Access the full text.
Sign up today, get DeepDyve free for 14 days.
B. Choudhary, Udayraj, Faming Wang, Y. Ke, Jie Yang (2020)
Development and experimental validation of a 3D numerical model based on CFD of the human torso wearing air ventilation clothingInternational Journal of Heat and Mass Transfer, 147
Wonseok Oh, S. Kato (2018)
The effect of airspeed and wind direction on human's thermal conditions and air distribution around the bodyBuilding and Environment
M. Yazdi, M. Sheikhzadeh (2014)
Personal cooling garments: a reviewThe Journal of The Textile Institute, 105
Dongliang Zhang, Yong-Jin Liu, Jin Wang, Jituo Li (2018)
An integrated method of 3D garment designThe Journal of The Textile Institute, 109
F. Salaün, É. Devaux, S. Bourbigot, P. Rumeau (2010)
Development of Phase Change Materials in Clothing Part I: Formulation of Microencapsulated Phase ChangeTextile Research Journal, 80
Shanchao Gao, R. Ooka, Wonseok Oh (2019)
Formulation of human body heat transfer coefficient under various ambient temperature, air speed and direction based on experiments and CFDBuilding and Environment
A. Hadid, A. Hadid, R. Yanovich, T. Erlich, Gennadi Khomenok, Daniel Moran (2008)
Effect of a personal ambient ventilation system on physiological strain during heat stress wearing a ballistic vestEuropean Journal of Applied Physiology, 104
Juhong Jia, Debin Fu, Zepeng He, Junfan Yang, Lijie Hu (2020)
Hypersonic aerodynamic interference investigation for a two-stage-to-orbit modelActa Astronautica, 168
N. Ismail, N. Ghaddar, K. Ghali (2019)
A Clothing Ventilation and Heat Loss Electric Circuit Model with Natural Convection for a Clothed Swinging Arm of a Walking HumanHeat Transfer Engineering, 40
Timothy Ernst, S. Garimella (2013)
Demonstration of a wearable cooling system for elevated ambient temperature duty personnelApplied Thermal Engineering, 60
Yijie Zhang, Juhong Jia (2020)
Numerical Investigation of Heat Transfer in Garment Air GapAutex Research Journal, 22
R. Cotta, K. Lisboa, M. Curi, S. Balabani, J. Quaresma, J. Pérez-Guerrero, E. Macêdo, N. Amorim (2019)
A review of hybrid integral transform solutions in fluid flow problems with heat or mass transfer and under Navier–Stokes equations formulationNumerical Heat Transfer, Part B: Fundamentals, 76
M. Barwood, P. Newton, M. Tipton (2009)
Ventilated vest and tolerance for intermittent exercise in hot, dry conditions with military clothing.Aviation, space, and environmental medicine, 80 4
M. Cho, Hyunsook Jung, H. Lee, Jinwon Lee (2016)
Simple formula for the non-uniform contaminant deposition on a cylindrical human body surrounded by porous clothingJournal of Mechanical Science and Technology, 30
N. Karim, S. Afroj, Kate Lloyd, Laura Oaten, D. Andreeva, C. Carr, A. Farmery, Il‐Doo Kim, K. Novoselov (2020)
Sustainable Personal Protective Clothing for Healthcare Applications: A ReviewACS Nano, 14
Ruihua Yang, Chao-yang Liu, Yuan Xue, Hongbo Wang, W. Gao (2016)
Numerical Analysis and Comparison of Airflow in Rotors with U and V Groove during Rotor Spinning ProcessJournal of Engineered Fibers and Fabrics, 11
Yuanliang Tang, Ying He, Hong-Wei Shao, C. Ji (2016)
Assessment of comfortable clothing thermal resistance using a multi-scale human thermoregulatory modelInternational Journal of Heat and Mass Transfer, 98
Jun Li, Zhaohua Zhang, Yunyi Wang (2013)
The relationship between air gap sizes and clothing heat transfer performanceThe Journal of The Textile Institute, 104
Yu Sun, W. Jasper (2015)
Numerical modeling of heat and moisture transfer in a wearable convective cooling system for human comfortBuilding and Environment, 93
Mengmeng Zhao, Chuansi Gao, Faming Wang, K. Kuklane, I. Holmér, Jun Li (2013)
A Study on Local Cooling of Garments with Ventilation Fans and Openings Placed at Different Torso SitesInternational Journal of Industrial Ergonomics, 43
Xiaojiang Xu, J. González (2011)
Determination of the cooling capacity for body ventilation systemEuropean Journal of Applied Physiology, 111
Dongliang Zhang, Jin Wang, Yuping Yang (2013)
Design 3D garments for scanned human bodiesJournal of Mechanical Science and Technology, 28
E. Mert, A. Psikuta, M. Bueno, R. Rossi (2015)
Effect of heterogenous and homogenous air gaps on dry heat loss through the garmentInternational Journal of Biometeorology, 59
G. Delkumburewatte, T. Dias (2012)
Wearable cooling system to manage heat in protective clothingThe Journal of The Textile Institute, 103
Sungmin Kim, C. Park (2007)
Basic garment pattern generation using geometric modeling methodInternational Journal of Clothing Science and Technology, 19
(2007)
Basic garment type generation using geometric modeling method
