Nonlinear numerical analysis of a flexible rotor equipped with squeeze couple stress fluid film journal bearings

Nonlinear numerical analysis of a flexible rotor equipped with squeeze couple stress fluid film... Abstract This study performs a dynamic analysis of a rotor supported by two squeeze couple stress fluid film journal bearings with nonlinear suspension. The numerical results show that the stability of the system varies with the non-dimensional speed ratios and the dimensionless parameter l*. It is found that the system is more stable with higher dimensionless parameter l*. Thus it can conclude that the rotor-bearing system lubricated with the couple stress fluid is more stable than that with the conventional Newtonian fluid. The modeling results thus obtained by using the method proposed in this paper can be used to predict the stability of the rotor-bearing system and the undesirable behavior of the rotor and bearing center can be avoided. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png "Acta Mechanica Solida Sinica" Springer Journals

Nonlinear numerical analysis of a flexible rotor equipped with squeeze couple stress fluid film journal bearings

Loading next page...
 
/lp/springer-journals/nonlinear-numerical-analysis-of-a-flexible-rotor-equipped-with-squeeze-AFpv8iotDJ
Publisher
Springer Journals
Copyright
2007 The Chinese Society of Theoretical and Applied Mechanics and Technology
ISSN
0894-9166
eISSN
1860-2134
DOI
10.1007/s10338-007-0736-7
Publisher site
See Article on Publisher Site

Abstract

Abstract This study performs a dynamic analysis of a rotor supported by two squeeze couple stress fluid film journal bearings with nonlinear suspension. The numerical results show that the stability of the system varies with the non-dimensional speed ratios and the dimensionless parameter l*. It is found that the system is more stable with higher dimensionless parameter l*. Thus it can conclude that the rotor-bearing system lubricated with the couple stress fluid is more stable than that with the conventional Newtonian fluid. The modeling results thus obtained by using the method proposed in this paper can be used to predict the stability of the rotor-bearing system and the undesirable behavior of the rotor and bearing center can be avoided.

Journal

"Acta Mechanica Solida Sinica"Springer Journals

Published: Dec 1, 2007

Keywords: Theoretical and Applied Mechanics; Surfaces and Interfaces, Thin Films; Classical Mechanics

References