A new performance evaluation method and its application in fin-tube surface design of small diameter tube

A new performance evaluation method and its application in fin-tube surface design of small... Abstract In this paper, a simple yet efficient performance comparison method is proposed based on the assumptions of constant properties and identical frontal area. For this method, no correlations are required, and a small number of discrete data are sufficient. To illustrate the feasibility of the proposed approach, a new slotted fin with 4 mm tubes is designed to replace the original louvered fin with tubes of 7 mm. The orthogonal design method is adopted in the fin design to reduce the number of computational cases significantly, and yet a nearly optimum combination of major geometric factors can still be obtained. The reasonable parametric combination of 3 global parameters is obtained by analyzing the numerical results of 16 plain plate fins. Based on this result, 3 new slotted fins with different fin pitches are studied. The slotted fin with a fin pitch of 1.4 mm is recommended after considering the heat transfer, comprehensive performance, and cost of material and operation. The result shows that compared with the original louvered fin, the recommended fin not only increases the heat transfer rate by 2.2%, 22.5%, and 13.7% under an identical flow rate, identical pressure drop, and identical pumping power constraint, respectively, but also saves approximately 36% of the copper tube materials. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png "Frontiers in Energy" Springer Journals

A new performance evaluation method and its application in fin-tube surface design of small diameter tube

Loading next page...
 
/lp/springer-journals/a-new-performance-evaluation-method-and-its-application-in-fin-tube-80fGRmLWgr
Publisher
Springer Journals
Copyright
2010 Higher Education Press and Springer-Verlag Berlin Heidelberg
ISSN
2095-1701
eISSN
1673-7504
DOI
10.1007/s11708-010-0132-8
Publisher site
See Article on Publisher Site

Abstract

Abstract In this paper, a simple yet efficient performance comparison method is proposed based on the assumptions of constant properties and identical frontal area. For this method, no correlations are required, and a small number of discrete data are sufficient. To illustrate the feasibility of the proposed approach, a new slotted fin with 4 mm tubes is designed to replace the original louvered fin with tubes of 7 mm. The orthogonal design method is adopted in the fin design to reduce the number of computational cases significantly, and yet a nearly optimum combination of major geometric factors can still be obtained. The reasonable parametric combination of 3 global parameters is obtained by analyzing the numerical results of 16 plain plate fins. Based on this result, 3 new slotted fins with different fin pitches are studied. The slotted fin with a fin pitch of 1.4 mm is recommended after considering the heat transfer, comprehensive performance, and cost of material and operation. The result shows that compared with the original louvered fin, the recommended fin not only increases the heat transfer rate by 2.2%, 22.5%, and 13.7% under an identical flow rate, identical pressure drop, and identical pumping power constraint, respectively, but also saves approximately 36% of the copper tube materials.

Journal

"Frontiers in Energy"Springer Journals

Published: Mar 1, 2011

References