zyijie@usx.edu.cn Shangyu College, Shaoxing A personal microclimate management system is designed to maintain thermal comfort University, Shaoxing 312300, which allows people to overcome a harsh environment. It consists of several micro- Zhejiang, China Full list of author information fans placed in the garment side seam to provide cooling air. The computational fluid is available at the end of the dynamics method was used to simulate the three-dimensional model and analysis the article influence of fan’s number and air gap distance. The obtained results depict that the introduced cool airflow will find its way along paths with flow resistance minimized and exhaust through several separated exit. The body heat flux is taken away at the same time. The convection effect is enhanced by the increase in the fans’ numbers, but the fans’ cooling effect varies a lot because of various air gap distances. When the air gap is small enough, the cooling air impact the body surface directly and causes fierce heat loss. While the air gap distance is large enough, the heat transfer along the skin surface could be enhanced by the eddy flow which is existed in the air gap between body and garment. These phenomena can maintain the body’s thermal comfort in a suitable range. Keywords: Clothing microclimates, Human thermal comfort, Wearable cooling system, Convective heat transfer, CFD Introduction With the continuous spread of COVID-19, medical, community workers, and volunteers during their duties may be exposed to polluted air (Karim et al., 2020). They may also come into direct contact with patients and potential virus carriers. Therefore, special protective garments are widely used to block transmission. However, these tight, closed spaces between protective clothing and body surface make against human body heat dissipations and cause discomfort microclimate under clothing (Tang et al., 2016). The ordinary clothes are provided with holes for ventilation and heat dissipation, but this goal gains at the expense of losing security. A more acceptable way would be to design a personal microclimate management system to maintain thermal comfort which allows people to overcome a harsh environment (Cho et al., 2016). Such a system should main- tain a comfortable microclimate, as well as filter and purify the inflow air. Moreover, the system should be user-controlled to adjust the ventilation rate in the air gap between the body and clothing. © The Author(s) 2021. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the mate- rial. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/. Zhang et al. Fashion and Textiles (2022) 9:2 Page 2 of 14 The human body generates heat energy from the process of metabolism and body movements. While wearing ordinary work clothes, heat flux is lost easily from breath - able cloth due to the high temperature gradient between the human body and ambi- ent environment (Xu & Gonzalez, 2011). But under the closed protective clothing, the thermal energy is reserved in small air gap spaces because of airtight fabric. So, garment cooling measures must be considered to prevent thermal discomfort, excessive sweating even heat stroke results from the increase in human core body temperature. Since clothing always remains close to the body even during dynamic motions, the portability of the air ventilation system is more advantageous. The portable garment cooling method can be classified into two categories: phase change garments and forced air exchanger garments. In phase change garments, the cooling effect result from the heat absorption by the melting of phase change materials (Salaun et al., 2010). Therefore, the cooling efficiency decreasing as the phase change material is melting. Furthermore, it is a difficult problem for the store and transmission of phase change materials, not to mention reusability. In a forced air exchange cooling system, some air exchange fans are installed on the garment surfaces, and heat loss occurs by convective heat transfer as well as evaporative moisture transfer (Delkumburewatte & Dias, 2012). Compared with the phase change system, the forced air exchange system has the advantage of relatively high cooling capacity and reusability. Besides, the simple manufacturing process and low cost are also its superiorities (Ernst & Garmella, 2013). Previous studies showed that wearable air ventilation systems are effective enough till as high as 40 °C (Hadid et al., 2008) and 45 °C (Barwood et al., 2009) environmen- tal temperatures. Some design modifications of air ventilation clothing by moving the fan locations and providing openings at appropriate locations were tried to improve the cooling performance (Zhao et al., 2013). The space between the skin and the clothing, i.e. the air gap, plays an important role in heat and mass transfer. Li et al. (2013) estab- lished a relationship between air gap thickness and heat transfer using 3D scanning and human body temperature data. Mert et al. (2015) studied the effect of heterogeneous and homogenous air gaps on dry heat loss through the garment by scanned cloud data. These experimental analyses, however, have some shortcomings because of the lack of three-dimensional distribution characters, which may bring about significant local vari - ations. The computational fluid dynamics (CFD) method, with the ability to simulate 3D temperature and velocity fields, has become an essential tool in the prediction of ther - mal comfort of protective garments cooling systems (Zhang & Jia, 2021). Meanwhile, heat transfer and mass transfer can