Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Utility of Follow-Up Echocardiograms in Uncomplicated PDA Device Closures Performed After Infancy

Utility of Follow-Up Echocardiograms in Uncomplicated PDA Device Closures Performed After Infancy IntroductionGuidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure after infancy.MethodsChart review was performed on patients who had a PDA closure ≥ 1 year of age between 1/1/2002 and 6/1/2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE ≥ 6 months after procedure, had a residual PDA or velocity > 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE ≥ 6 months after device placement. Time points included the initial TTE after the procedure, first TTE ≥ 6 months after procedure, and the most recent TTE.ResultsA total of 189 patients met the study criteria. The median age and weight at initial procedure were 2.7 (1.0–64.7) years and 12.5 (3.4–69.2) kg. Most recent TTE was performed 2.0 (0.4–17.0) years after PDA closure. There were no significant differences in fractional shortening (36.4 ± 5.0% vs. 36.9 ± 5.6%) or LPA velocity (1.1 ± 0.4 m/s vs. 1.1 ± 0.4 m/s) from initial to most recent TTE, respectively. Left ventricular internal diastolic diameter Z-score significantly decreased (1.4 ± 1.8 vs. − 0.01 ± 1.2, p < 0.01) and DAo peak velocity significantly increased (1.2 ± 0.3 m/s vs. 1.3 ± 0.3 m/s, p = 0.02) from initial to most recent TTE, respectively. No patient died or underwent an intervention on the LPA or DAo for stenosis. Seventy-five patients had a total of 208 repeat TTE > 1 year after PDA procedure with no change in clinical management.ConclusionsIn patients who underwent an uncomplicated PDA closure after infancy, TTE parameters improved or stayed within normal limits on the most recent TTE. Repeat lifetime TTEs after 1-year post-device placement in this population may not necessarily be needed if there are no clinical concerns. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Cardiology and Therapy Springer Journals

Utility of Follow-Up Echocardiograms in Uncomplicated PDA Device Closures Performed After Infancy

Loading next page...
 
/lp/springer-journals/utility-of-follow-up-echocardiograms-in-uncomplicated-pda-device-tSpZyJkHE2

References (31)

Publisher
Springer Journals
Copyright
Copyright © The Author(s) 2022
ISSN
2193-8261
eISSN
2193-6544
DOI
10.1007/s40119-022-00272-8
Publisher site
See Article on Publisher Site

Abstract

IntroductionGuidelines recommend lifelong follow-up with transthoracic echocardiograms (TTE) for patients who had a patent ductus arteriosus (PDA) device closure via catheterization. The goal of this study was to determine the utility of follow-up TTE in patients who underwent an uncomplicated PDA device closure after infancy.MethodsChart review was performed on patients who had a PDA closure ≥ 1 year of age between 1/1/2002 and 6/1/2020. Patients were excluded if they had other congenital heart disease, did not have a follow-up TTE ≥ 6 months after procedure, had a residual PDA or velocity > 2.0 m/s in the left pulmonary artery (LPA) or descending aorta (DAo) on the first TTE ≥ 6 months after device placement. Time points included the initial TTE after the procedure, first TTE ≥ 6 months after procedure, and the most recent TTE.ResultsA total of 189 patients met the study criteria. The median age and weight at initial procedure were 2.7 (1.0–64.7) years and 12.5 (3.4–69.2) kg. Most recent TTE was performed 2.0 (0.4–17.0) years after PDA closure. There were no significant differences in fractional shortening (36.4 ± 5.0% vs. 36.9 ± 5.6%) or LPA velocity (1.1 ± 0.4 m/s vs. 1.1 ± 0.4 m/s) from initial to most recent TTE, respectively. Left ventricular internal diastolic diameter Z-score significantly decreased (1.4 ± 1.8 vs. − 0.01 ± 1.2, p < 0.01) and DAo peak velocity significantly increased (1.2 ± 0.3 m/s vs. 1.3 ± 0.3 m/s, p = 0.02) from initial to most recent TTE, respectively. No patient died or underwent an intervention on the LPA or DAo for stenosis. Seventy-five patients had a total of 208 repeat TTE > 1 year after PDA procedure with no change in clinical management.ConclusionsIn patients who underwent an uncomplicated PDA closure after infancy, TTE parameters improved or stayed within normal limits on the most recent TTE. Repeat lifetime TTEs after 1-year post-device placement in this population may not necessarily be needed if there are no clinical concerns.

Journal

Cardiology and TherapySpringer Journals

Published: Sep 1, 2022

Keywords: Patent ductus arteriosus; Transthoracic echocardiogram; Echocardiogram

There are no references for this article.