Access the full text.
Sign up today, get DeepDyve free for 14 days.
Akhtar Gul, B. Alam, F. Khan, Y. Badrashi, K. Shahzada (2015)
Strengthening and Evaluation of Reinforced Concrete Beams for Flexure by Using External Steel ReinforcementsInternational Journal of Scientific Engineering and Technology, 4
U. Ebead, K. Shrestha, M. Afzal, A. Refai, A. Nanni (2016)
Effectiveness of Fabric-Reinforced Cementitious Matrix in Strengthening Reinforced Concrete BeamsJournal of Composites for Construction, 21
B. Bahn, R. Harichandran (2008)
Flexural Behavior of Reinforced Concrete Beams Strengthened with CFRP Sheets and Epoxy MortarJournal of Composites for Construction, 12
C. Cazacu, T. Galatanu, P. Mizgan, R. Muntean, F. Tamas (2017)
Experimental Research in Flexural Behavior of Carbon Fiber Polymer Strengthened BeamsProcedia Engineering, 181
Xu Yang, W. Gao, J. Dai, Zhou-dao Lu, Kequan Yu (2018)
Flexural strengthening of RC beams with CFRP grid-reinforced ECC matrixComposite Structures, 189
Z. Aljazaeri, J. Myers (2017)
Fatigue and Flexural Behavior of Reinforced-Concrete Beams Strengthened with Fiber-Reinforced Cementitious MatrixJournal of Composites for Construction, 21
I. Qeshta, P. Shafigh, M. Jumaat (2015)
Flexural behaviour of RC beams strengthened with wire mesh-epoxy compositeConstruction and Building Materials, 79
(2012)
Standard specification for Portland cement
Pu Zhang, Hong Zhu, Gang Wu, Meng Shaoping, Zhishen Wu (2017)
Flexural Performance of HFRP-RC Composite T-Beams with Different InterfacesJournal of Composites for Construction, 21
Kang-Su Kim, D. Lee, Sung-Mo Choi, Y. Choi, Suengwoon Jung (2011)
Flexural behavior of prestressed composite beams with corrugated web: Part I. Development and analysisComposites Part B-engineering, 42
J. Gonzalez-Libreros, L. Sneed, Tommaso D’Antino, Carlo Pellegrino (2017)
Behavior of RC beams strengthened in shear with FRP and FRCM compositesEngineering Structures, 150
(2003)
Standard specification for concrete aggregates
(2019)
318-19 Building Code Requirements for Structural Concrete and Commentary
Wensu Chen, T. Pham, H. Sichembe, Li Chen, H. Hao (2018)
Experimental study of flexural behaviour of RC beams strengthened by longitudinal and U-shaped basalt FRP sheetComposites Part B-engineering, 134
Cheng Chen, L. Cheng (2017)
Predicting Flexural Fatigue Performance of RC Beams Strengthened with Externally Bonded FRP due to FRP DebondingJournal of Bridge Engineering, 22
H. Rasheed, Jamal Abdalla, R. Hawileh, A. Al-Tamimi (2017)
Flexural behavior of reinforced concrete beams strengthened with externally bonded Aluminum Alloy platesEngineering Structures, 147
(2015)
Standard test method for compressive strength of cylindrical concrete specimens
A. D’Ambrisi, F. Focacci (2011)
Flexural Strengthening of RC Beams with Cement-Based CompositesJournal of Composites for Construction, 15
L. Sneed, S. Verre, C. Carloni, L. Ombres (2016)
Flexural behavior of RC beams strengthened with steel-FRCM compositeEngineering Structures, 127
S. Chiew, Qin Sun, Yi Yu (2007)
Flexural Strength of RC Beams with GFRP LaminatesJournal of Composites for Construction, 11
P. Holtzmann (2016)
Steel Construction Manual
G. Campione, L. Cavaleri, M. Papia (2015)
Flexural response of external R.C. beam-column joints externally strengthened with steel cagesEngineering Structures, 104
(2007)
Standard practice for making and curing concrete test specimens in the laboratory. Figure 11. Faliure of control specimen
Strengthening of structural members is a common practice around the world that may arise due to deterioration of concrete with age or upgradation of design code. This paper aims to elucidate a technique used for strengthening of the reinforced concrete beam for flexural capacity by using externally welded steel angles and steel bars. For this motive, three beams were strengthened with external steel angles and three with external steel bars. The external strengthening steel elements were attached at the bottom of the beam with shear reinforcement. Control samples without external steel angles and steel bars for comparison purposes were also prepared. All reinforced concrete beams were first constructed using a concrete ratio of 1:2:4, and then external steel elements were added to existing flexural reinforcement by using a fillet weld with tee joints having thickness and length of 5/16" (7.9 mm) and 6" (152.4 mm), respectively. Fourth point loading criteria were used to investigate the flexural capacity of beams in positive bending. All beams were designed strong enough in shear, to resist the ultimate loads without shear failure. Test results indicated that beams strengthened with this technique have an average increase of 238% with steel angles and 106% with steel bars, in load-carrying capacity than control samples. Strengthened beams showed a uniform crack pattern. Moreover, the concrete cover made a good bond with existing concrete and was strong enough to withstand ultimate loads. Conclusively, the steel angles and steel bars can be used as an external strengthening material, to enhance the flexural capacity of reinforced concrete beams.
Advances in Structural Engineering – SAGE
Published: Jan 1, 2021
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.