be acquired by solving the coupled multiple transfer model equations. Sun and Jasper (2015) investigated a 2D cooling system consists of a series of micro-fans, placed in a ribbon and attached to a garment. They argued that this convective cooling system significantly improved the convective and evaporative heat transfer coefficients when the inlet airflows were at 0.75 m/s and 1 m/s. Choudhary et al. (2019) developed a three-dimensional air ventilation cooling model to determine heat transfer between the human body and the environment by numerical simulation. The result showed that the area-weighted average torso heat flux increased while the fan air - flow rate increased. The above studies proved that the heat convection on body skin is highly affected by airflow conditions, such as air velocity, wind direction, turbulence eddies. To the best of Zhang et al. Fashion and Textiles (2022) 9:2 Page 3 of 14 our knowledge, few reports comprehensively describe the distribution and mechanism of airflow conditions between three-dimensional body skin and garment surface. In this research, a wearable convective cooling system composed of several micro-fans is pro- posed, then, the temperature and heat flux distributions, as well as flow mechanism are analyzed. Methods Model development A 3D avatar is used in the assessment of thermal comfort under different conditions. The female body is established by CLO Standalone (CLO Virtual Fashion Inc, Korea), with a height of 166 cm and bust, waist and hip girth length of 86, 66 and 90 cm, as shown in Fig. 1a. A fitted X-type garment is constructed by Bezier-spine curves. First, the body surface feature points are extracted and used to obtain corresponding garment feature points by adding air gap distance. Then, these garment feature points are used to construct garment surfaces by Bezier-spine curves (Zhang et al., 2014, 2018). The flatten garment pattern is shown in Fig. 2c. A wearable cooling system, consists of a series of fil - tered micro-fans with diameters of 2 cm, is embedded in the side seam of the protective garment. These fans connect to a potable lithium battery. This convective cooling system is expected to matain the thermal comfort in the hazardous environment. The Ansys ICEM-CFD (ANSYS Inc., Canonsburg, PA, USA) was used to generate an unstructured mesh in the computational domain by the robust Octree method. All the body and gar- ment surfaces meshed with triangular surface mesh (Fig. 2d). Eight inflation layers were also generated along the body surface to capture the near wall temperature gradient cor- rectly. It is to be noted here that only half-geometry was taken into consideration in this study due to the symmetric, and treated as the computational domain. Governing equations A computational fluid dynamics approach was used to perform three dimensional transient simulations of flow and heat transfer through the microclimate involving air ventilation system. Some of the important simplifications and assumptions consid - ered in the present study are as follows (Ismail et al., 2019; Oh & Kato, 2018): Firstly, we assume that the present model deals with dry conditions without sweating, i.e. we focus on convective heat transfer rather than evaporative heat transfer. Secondly, the (a) (b) (c) (d) Fig. 1 3D model and boundary conditions. a Geometry model, b garment type and boundaries, c garment pattern, d mesh domain Zhang et al. Fashion and Textiles (2022) 9:2 Page 4 of 14 FKHVWIURQWGHQV H FKHVWEDFNGHQVH FKHVWIURQWPHGLX P FKHVWEDFNPHGLX P FKHVWIURQWFRDUV H FKHVWEDFNFRDUV H ;P (a) (b) 5HIHUHQFH 3UHVHQWUHVXOW &RQYHFWLYHKHDWWUDQVIHUFRHIILFLHQW:P KXPDQERG\VXUIDFHPP (c) (d) Fig. 2 Mesh independence check and method evaluation. a The contours of y+ on body surface, b grid convergence tests, c wearable convective cooling system, d model validation with public results protective garment was considered air-tight, the air flows in from the micro-fans and goes out through collar, sleeves and hem. Thirdly, we also assume turbulent incom - pressible flow with ideal gas, as well as the no-slip boundary condition for the wall surface. The Boussinesq approximation was used to calculate the buoyancy effect, and realizable k–ɛ model was used to deal with the turbulence effect. With these assumptions, the governing Reynolds-averaged equations are summa- rized below (Renato et al., 2019): Continuity equation: (ρu ) = 0 (1) ∂x Momentum equation: ∂(ρu u ) ∂p ∂ ∂u ∂u i j i j ∗ ∗ =− + μ + − ρu u +ρβ(T − T )g 0 i (2) i j ∂x ∂x ∂x ∂x ∂x j i j j i 7. Zhang et al. Fashion and Textiles (2022) 9:2 Page 5 of 14 Energy equation: ∂(ρu c T ) ∂ ∂T i p =− k + ρu c T i p ∂x ∂x ∂x i i i The k–ɛ turbulence model is described by the turbulent kinetic energy k and its dissi- pation rate ɛ, which can be expressed as follows (Yang et al., 2016): ∂ ∂ μ ∂k μ ∂u ∂u t t i (ρku ) = μ + + + − ρε (4) ∂x ∂x σ ∂x 2 ∂x ∂x i j j j i ∂ ∂ μ ∂ε ε μ ∂u ∂u ε t t i j (ρεu ) = μ + + C + − C ρ i 1ε 2ε (5) ∂x ∂x σ ∂x k 2 ∂x ∂x k i j ε j j i where, the viscosities turbulence coefficient μ is defined as μ = ρC , and C = 0.09, C = 1.44, C = 1.92, σ = 1, σ = 1.3. t μ μ 1ε 2ε k ε Boundary conditions and technical approaches The boundary conditions are shown in Fig. 1b. The micro-fans are considered as air - flow inlet, and the air gaps of armhole and neckline are considered as air outflow. The human body is set as isothermal wall, the body skin surface temperature was fixed at 36 °C/309 K. At the inlet, so as to investigate the heat transfer in the microclimate of protective clothing, forced convection in a normal atmospheric environment, ambient temperature of 20 ℃/293 K, was modeled by considering air flowing through micro-fans then reach the body surface. The velocity was kept constant at 0.5 m/s, and the relative humidity was maintained at 40%. The following calculations were performed under dry conditions (i.e. no sweating). A no-slip condition at the surface of the garment and body skin was imposed. The thermal conductivity of air and body are considered as 0.026 and 0.3 W/(m K). The convective heat transfer from the outside of the garment to the envi - ronment was also considered and treated as a typical natural convection condition. This heat loss coefficient was taken as 5 W/m K. The textile consisted of a 100% cotton fabric layer of thickness 0.204 mm, and the physical properties were obtained from published results (Sun & Jasper, 2015). The detailed physical properties and boundary conditions are shown in Table 1. The above mentioned mathematical equations were solved at each node of the com - putational domain by using the finite volume method (FVM). A second order upwind scheme for all the pressure, momentum, turbulence and energy equations were used for discretization with a multidimensional total variation diminishing flux limiter (Jia et al., 2020). Finite volume method based commercial CFD solver CFD++ (Metacomp Tech- nologies Inc, USA) was used to obtain the numerical results. Double precision format was used for all kinds of computations and the converged residual level was set to below –5 1 × 10 . Zhang et al. Fashion and Textiles (2022) 9:2 Page 6 of 14 Table 1 Physical properties and boundary conditions Medium Boundary types Physical properties Thermal Pressure constant conductivity thermal capacity (W/K m) (J/K kg) Inlet Air Uniform inlet flow p = 101325 pa 0.026 1000 air T = 283 K air v = 0.5 m/s air ρ = 1.165 kg/m air Outlet Air Back pressure outlet p = 101325 pa – – out Body surface Human skin Isothermal wall T = 310 K 0.3 5021 skin ρ = 860 kg/m skin Garment Cotton Convection wall ρ = 81 kg/m 0.059 1150 cottom Methodologies evaluation The nondimensional near wall distance y +, which express as y =ρu y /μ , w a s τ wall used to measure the first grid cell above the wall. As can see in Fig. 2a, the near wall y+ was less than 1.0 for all most of the human body surface. At this time, the first grid cell was located within the viscous sublayer (Jia et al., 2020). Grid independence on cooling performance of micro-fan system was analyzed with three levels of mesh refinement, namely 3.2 million (coarse), 3.7 million (medium) and 4.2 million nodes (dense). The results were shown in Fig. 2b, it can be observed from the mesh check study that the dense grid is enough to resolve the heat transfer of the micro-fan cool- ing system. The numerical method is validated first against the available results (Sun & Jasper, 2015) for a two dimensional wearable convective cooling system, in which a series of micro-fans installed in a ribbon and attached to clothing, as shown in Fig. 2c. The convective heat transfer coefficient was obtained and compared with public results. The comparison study shows that the present work is agrees with the available results well. So, it would be satisfactory to carry out the following calculations under the above conditions. Results and Discussion With the aim of analyzing the temperature and heat transfer distribution in detail, four parallel cross-sections were created, namely the chest, bust, waist and hip hori- zontal planes. Then, the key girths were generated as the intersections of plane and body surface, as shown in Fig. 3a. The Cartesian coordinates are fixed to the symme - try plane, and the X, Y, Z refers to the horizontal, vertical and radial distance. Three different types of calculations were carried out to study the heat exchange between the body and clothing and to determine heat flux quantitatively along the skin surface, as: (1) one was comprised of double 2 cm diameter fans, namely the fans of No. 3 and No. 7, located in the lower bust and waist with a distance of 18 cm; (2) the second was comprised of four 2 cm fans, i.e., the fans of No. 1, No. 3, No. 5 and No. 7, located in the lower armpit, bust, waist and hip with the distance of 8, 9, and 14 cm and (3) the third was comprised of eight 2 cm fans (No. 1 to No. 8) located in lower armpit, bust, waist and hip with the distance of 3.5, triple 4.5, 5.5, 6.5, 7.5 and 10 cm on the garment surface. The fan’s type and numbers are shown in Table 2. The Zhang et al. Fashion and Textiles (2022) 9:2 Page 7 of 14 (a) (b) Fig. 3 Landmarks and air gap. a Horizontal cross-section and cut lines, b air