedical Engineering, BME-32
Hyun-Seung Cho, Su-Min Koo, Joohyeong Lee, Hakyung Cho, Da-Hye Kang, Ha-Young Song, J. Lee, Kang-Hwi Lee, Young-Jae Lee (2011)
Heart Monitoring Garments Using Textile Electrodes for Healthcare ApplicationsJournal of Medical Systems, 35
V. Marozas, A. Petrėnas, S. Daukantas, A. Lukoševičius (2011)
A comparison of conductive textile-based and silver/silver chloride gel electrodes in exercise electrocardiogram recordings.Journal of electrocardiology, 44 2
H. Dispirito, J. Mitchell, Peter Vardakas, S. Amir (2013)
Optimizing Novel ECG Electrodes
G. Clifford (2006)
ECG Statistics , Noise , Artifacts , and Missing Data
László Hejjel, I. Gal (2001)
Heart rate variability analysis.Acta physiologica Hungarica, 88 3-4
J. Struijk, C. Graff, Jørgen Kanters, J. Xue, A. Jensen, S. Schmidt (2014)
Coherence as a measure of noise in the ECGComputing in Cardiology 2014
S. Steltenkamp, K. Becher, T. Doerge, R. Ruff, K. Hoffmann (2009)
Electrode structures for acquisition and neural stimulation controlling the cardiovascular system2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
P. Gaur, R. Chhaparwal (2018)
Influence of low BMI on resting heart rate in different phases of menstrual cycle
G. Hassing, H. Wall, G. Westen, M. Kemme, A. Adiyaman, A. Elvan, J. Burggraaf, P. Gal (2019)
Body mass index related electrocardiographic findings in healthy young individuals with a normal body mass indexNetherlands Heart Journal, 27
Zhe Yang, Qihao Zhou, L. Lei, K. Zheng, W. Xiang (2016)
An IoT-cloud Based Wearable ECG Monitoring System for Smart HealthcareJournal of Medical Systems, 40
L. Tereshchenko, Jonathan Waks, M. Kabir, Elyar Ghafoori, A. Shvilkin, M. Josephson (2015)
Analysis of speed, curvature, planarity and frequency characteristics of heart vector movement to evaluate the electrophysiological substrate associated with ventricular tachycardiaComputers in biology and medicine, 65
Theingi Win, B. Venkatesh, G. Volpe, N. Mewton, P. Rizzi, Ravi Sharma, D. Strauss, J. Lima, L. Tereshchenko (2015)
Associations of electrocardiographic P-wave characteristics with left atrial function, and diffuse left ventricular fibrosis defined by cardiac magnetic resonance: The PRIMERI Study.Heart rhythm, 12 1
B. Farah, W. Prado, T. Tenório, R. Ritti-Dias (2013)
Heart rate variability and its relationship with central and general obesity in obese normotensive adolescentsEinstein, 11
C. Sia, M. Dalakoti, B. Tan, E. Lee, Xiayan Shen, Kangjie Wang, Joshua Lee, S. Arulanandam, W. Chow, T. Yeo, K. Yeo, T. Chua, R. Tan, C. Lam, D. Chong (2019)
A Population‐wide study of electrocardiographic (ECG) norms and the effect of demographic and anthropometric factors on selected ECG characteristics in young, Southeast Asian males—results from the Singapore Armed Forces ECG (SAFE) studyAnnals of Noninvasive Electrocardiology, 24
L. Beckmann, C. Neuhaus, G. Medrano, N. Jungbecker, M. Walter, T. Gries, S. Leonhardt (2010)
Characterization of textile electrodes and conductors using standardized measurement setupsPhysiological Measurement, 31
G. Berntson, J. Cacioppo, K. Quigley (1993)
Respiratory sinus arrhythmia: autonomic origins, physiological mechanisms, and psychophysiological implications.Psychophysiology, 30 2
T. Garcia, Neil Holtz (2013)
12-Lead ECG: The Art of Interpretation
Shwu-Eng Webb, Fred Kuchler (1913)
A ComparisonTexas Medical Journal, 29
X. Tao (2014)
Handbook of Smart TextilesHandbook of Smart Textiles
M. Poddar, Vinod Kumar, Yash Sharma (2015)
Heart rate variability: Analysis and classification of healthy subjects for different age groups2015 2nd International Conference on Computing for Sustainable Global Development (INDIACom)
T. Kannaian, R. Neelaveni, G. Thilagavathi (2013)
Design and development of embroidered textile electrodes for continuous measurement of electrocardiogram signalsJournal of Industrial Textiles, 42
Steffi Colyer, Polly McGuigan (2018)
Textile Electrodes Embedded in Clothing: A Practical Alternative to Traditional Surface Electromyography when Assessing Muscle Excitation during Functional Movements.Journal of sports science & medicine, 17 1
Dhruv Seshadri, Ryan Li, J. Voos, J. Rowbottom, Celeste Alfes, C. Zorman, Colin Drummond (2019)
Wearable sensors for monitoring the internal and external workload of the athleteNPJ Digital Medicine, 2
Improving Aluminum, Can Coatings, Jianyu Liang, Amy Zeng (2016)
WORCESTER POLYTECHNIC INSTITUTE MAJOR QUALIFYING PROJECT
M. Rienzo, F. Rizzo, G. Parati, M. Ferratini, G. Brambilla, P. Castiglioni (2005)
