RETRACTED: Transient stability improvement analysis in a grid-connected doubly fed induction generator–based wind generator

RETRACTED: Transient stability improvement analysis in a grid-connected doubly fed induction... In this article, transient stability enhancement analysis of the doubly fed induction generator–based variable speed wind generator is performed among the most promising series compensating devices like the diode-bridge-type non-superconductor fault current limiter, bridge-type fault current limiter, series dynamic braking resistor, resistive solid-state fault current limiter, and DC resistive superconducting fault current limiter. Although all series technologies are well documented in literatures, so far no comparison among them is reported. Therefore, to fill this gap, this article provides a detailed analytical analysis, and comparison is done the among the series compensators in terms of transient stability performances, implementation feasibility, control structure, and cost. A temporary balanced and unbalanced fault was applied in the doubly fed induction generator–based test system model to demonstrate the transient stability performance among the series compensating devices. In this work, extensive simulations were executed in MATLAB/Simulink software, and the simulation result shows that the mentioned series devices can augment the transient stability during the fault; however, the non-superconductor fault current limiter and the DC resistive superconducting fault current limiter are the most effective series devices and performed well in comparison to others. Thus, this comparison study provides a guideline to select an appropriate transient stability http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Wind Engineering SAGE

RETRACTED: Transient stability improvement analysis in a grid-connected doubly fed induction generator–based wind generator

Wind Engineering , Volume OnlineFirst: 1 – Mar 1, 2018

Loading next page...
 
/lp/sage/retracted-transient-stability-improvement-analysis-in-a-grid-connected-GqvmQ0psHN

References (35)

Publisher
SAGE
Copyright
© The Author(s) 2017
ISSN
0309-524X
eISSN
2048-402X
DOI
10.1177/0309524X17709925
Publisher site
See Article on Publisher Site

Abstract

In this article, transient stability enhancement analysis of the doubly fed induction generator–based variable speed wind generator is performed among the most promising series compensating devices like the diode-bridge-type non-superconductor fault current limiter, bridge-type fault current limiter, series dynamic braking resistor, resistive solid-state fault current limiter, and DC resistive superconducting fault current limiter. Although all series technologies are well documented in literatures, so far no comparison among them is reported. Therefore, to fill this gap, this article provides a detailed analytical analysis, and comparison is done the among the series compensators in terms of transient stability performances, implementation feasibility, control structure, and cost. A temporary balanced and unbalanced fault was applied in the doubly fed induction generator–based test system model to demonstrate the transient stability performance among the series compensating devices. In this work, extensive simulations were executed in MATLAB/Simulink software, and the simulation result shows that the mentioned series devices can augment the transient stability during the fault; however, the non-superconductor fault current limiter and the DC resistive superconducting fault current limiter are the most effective series devices and performed well in comparison to others. Thus, this comparison study provides a guideline to select an appropriate transient stability