gap distance contours Table 2 Calculation conditions Cases Fan type Inlet airflow Micro-fans Numbers Space between fans (cm) (m/s) Case 1 2 0.5 2 No. 3, No. 7 18 cm Case 2 2 0.5 4 No. 1, No. 3, No. 5 8, 9, and 14 cm and No. 7 Case 3 2 0.5 8 No. 1 to No. 8 3.5 cm, triple 4.5 cm, 5.5 cm, 6.5 cm, 7.5 cm and 10 cm ambient air temperature is 283 K and the inflow air is transfer through micro-fans with a constant velocity of 0.5 m/s. Three dimensional air gap distributions The 3D air gap contours are shown in Fig. 3b. As shown, the neckline, side bust and waist yield a narrow air gap of less than 5 mm because the clothing is closed to the body surface. Meanwhile, the underbust and groin region have a large air gap distance due to the structure of the human body. The detailed air gap distributions on body key girth are shown in Fig. 4. As can see in Fig. 4a, the curves of the chest and bust girth go down along the body surface on the front side. However, the trend of the hip front girth curve is increasing at first and then decreasing. The reason is that this region is nearby the area of the human body groin. Figure 4b shows the scene of body backside, the air gap is keep decreasing on the whole, but the distance is bigger than that on the front side. Temperature distributions on garment surface The simulated temperature contours of different micro-fans configurations are shown in Fig. 5. As can see, there are several high temperature regions on the clothing surface near the neckline, armpit, waist and thigh under the natural convection condition. The $LUJDSP $LUJDSP Zhang et al. Fashion and Textiles (2022) 9:2 Page 8 of 14 &KHVWEDF N &KHVWIURQ W %XVWEDFN %XVWIURQW :DLVWEDF N :DLVWIURQ W +LSEDF N +LSIURQ W (a)(b) Fig. 4 Air gap distance distributions. a Air gap distance of front side, b air gap distance of back side reason is that the above mentioned area is narrow enough so that the heat flux transfer from the body to the clothing surface easily. But Fig. 5a–c show different scene because of forced heat flux convection by micro-fans. Firstly, if there are just two separated micro- fans installed on the garment which are located at the lower bust and upper thigh (Fig. 5b), there are other two high temperature areas appear around the micro-fans. Meanwhile, there is a big high temperature region on the thigh girth near the fan, the reason is mainly that part of the inlet air flows reflected the garment surface due to the narrow air gap dis - tance, as can see in Fig. 3b. Secondly, if there are four micro-fans located at the armpit, underbust, waist and upper hip (Fig. 5c), the high temperature regions become bigger and the peak value increase to a new level and the area near the fourth fan keeps at a low level because of a big air gap distance. Thirdly, if the number of micro-fans increased to eight, there are several anomaly high temperature regions around No. 1 to No. 6 fans because of the narrow and uneven air gap. However, the high temperature regions are not so appar- ently around the last two fans because of wide air gap. In order to analyze the temperature quantitatively, the detailed temperature distri- butions on key girths are exhibited in Fig. 6. As is shown in Fig. 6a, the temperature distributions on the chest girth garment surface increase with the horizontal distance nonlinear. The case of two fans yield the lowest temperature on the both side of garment surface, while the model with eight fans obtains the highest temperature, especially on the back side. Figure 6b shows that, the temperature curves on the bust girth of three cases keep pace with each other on the whole, except at the location of armpit. On the armpit area, the temperature curves rise up quickly and reach about 299.5 K for case 3, 298.6 K for case 2 and 296.8 K for case 1. This phenomenon mainly due to the combined action of narrow distance and quickly flow speed of outflow. Figure 6c depicts that the temperature curves show a wavelike appearance on the waist girth, especially between the section of 0.1 m < x < 0.12 m. To be specific, there is a plateau region on the tempera - ture curve of case 1, but there are two high peaks for case 2 and 3 where the temperature reach to 295.9 K and 296.8 K. As can see in Fig. 6d, there show different scene for front side and back side. The temperature curves of back hip side increase to high values in the middle but decrease to lower values at the end. However, the temperature curves of front hip side decrease to a low level at the middle due to large air gap distance, but ;P ;P 7. 