Consistency of visual assessments of mammographic breast density from vendor-specific “for presentation” images

Consistency of visual assessments of mammographic breast density from vendor-specific “for... Abstract. Discussions of percent breast density (PD) and breast cancer risk implicitly assume that visual assessments of PD are comparable between vendors despite differences in technology and display algorithms. This study examines the extent to which visual assessments of PD differ between mammograms acquired from two vendors. Pairs of “for presentation” digital mammography images were obtained from two mammography units for 146 women who had a screening mammogram on one vendor unit followed by a diagnostic mammogram on a different vendor unit. Four radiologists independently visually assessed PD from single left mediolateral oblique view images from the two vendors. Analysis of variance, intra-class correlation coefficients (ICC), scatter plots, and Bland–Altman plots were used to evaluate PD assessments between vendors. The mean radiologist PD for each image was used as a consensus PD measure. Overall agreement of the PD assessments was excellent between the two vendors with an ICC of 0.95 (95% confidence interval: 0.93 to 0.97). Bland–Altman plots demonstrated narrow upper and lower limits of agreement between the vendors with only a small bias (2.3 percentage points). The results of this study support the assumption that visual assessment of PD is consistent across mammography vendors despite vendor-specific appearances of “for presentation” images. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Medical Imaging SPIE

Consistency of visual assessments of mammographic breast density from vendor-specific “for presentation” images

Consistency of visual assessments of mammographic breast density from vendor-specific “for presentation” images


Discussions of percent breast density (PD) and breast cancer risk implicitly assume that visual assessments of PD are comparable between vendors despite differences in technology and display algorithms. This study examines the extent to which visual assessments of PD differ between mammograms acquired from two vendors. Pairs of "for presentation" digital mammography images were obtained from two mammography units for 146 women who had a screening mammogram on one vendor unit followed by a diagnostic mammogram on a different vendor unit. Four radiologists independently visually assessed PD from single left mediolateral oblique view images from the two vendors. Analysis of variance, intra-class correlation coefficients (ICC), scatter plots, and Bland­Altman plots were used to evaluate PD assessments between vendors. The mean radiologist PD for each image was used as a consensus PD measure. Overall agreement of the PD assessments was excellent between the two vendors with an ICC of 0.95 (95% confidence interval: 0.93 to 0.97). Bland­Altman plots demonstrated narrow upper and lower limits of agreement between the vendors with only a small bias (2.3 percentage points). The results of this study support the assumption that visual assessment of PD is consistent across mammography vendors despite vendor-specific appearances of "for presentation" images. © The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. [DOI: 10.1117/1.JMI.3.1.011004] Keywords: digital mammography; mammographic density; agreement; reader variability. Paper 15147SSRR received Jul. 15, 2015; accepted for publication Sep. 23, 2015; published online Oct. 30, 2015. Introduction Percent mammographic breast density (PD) determined from "for presentation" mammography images is a well-known risk...
Loading next page...
 
/lp/spie/consistency-of-visual-assessments-of-mammographic-breast-density-from-uaW8T8vM7D
Publisher
SPIE
Copyright
© The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Subject
Special Section on Medical Image Perception and Observer Performance; Paper
ISSN
2329-4302
eISSN
2329-4310
DOI
10.1117/1.JMI.3.1.011004
pmid
26870747
Publisher site
See Article on Publisher Site

Abstract

Abstract. Discussions of percent breast density (PD) and breast cancer risk implicitly assume that visual assessments of PD are comparable between vendors despite differences in technology and display algorithms. This study examines the extent to which visual assessments of PD differ between mammograms acquired from two vendors. Pairs of “for presentation” digital mammography images were obtained from two mammography units for 146 women who had a screening mammogram on one vendor unit followed by a diagnostic mammogram on a different vendor unit. Four radiologists independently visually assessed PD from single left mediolateral oblique view images from the two vendors. Analysis of variance, intra-class correlation coefficients (ICC), scatter plots, and Bland–Altman plots were used to evaluate PD assessments between vendors. The mean radiologist PD for each image was used as a consensus PD measure. Overall agreement of the PD assessments was excellent between the two vendors with an ICC of 0.95 (95% confidence interval: 0.93 to 0.97). Bland–Altman plots demonstrated narrow upper and lower limits of agreement between the vendors with only a small bias (2.3 percentage points). The results of this study support the assumption that visual assessment of PD is consistent across mammography vendors despite vendor-specific appearances of “for presentation” images.

Journal

Journal of Medical ImagingSPIE

Published: Jan 1, 2016

There are no references for this article.