Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Improved and new calculation schemes for coke batteries

Improved and new calculation schemes for coke batteries ISSN 1068-364X, Coke and Chemistry, 2007, Vol. 50, No. 3, pp. 63–66. © Allerton Press, Inc., 2007. Original Russian Text © V.S. Romas’ko, 2007, published in Koks i Khimiya, 2007, No. 3, pp. 20–23. COKE V. S. Romas’ko Kharkov State Technical University of Construction and Architecture, Ukraine DOI: 10.3103/S1068364X07030040 Discussions of coke-battery design in this journal damentally impossible to construct a calculation scheme have covered a wide range of topics associated with permitting estimation of the stress state of the heating simplified description of its geometric properties, wall’s refractory lining, since it does not withstand ten- thanks to the reduction of the three-dimensional struc- sile stress and compression of the lining by additional ture to a one-dimensional beam scheme. For example, forces to fully compensate the tensile stress from flex- in selecting the calculation scheme for the heating wall ure is impossible. of a coke furnace, the properties of the coal batch and The carrying capacity of the wall is determined on the the carrying capacity of the heating wall are taken into basis of the limiting value q of the transverse-load inten- account in simulating the load on the structure. lim sity q above which cracks appear in http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Coke and Chemistry Springer Journals

Improved and new calculation schemes for coke batteries

Coke and Chemistry , Volume 50 (3) – Jul 3, 2007

Loading next page...
 
/lp/springer-journals/improved-and-new-calculation-schemes-for-coke-batteries-pyohXHUpfi
Publisher
Springer Journals
Copyright
Copyright © 2007 by Allerton Press, Inc.
Subject
Chemistry; Industrial Chemistry/Chemical Engineering
ISSN
1068-364X
eISSN
1934-8398
DOI
10.3103/S1068364X07030040
Publisher site
See Article on Publisher Site

Abstract

ISSN 1068-364X, Coke and Chemistry, 2007, Vol. 50, No. 3, pp. 63–66. © Allerton Press, Inc., 2007. Original Russian Text © V.S. Romas’ko, 2007, published in Koks i Khimiya, 2007, No. 3, pp. 20–23. COKE V. S. Romas’ko Kharkov State Technical University of Construction and Architecture, Ukraine DOI: 10.3103/S1068364X07030040 Discussions of coke-battery design in this journal damentally impossible to construct a calculation scheme have covered a wide range of topics associated with permitting estimation of the stress state of the heating simplified description of its geometric properties, wall’s refractory lining, since it does not withstand ten- thanks to the reduction of the three-dimensional struc- sile stress and compression of the lining by additional ture to a one-dimensional beam scheme. For example, forces to fully compensate the tensile stress from flex- in selecting the calculation scheme for the heating wall ure is impossible. of a coke furnace, the properties of the coal batch and The carrying capacity of the wall is determined on the the carrying capacity of the heating wall are taken into basis of the limiting value q of the transverse-load inten- account in simulating the load on the structure. lim sity q above which cracks appear in

Journal

Coke and ChemistrySpringer Journals

Published: Jul 3, 2007

References