7. Zhang et al. Fashion and Textiles (2022) 9:2 Page 9 of 14 Fig. 5 Temperature contours under various micro-fans type. a Case 1, 2 fans, b case 2, 4 fans, c case 3, 8 fans FKHVWIURQWFDVH EXVWIURQWFDVH FKHVWEDFNFDV H EXVWEDFNFDV H FKHVWIURQWFDVH EXVWIURQWFDVH FKHVWEDFNFDV H EXVWEDFNFDV H FKHVWIURQWFDVH EXVWIURQWFDVH FKHVWEDFNFDV H EXVWEDFNFDV H ;P (a) (b) KLSIURQWFDVH ZDLVWIURQWFDVH KLSEDFNFDVH ZDLVWIURQWFDVH KLSIURQWFDVH ZDLVWIURQWFDVH KLSEDFNFDVH ZDLVWIURQWFDVH KLSIURQWFDVH ZDLVWEDFNFDVH KLSEDFNFDVH ZDLVWIURQWFDVH 7. ;P (c) (d) Fig. 6 Temperature distribution on garment surface. a Chest girth, b bust girth, c waist girth, d hip girth increase to high number near the side part because of forced convection of micro-fans. Moreover, the convection effect is enhanced by the increase the number of fans. 7. ;P ;P Zhang et al. Fashion and Textiles (2022) 9:2 Page 10 of 14 (a) (b) (c) Fig. 7 Heat flux contours for different cases. a Case 1, two fans, b case 2, four fans, c case 3, eight fans Heat transfer on body surface The conductive and convective heat transfer coefficients for an environmental temperature of 20 °C according to simulation are given in Fig. 7. Predictably, the heat transfer distribu- tion on the body surface is strongly related to the inflow air from micro-fans. Only a small portion of body surface is covered by micro-fan, but a large high heat flux area is around it due to three dimensional airflow. As can see in Fig. 7a, under the circumstance of case 1, because of the forced convective heat transfer, there are two high heat flux regions around 2 2 the micro-fans, and each of them has a peak value of about 85 W/m and 60 W/m . Besides, there is also a high heat flux region on the top of the shoulder, mainly due to the conductive in air gap. For case 2 in Fig. 7b, there are four different high heat flux regions around the micro-fan holes, and each of them has a heat spot corresponding to the micro-fans inlet air flow. As for case 3 in Fig. 7c, eight high heat flux regions next to each other along the side seam. It is interesting to note that the high heat spots area show a scattered appearance, and the location of the high heat spot is offset from the original position on the waist and thigh part of the body. This phenomenon will be further explored in detail in followed chapter. In order to investigate the heat transfer performance quantitatively, the heat transfer coefficients on key girths are shown in Fig. 8. The average heat transfer on chest girth, 2 2 in Fig. 8a, is about 27 W/m K on the back side and 28.5 W/m K on the front side. The heat flux curves have a plateau on the front side and a peak on the back side for all the three types of micro-fans, and the heat transfer coefficients are higher for more fans, as case 3 yield the highest peak value of 29.4 W/m K. Figure 8b depicts that the case of more fans model gains a bigger heat flux on the bust girth, especially on the position near the fans. Figure 8c indicates that the variety of fans number has less influence on the waist girth of 0 m < x < 0.75 m, for the heat transfer coefficient almost keeps the same for different models. But the area near the micro-fan inlet flow has a totally different scene, the curves have sinusoid shape for four and eight fan models. The fans locations correspond to the peak values of convective heat transfer coefficient in these regions. Figure 8d shows that the heat flux keep at a low level of about 26 W/m K for the front side and 27 W/m K for the back side on most of the hip area. But due to the forced con- vection, the area near the fans yields a peak value of more than 27 W/m K for the eight . & . RHI: WUDQ RHI: RHI: 7UDQ +HDW Zhang et al. Fashion and Textiles (2022) 9:2 Page 11 of 14 EXVWIURQWFDVH EXVWEDFNFDVH EXVWIURQWFDVH EXVWEDFNFDVH P EXVWIURQWFDVH EXVWEDFNFDVH &KHVWIURQWFDVH &KHVWEDFNFDVH &KHVWIURQWFDVH &KHVWEDFNFDVH &KHVWIURQWFDVH &KHVWEDFNFDVH ;P (a) (b) ZDLVW IURQWFDVH KLSIURQWFDVH KLSEDFNFDVH ZDLVW EDFNFDVH KLSIURQWFDVH ZDLVW IURQWFDVH ZDLVW EDFNFDVH KLSEDFNFDVH P KLSIURQWFDVH ZDLVW IURQWFDVH KLSEDFNFDVH ZDLVW EDFNFDVH RHI: (c) (d) Fig. 8 Heat transfer coefficient distribution on body surface. a Chest girth, b bust girth, c waist girth, d hip girth Fig. 9 Air flow contours of air gap and body surface fans model. From the above analysis, we find that the micro-fan brings fierce convec - tion and large heat loss around the fan holes. The heat transfer strength is highly related to the fan numbers. However, the influence of forced convection is decreased while the location keeps away from the fans mainly due to the low efficiency air ventilation in the complex air gap. Flow mechanism analysis To illustrate the airflow properties and eddies formed near the skin surface. The local velocity profile is obtained and shown in Fig. 9. As can see, the cooling air from micro- fan gives rise to the high speed airflow in the area around the fans. These flows carry the V& . +HDW WUDQ V& . +HDW V& +HDW7 UDQV ;P ;P ;P Zhang et al. Fashion and Textiles (2022) 9:2 Page 12 of 14 Fig. 10 Parallel flats model (a)(b) Fig. 11 Regional air flow contours under different air gap distance. a Air flow contours with 30 mm air gap, b air flow contours with 5 mm air gap heat flux from body surface and reach the garment surface. This action will bring about the temperature rise on garment surface. However, the air velocity goes down quickly while the location moves far away from the fans. So, the air ventilation efficiency in these regions is very poor, as has been predicted above. With the aim of investigating the detailed flow mechanism, the airflow between two parallel flats is computed to simulate the