A textile-based wearable system for vital sign monitoring: applicability in cardiac patientsComputers in Cardiology, 2005
D. Palhares, M. Marcolino, T. Santos, J. Silva, P. Gomes, L. Ribeiro, P. Macfarlane, A. Ribeiro (2017)
Normal limits of the electrocardiogram derived from a large database of Brazilian primary care patientsBMC Cardiovascular Disorders, 17
R. Rossi, L. Vanderlei, Ana Gonçalves, F. Vanderlei, A. Bernardo, K. Yamada, Natália Silva, L. Abreu (2015)
Impact of obesity on autonomic modulation, heart rate and blood pressure in obese young peopleAutonomic Neuroscience, 193
(2018)
eBook ISBN: 978–3-319- 68415-4
Angel Villegas, D. McEneaney, O. Escalona (2019)
Arm-ECG Wireless Sensor System for Wearable Long-Term Surveillance of Heart ArrhythmiasElectronics
L. Vojtech, R. Bortel, M. Neruda, Milos Kozak (2013)
Wearable Textile Electrodes for ECG MeasurementAdvances in Electrical and Electronic Engineering, 11
Yong Kim, Honggang Wang (2014)
Textile-Based Body Sensor Networks and Biomedical Computing for Healthcare Applications
B. Lin, A. Wong, K. Tseng (2016)
Community-Based ECG Monitoring System for Patients with Cardiovascular DiseasesJournal of Medical Systems, 40
G. Valenza, E. Scilingo (2017)
Exploiting Physiological Sensors and Biosignal Processing to Enhance Monitoring Care in Mental Health
N. N. (1993)
12 Lead ECG InterpretationDimensions of Critical Care Nursing
M. Rienzo, V. Racca, F. Rizzo, B. Bordoni, G. Parati, P. Castiglioni, P. Meriggi, M. Ferratini (2013)
Evaluation of a textile-based wearable system for the electrocardiogram monitoring in cardiac patients.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 15 4
F. Shaffer, J. Ginsberg (2017)
An Overview of Heart Rate Variability Metrics and NormsFrontiers in Public Health, 5
K. Umetani, D. Singer, R. McCraty, M. Atkinson (1998)
Twenty-four hour time domain heart rate variability and heart rate: relations to age and gender over nine decades.Journal of the American College of Cardiology, 31 3
J. Bailey, A. Berson, A. Garson, L. Horan, P. Macfarlane, D. Mortara, C. Zywietz (1990)
Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology,Circulation, 81 2
R. Kleiger, R. Kleiger, R. Kleiger, J. Miller, J. Miller, J. Miller, J. Bigger, J. Bigger, J. Bigger, A. Moss, A. Moss, A. Moss (1987)
Decreased heart rate variability and its association with increased mortality after acute myocardial infarction.The American journal of cardiology, 59 4
J. Fatisson, Victor Oswald, F. Lalonde (2016)
Influence diagram of physiological and environmental factors affecting heart rate variability: an extended literature overviewHeart International, 11
Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations
Richard Gordan, J. Gwathmey, Lai-Hua Xie (2015)
Autonomic and endocrine control of cardiovascular function.World journal of cardiology, 7 4
PurposeThe diagnosis of unexplained syncope and sustained palpitations remains a challenging task for cardiology community. Continuous monitoring of cardiac activity is essential to know the pumping pattern of the heart for patients with mild and severe symptoms. Although attempts have been made towards developing wearable monitoring system, the demand for new system is still open due to affordability and accessibility to resource constrained settings.MethodThis research work proposes a wearable smart jacket with a single lead (Ag-NyW) textile sensor for continuous monitoring of electrocardiogram (ECG) signals. The wearable lead-I textile electrodes are evaluated in terms of visual inspection by the clinician, skin-electrode contact impedance characteristics; fidelity measures such as crest factor, signal band to noise band ratio, mean magnitude squared coherence; and ECG interval characteristics. Experimental study was carried with 212 healthy volunteers after due ethical clearance (age group 18–45 years), and RR variability and heart rate variability were assessed for different age groups and BMI levels. ResultsThe study revealed that the proposed textile electrodes are comparable to disposable (conventional Ag/AgCl gel) electrodes in terms of fidelity measures, skin-contact impedance, and ECG interval measures. The HRV for different age groups and BMI levels were found to be within the limits as reported in the literature.ConclusionFrom the current pilot study with Indian population, this cost-effective wearable ECG monitoring system will be helpful for long-term monitoring in resource constrained settings.
Research on Biomedical Engineering – Springer Journals
Published: Apr 26, 2021
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.