The Automated, Accurate and Reproducible Determination of Steady-state Permeation Parameters from Percutaneous Permeation Data

The Automated, Accurate and Reproducible Determination of Steady-state Permeation Parameters from... Procedures for the in vitro determination of percutaneous permeation with Franz diffusion cells are widely accepted. However, the calculation of relevant endpoints, such as the steady-state flux (J) and the permeation coefficient (Papp), still depends on visual data inspection or an approximation of the steady-state flux as the maximum observed absorption rate. As both these approaches must be considered inappropriate, an automated and reproducible algorithm to analyse permeation data is presented. The method detects both lag-times and non-linear data resulting from substance accumulation in the acceptor compartment of static diffusion cells. It was evaluated by using simulated data, and data from experiments with caffeine and testosterone on bovine udder skin and human reconstituted epidermis (SkinEthic®), which represent model barriers with high and low barrier strengths, respectively. It was shown that the algorithm is a suitable method for the identification of steady-state ranges in permeation data. If used on data generated with appropriate experimental approaches, it is a reproducible and time-saving alternative to the visual analysis of diffusion data. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Alternatives to Laboratory Animals SAGE

The Automated, Accurate and Reproducible Determination of Steady-state Permeation Parameters from Percutaneous Permeation Data

Loading next page...
 
/lp/sage/the-automated-accurate-and-reproducible-determination-of-steady-state-C8p0Xyp7mC

References (16)

Publisher
SAGE
Copyright
© 2008 Fund for the Replacement of Animals in Medical Experiments
ISSN
0261-1929
eISSN
2632-3559
DOI
10.1177/026119290803600209
Publisher site
See Article on Publisher Site

Abstract

Procedures for the in vitro determination of percutaneous permeation with Franz diffusion cells are widely accepted. However, the calculation of relevant endpoints, such as the steady-state flux (J) and the permeation coefficient (Papp), still depends on visual data inspection or an approximation of the steady-state flux as the maximum observed absorption rate. As both these approaches must be considered inappropriate, an automated and reproducible algorithm to analyse permeation data is presented. The method detects both lag-times and non-linear data resulting from substance accumulation in the acceptor compartment of static diffusion cells. It was evaluated by using simulated data, and data from experiments with caffeine and testosterone on bovine udder skin and human reconstituted epidermis (SkinEthic®), which represent model barriers with high and low barrier strengths, respectively. It was shown that the algorithm is a suitable method for the identification of steady-state ranges in permeation data. If used on data generated with appropriate experimental approaches, it is a reproducible and time-saving alternative to the visual analysis of diffusion data.