body and garment surfaces with the air gap dis - tance of 30 mm and 5 mm, as shown in Fig. 10. There are several micro-fans installed on the first flat with a diameter of 2 cm. The boundary conditions are set to be the same as the human body model. The calculated airflow speed contours are shown in Fig. 11. As can see in Fig. 11a, when the air gap distance is large enough, i.e., 30 mm, the cooling air will flow through the fan and reach the skin surface, then two eddy vertexes are created in the air gap. The air speed in eddies is relatively slow, so it would cause a small part of heat transfer loss on body surface. However, when the air gap distance is small enough, namely 5 mm, as shown in Fig. 11b, the inflow will impact the body surface, then it is separated into several sub-flows in different directions. These sub-flows from dif - ferent fans may interact with each other and cause several high speed areas on the body surface. Meanwhile, this fierce impact brings about high heat loss on the body Zhang et al. Fashion and Textiles (2022) 9:2 Page 13 of 14 surface. This phenomenon can maintain a lower body surface temperature, but fails to maintain a comfortable micro-environment. Conclusions With the aim of keeping thermal comfort in a harsh environment, a concept of a light- weight wearable convective cooling system is investigated. This system consists of a series of filtered micro-fans which is embedded in side seam of the protective garment. Three different configurations, namely two, four or eight 2 cm micro-fans models, were analyzed. Three dimensional heat transfer at the body surface was simulated with the inflow air speed of 0.5 m/s. The main conclusions are as follows: The installment of micro-fans is a feasible way that can maintain a comfortable micro - climate under protective garments. The air flow finds its way along paths with flow resistance minimized and takes away the body heat flux. The micro-fan brings fierce convection and large heat loss around the fan holes and the convection effect is enhanced by the increase of the fans numbers. However, the influence of forced convection is decreased while keeps away from the fans hole due to the low efficiency air ventilation in the complex air gap. When the air gap is small enough, the cooling air impact the body surface directly and cause fierce heat loss. At this time, the thermal comfort would goes down to some extent. When the air gap distance is large enough, the heat transfer along the skin surface could be enhanced by the eddy flow which is existed in the air gap between body and garment. Under this circumstance, thermal comfort can be improved to a large extent. Acknowledgements Not applicable. Authors’ contributions YZ contributed to conception and design of the study. JJ carried out CFD analyses. ZG drafted manuscript. All authors read and approved final manuscript. Authors’ informations Yijie Zhang, Ph.D., Lecturer, Shangyu College, Shaoxing University, Shaoxing, Zhejiang 312300, China. Ziyi Guo, Ph.D. student. School of Fashion Design and Engineering, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, China. Juhong Jia, Engineer, School of Aerospace Engineering, Beijing Institute of Technology, Beijing, 100081, China. Funding Not applicable. Availability of data and materials Not applicable. Declarations Competing interests The authors declare that they have no competing interest. Author details 1 2 Shangyu College, Shaoxing University, Shaoxing 312300, Zhejiang, China. School of Fashion Design and Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, Zhejiang, China. School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081, China. Received: 16 July 2021 Accepted: 24 August 2021 Zhang et al. Fashion and Textiles (2022) 9:2 Page 14 of 14 References Barwood, M. J., Newton, P. S., & Tipton, M. J. (2009). Ventilated vest and tolerance for intermittent exercise in hot, dry conditions with military clothing. Aviation Space & Environmental Medicine, 80(4), 353–359. https:// doi. org/ 10. 3357/ ASEM. 2411. 2009. Cho, M. K., Jung, H., Lee, H. W., & Lee, J. W. (2016). Simple formula for the non-uniform contaminant deposition on a cylin- drical human body surrounded by porous clothing. Journal of Mechanical Science and Technology, 30(4), 1595–1601. https:// doi. org/ 10. 1007/ s12206- 016- 0314-3. Choudhary, B., Wang, U. F., et al. (2019). Development and experimental validation of a 3d numerical model based on CFD of the human torso wearing air ventilation clothing. International Journal of Heat and Mass Transfer, 147(2), 1–11. https:// doi. org/ 10. 1016/j. ijhea tmass trans fer. 2019. 118973. Delkumburewatte, G. B., & Dias, T. (2012). Wearable cooling system to manage heat in protective clothing. The Journal of the Textile Institute, 103(5), 483–489. https:// doi. org/ 10. 1080/ 00405 000. 2011. 587647. Ernst, T. C., & Garmella, S. (2013). Demonstration of a wearable cooling system for elevated ambient temperature duty personnel. Applied Thermal Engineering, 60(2), 316–324. https:// doi. org/ 10. 1016/j. applt herma leng. 2013. 06. 