J. Foo, S. Wilson (2006)
A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion statesMedical and Biological Engineering and Computing, 44
Liu Zheng-ping (2006)
The Detection of Weak Sinusoidal Signal Based on Multi-layer AutocorrelationLight Industry Machinery
(2004)
The effects of motion and low perfusion on the 308 accuracy of pulse oximetry
W Daxiang (2004)
333J Clin Anesthesiol, 20
Byung Kim, S. Yoo (2006)
Motion artifact reduction in photoplethysmography using independent component analysisIEEE Transactions on Biomedical Engineering, 53
Shuangping Tan, Zhiguang Ai, Yuxing Yang, Q. Xie (2013)
[Design of a pulse oximeter used to low perfusion and low oxygen saturation].Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation, 37 3
G. Lü (2005)
Study on Measuring Method of Human Oxygen SaturationChinese Journal of Medical Device
B. Docherty (2002)
Cardiorespiratory physical assessment for the acutely ill: 1.British journal of nursing, 11 11
R. Yousefi, M. Nourani, S. Ostadabbas, I. Panahi (2014)
A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic BiosensorsIEEE Journal of Biomedical and Health Informatics, 18
Huang Xiao-hong (2007)
An Inspecting Technology for Weak Sinusoidal Signal Based on Multi-layer AutocorrelationJournal of Chinese Computer Systems
F Xiaozhi (2007)
566J Chin Comput Syst, 28
SP Tan, ZG Ai, YX Yang, QG Xie (2013)
Design of a pulse oximeter used to low perfusion and low oxygen saturationChin J Med Instrum, 37
(2008)
System and methods for determing blood oxygen saturation values using complex number encoding
H. Sharma (2019)
Heart rate extraction from PPG signals using variational mode decompositionBiocybernetics and Biomedical Engineering
Y Xinzhong, Y Jing, G Lue (2005)
Study on measuring method of human oxygen saturationMedical Equipment, 12
Y Xinzhong (2005)
1Medical Equipment, 12
K Zhang (2009)
586Chinese Journal of Scientific Instrument, 30
G. Biagetti, P. Crippa, L. Falaschetti, S. Orcioni, C. Turchetti (2019)
Reduced complexity algorithm for heart rate monitoring from PPG signals using automatic activity intensity classifierBiomed. Signal Process. Control., 52
C Mingkui (2006)
112Light Ind Mach, 24
Bin Sun, Chengchao Wang, Chen Xiaohui, Zhang Yongfang, Hanyu Shao (2019)
PPG signal motion artifacts correction algorithm based on feature estimationOptik
Choon-Hian Goh, L. Tan, N. Lovell, S. Ng, T. Pin, E. Lim (2020)
Robust PPG motion artifact detection using a 1-D convolution neural networkComputer methods and programs in biomedicine, 196
Yu-tong Zha, Guang-Da Liu, Shan Xiaohu, F. Wang, Jing Cai, Xing Wei (2018)
Non-invasive assessment of cerebral hemodynamics with CWNIRS-ICG and application of EEMD-SSE in PPG signal extractionOptik, 156
Yong-Sheng Yan, Yuan-ting Zhang (2008)
An Efficient Motion-Resistant Method for Wearable Pulse OximeterIEEE Transactions on Information Technology in Biomedicine, 12
L Guangda (2009)
169LASER & INFRARED, 39
K Zhang, T Jiao, F Fu, W Zhang, X Dong (2009)
Motion artifact cancellation in photoplethysmography using reconstruction of wavelet transform modulus maximaChinese Journal of Scientific Instrument, 30
Jake Campbell, C. Pretty, J. Chase, P. Bones (2018)
Near-Real-Time Detection of Pulse Oximeter PPG Peaks Using Wavelet DecompositionIFAC-PapersOnLine, 51
SP Tan (2013)
189Chin J Med Instrum, 37
Bai Ming-ming (2009)
Blood Oxygen Saturation Measurement Based on Volume Signal AnalysisLaser & Infrared
BackgroundSpO2 is a widely used estimation of oxygen saturation owing to its convenient usage and low cost. However, SpO2 determination under low perfusion condition is severely affected by noise.MethodsIn this paper, an autocorrelation modeling method for the oxygen saturation measurement during low perfusion is presented. The proposed method mainly contains two steps: calculating the autocorrelation of the photoplethysmography (PPG) signals and modeling for the parameter calculation. The autocorrelation of the PPG signals can suppress the noise and extract pulse waves from low perfusion signals. The model can realize the calculation of SpO2 with the autocorrelation signals.ResultsExperiments showed that the new method had a good accuracy and stability under low perfusion condition (perfusion index (PI) ≤ 0.2%), and it was also motion-tolerant. Meanwhile, the new method showed a good performance for the oxygen saturation measurement under the condition of lower perfusion (PI = 0.1%).ConclusionsThe new method could realize the calculation of SpO2 by little computation and high efficiency without extra hardware. It has strong potential in real-time clinical use.
Research on Biomedical Engineering – Springer Journals
Published: Dec 1, 2022
Keywords: PPG; SpO2 extraction; Low perfusion; Autocorrelation modeling method
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.