Experimental Investigation on Performance of Waste Cement Sludge and Silica Fume-Incorporated Portland Cement Concrete

Experimental Investigation on Performance of Waste Cement Sludge and Silica Fume-Incorporated... An experimental investigation on improvisation of the conventional concrete mix by way of incorporating waste by products in view of facilitating partial substitution of concrete ingredients has been reported. The mechanical and durability properties of concrete mix incorporated with waste cement sludge and silica fume were test verified, and the optimal cement replacement proportion was identified. Based on test results, the technical feasibility and performance were assessed. The cement sludge content was partially replaced from 2 to 10% at an increment rate of 2% by weight of cement. The optimum cement sludge content has been identified as 4%. The optimal replacement percentage of silica fume along with 4% cement sludge was experimented up on. The silica fume content was varied from 3 to 12%, yielding dependable and optimal proportions of silica fume at 8% by weight of cement. Relationship between the 28-day compressive and flexural strength was established using an empirical correlation equation. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of The Institution of Engineers (India): Series A Springer Journals

Experimental Investigation on Performance of Waste Cement Sludge and Silica Fume-Incorporated Portland Cement Concrete

Loading next page...
 
/lp/springer-journals/experimental-investigation-on-performance-of-waste-cement-sludge-and-uT0OdxWb8H

References (35)

Publisher
Springer Journals
Copyright
Copyright © 2019 by The Institution of Engineers (India)
Subject
Engineering; Civil Engineering
ISSN
2250-2149
eISSN
2250-2157
DOI
10.1007/s40030-019-00399-3
Publisher site
See Article on Publisher Site

Abstract

An experimental investigation on improvisation of the conventional concrete mix by way of incorporating waste by products in view of facilitating partial substitution of concrete ingredients has been reported. The mechanical and durability properties of concrete mix incorporated with waste cement sludge and silica fume were test verified, and the optimal cement replacement proportion was identified. Based on test results, the technical feasibility and performance were assessed. The cement sludge content was partially replaced from 2 to 10% at an increment rate of 2% by weight of cement. The optimum cement sludge content has been identified as 4%. The optimal replacement percentage of silica fume along with 4% cement sludge was experimented up on. The silica fume content was varied from 3 to 12%, yielding dependable and optimal proportions of silica fume at 8% by weight of cement. Relationship between the 28-day compressive and flexural strength was established using an empirical correlation equation.