Core designing of a new type of TVS-2M FAs: neutronics and thermal-hydraulics design basis limits

Core designing of a new type of TVS-2M FAs: neutronics and thermal-hydraulics design basis limits One of the most important aims of this study is to improve the core of the current VVER reactors to achieve more burn-up (or more cycle length) and more intrinsic safety. It is an independent study on the Russian new proposed FAs, called TVS-2M, which would be applied for the future advanced VVERs. Some important aspects of neutronics as well as thermal hydraulics investigations (and analysis) of the new type of Fas are conducted, and results are compared with the standards PWR CDBL. The TVS-2M FA contains gadolinium-oxide which is mixed with UO2 (for different Gd densities and U-235 enrichments which are given herein), but the core does not contain BARs. The new type TVS-2M Fas are modeled by the SARCS software package to find the PMAXS format for three states of CZP and HZP as well as HFP, and then the whole core is simulated by the PARCS code to investigate transient conditions. In addition, the WIMS-D5 code is suggested for steady core modeling including TVS-2M FAs and/or TVS FAs. Many neutronics aspects such as the first cycle length (first cycle burn up in terms of MWthd/kgU), the critical concentration of boric acid at the BOC as well as the cycle length, the axial, and radial power peaking factors, differential and integral worthy of the most reactive CPS-CRs, reactivity coefficients of the fuel, moderator, boric acid, and the under-moderation estimation of the core are conducted and benchmarked with the PWR CDBL. Specifically, the burn-up calculations indicate that the 45.6 d increase of the first cycle length (which corresponds to 1.18 MWthd/kgU increase of burnup) is the best improving aim of the new FA type called TVS-2M. Moreover, thermal-hydraulics core design criteria such as MDNBR (based on W3 correlation) and the maximum of fuel and clad temperatures (radially and axially), are investigated, and discussed based on the CDBL. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png "Frontiers in Energy" Springer Journals

Core designing of a new type of TVS-2M FAs: neutronics and thermal-hydraulics design basis limits

"Frontiers in Energy" , Volume 15 (1) – Sep 26, 2018

Loading next page...
 
/lp/springer-journals/core-designing-of-a-new-type-of-tvs-2m-fas-neutronics-and-thermal-9LZ0iANXaj

References (22)

Publisher
Springer Journals
Copyright
Copyright © Higher Education Press 2018
ISSN
2095-1701
eISSN
2095-1698
DOI
10.1007/s11708-018-0583-x
Publisher site
See Article on Publisher Site

Abstract

One of the most important aims of this study is to improve the core of the current VVER reactors to achieve more burn-up (or more cycle length) and more intrinsic safety. It is an independent study on the Russian new proposed FAs, called TVS-2M, which would be applied for the future advanced VVERs. Some important aspects of neutronics as well as thermal hydraulics investigations (and analysis) of the new type of Fas are conducted, and results are compared with the standards PWR CDBL. The TVS-2M FA contains gadolinium-oxide which is mixed with UO2 (for different Gd densities and U-235 enrichments which are given herein), but the core does not contain BARs. The new type TVS-2M Fas are modeled by the SARCS software package to find the PMAXS format for three states of CZP and HZP as well as HFP, and then the whole core is simulated by the PARCS code to investigate transient conditions. In addition, the WIMS-D5 code is suggested for steady core modeling including TVS-2M FAs and/or TVS FAs. Many neutronics aspects such as the first cycle length (first cycle burn up in terms of MWthd/kgU), the critical concentration of boric acid at the BOC as well as the cycle length, the axial, and radial power peaking factors, differential and integral worthy of the most reactive CPS-CRs, reactivity coefficients of the fuel, moderator, boric acid, and the under-moderation estimation of the core are conducted and benchmarked with the PWR CDBL. Specifically, the burn-up calculations indicate that the 45.6 d increase of the first cycle length (which corresponds to 1.18 MWthd/kgU increase of burnup) is the best improving aim of the new FA type called TVS-2M. Moreover, thermal-hydraulics core design criteria such as MDNBR (based on W3 correlation) and the maximum of fuel and clad temperatures (radially and axially), are investigated, and discussed based on the CDBL.