Access the full text.
Sign up today, get DeepDyve free for 14 days.
P. Lewis, D. Alexander (1990)
HTB2: A flexible model for dynamic building simulationBuilding and Environment, 25
Siddharth Goyal, P. Barooah (2012)
A method for model-reduction of non-linear thermal dynamics of multi-zone buildingsEnergy and Buildings, 47
(1991)
Nonlinear dynamics and control for thermal room models
Himanshu Dehra (2009)
A two dimensional thermal network model for a photovoltaic solar wallSolar Energy, 83
T. Matsuba, K. Kamimura, M. Kasahara, Akiomi Kimbara, S. Kurosu, I. Murasawa, Y. Hashimoto (1998)
Stability limit of room air temperature of a VAV system
Y Kuzuu M Kasahara (2000)
Physical model of an airconditioned space for control analysisASHRAE Transactions, 106
H F Sullivan A K Athienitis (1986)
Analytical model, sensitivity analysis, and algorithm for temperature swings in direct gain roomsScience Energy, 36
A. Athienitis, H. Sullivan, K. Hollands (1986)
Analytical model, sensitivity analysis, and algorithm for temperature swings in direct gain roomsSolar Energy, 36
P. Riederer, D. Marchio, J. Visier, A. Husaunndee, R. Lahrech (2002)
Room thermal modelling adapted to the test of HVAC control systemsBuilding and Environment, 37
G. Singh, M. Zaheer-Uddin, Rajni Patel (2000)
Adaptive control of multivariable thermal processes in HVAC systemsEnergy Conversion and Management, 41
L. Glicksman, S. Taub (1997)
Thermal and behavioral modeling of occupant-controlled heating, ventilating and air conditioning systemsEnergy and Buildings, 25
C. Ruivo, P. Ferreira, D. Vaz (2013)
Prediction of thermal load temperature difference values for the external envelope of rooms with setback and setup thermostatsApplied Thermal Engineering, 51
B. Børresen (1981)
Thermal room models for control analysisAshrae Transactions, 87
(1999)
Dynamic performance of an electronics zone air temperature control loop in a typical variableair-volume air conditioning system
J. Braun, Kent Montgomery, N. Chaturvedi (2001)
Evaluating the Performance of Building Thermal Mass Control StrategiesHVAC&R Research, 7
Abstract The zone model has been widely applied in control analysis of heating, ventilation and air conditioning (HVAC) systems to achieve a high building efficiency. This paper proposed a modified zone model which is much simpler in the HVAC system simulation and has the similar accuracy to the complicated simulation model. The proposed model took into consideration the effect of envelop heat reservoir on the room indoor temperature by introducing the thermal admittance of the inner surfaces of the building enclosure. The thermal admittance for the building enclosure was developed based on the building thermal network analytical theory and transfer function method. The efficacy of the proposed model was demonstrated by comparing it with the complicated model — heat balance method (HTB2 program). The predicted results from the proposed model well agreed with those from the complicated simulation. The proposed model can then make the HVAC system dynamic simulation much faster and more acceptable for control design due to its simplicity and efficiency.
"Frontiers in Energy" – Springer Journals
Published: Sep 1, 2013
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.