019. Gao, S., Ookab, R., & Oh, W. (2019). Formulation of human body heat transfer coefficient under various ambient tempera- ture, air speed and direction based on experiments and CFD. Building and Environment, 160(8), 1–17. https:// doi. org/ 10. 1016/j. build env. 2019. 106168 Hadid, A., Yanovich, R., Erlich, T., et al. (2008). Eec ff t of a personal ambient ventilation system on physiological strain dur - ing heat stress wearing a ballistic vest. European Journal of Applied Physiology, 104, 311–319. https:// doi. org/ 10. 1007/ s00421- 008- 0716-8. Ismail, N., Ghaddar, N., & Ghali, K. (2019). A clothing ventilation and heat loss electric circuit model with natural convec- tion for a clothed swinging arm of a walking human. Heat Transfer Engineering, 2, 330–345. https:// doi. org/ 10. 1080/ 01457 632. 2018. 14290 55. Jia, J. H., Fu, D. B., He, Z. P., et al. (2020). Hypersonic aerodynamic interference investigation for a two-stage-to-orbit model. Acta Astronautica, 168, 138–145. https:// doi. org/ 10. 1016/j. actaa stro. 2019. 11. 038. Karim, N., Afroj, S., Lloyd, K., et al. (2020). Sustainable personal protective clothing for healthcare applications: A review. ACS Nano, 168(10), 12313–12340. https:// doi. org/ 10. 1021/ acsna no. 0c055 37. Kim, S. M., & Park, C. K. (2007). Basic garment type generation using geometric modeling method. International Journal of Clothing Science and Technology, 19(1), 7–17. https:// doi. org/ 10. 1108/ 09556 22071 07170 17. Li, J., Zhang, Z., & Wang, Y. (2013). The relationship between air gap sizes and clothing heat transfer performance. The Journal of the Textile Institute, 104(12), 1327–1336. https:// doi. org/ 10. 1080/ 00405 000. 2013. 802080. Mert, E., Psikuta, A., Bueno, M. A., et al. (2015). Eec ff t of heterogenous and homogenous air gaps on dry heat loss through the garment. International Journal of Biometeorology, 59(11), 1701–1710. https:// doi. org/ 10. 1007/ s00484- 015- 0978-x. Oh, W., & Kato, S. (2018). The effect of airspeed and wind direction on human’s thermal conditions and air distribution around the body. Building and Environment, 141, 103–116. https:// doi. org/ 10. 1016/j. build env. 2018. 05. 052. Renato, M. C., Kleber, M. L., & Marcos, F. C. (2019). A review of hybrid integral transform solutions in fluid flow problems with heat or mass transfer and under Navier-Stokes equations formulation. Numerical Heat Transfer Fundamentals, 4, 1–28. https:// doi. org/ 10. 1080/ 10407 790. 2019. 16427 15. Salaun, F., Devaux, E., Bourbigot, S., & Rumeau, P. (2010). Development of phase change materials in clothing part I: Formulation of microencapsulated phase change. Textile Research Journal, 80(3), 195–205. https:// doi. org/ 10. 1177/ 00405 17509 093436. Sun, Y., & Jasper, W. J. (2015). Numerical modeling of heat and moisture transfer in a wearable convective cooling system for human comfort. Building and Environment, 93(2), 50–62. https:// doi. org/ 10. 1016/j. build env. 2015. 06. 008. Tang, Y., He, Y., Shao, H., & Ji, C. (2016). Assessment of comfortable clothing thermal resistance using a multi-scale human thermoregulatory model. International Journal of Heat & Mass Transfer, 98(7), 568–583. https:// doi. org/ 10. 1016/j. ijhea tmass trans fer. 2016. 03. 030. Xu, X., & Gonzalez, J. (2011). Determination of the cooling capacity for body ventilation system. European Journal of Applied Physiology, 111(21), 3155–5160. https:// doi. org/ 10. 1007/ s00421- 011- 1941-0. Yang, R. H., Liu, C., Xue, Y., et al. (2016). Numerical analysis and comparison of airflow in rotors with U and V groove during rotor spinning process. Journal of Engineered Fibers & Fabrics, 11(4), 29–35. https:// doi. org/ 10. 1177/ 15589 25016 01100 Yazdi, M. M., & Sheikhzadeh, M. (2014). Personal cooling garments: A review. The Journal of the Textile Institute, 105(12), 1231–1250. https:// doi. org/ 10. 1080/ 00405 000. 2014. 895088. Zhang, D. L., Wang, J., & Yang, Y. P. (2014) Design 3D garments for scanned human bodies. Journal of Mechanical Science & Technology, 28(7), 2479–2487. https:// doi. org/ 10. 1007/ s12206- 014- 0605-5. Zhang, D., Liu, Y., Wang, J., et al. (2018). An integrated method of 3D garment design. The Journal of the Textile Institute, 109(12), 1595–1605. https:// doi. org/ 10. 1080/ 00405 000. 2018. 14366 38. Zhang, Y. J., & Jia, J. H. (2021). Numerical investigation of heat transfer in garment air gap. AUTEX Research Journal, 21, 1–8. https:// doi. org/ 10. 2478/ aut- 2020- 0055 Zhao, M., Gao, C., Wang, F., et al. (2013). A study on local cooling of garments with ventilation fans and openings placed at different torso sites. International Journal of Industrial Ergonomics, 43, 232–237. https:// doi. org/ 10. 1016/j. ergon. 2013. 01. 001. Publisher’s Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Fashion and Textiles – Springer Journals
Published: Jan 15, 2022
Keywords: Clothing microclimates; Human thermal comfort; Wearable cooling system; Convective heat transfer; CFD
You can share this free article with as many people as you like with the url below! We hope you enjoy this feature!
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.