Calculation Method of shear strength of vertical stiffener connections to L-CFST columns

Calculation Method of shear strength of vertical stiffener connections to L-CFST columns Based on the low cyclic loading test results of vertical stiffener connections between L-shaped columns composed of concrete-filled steel tubes and steel beams, a simplified trilinear model to predict the shear strength versus the shear deformation response in panel zone is presented in this article. Considering the characteristics of the panel zone, the strength of the joints is determined by contributions from the web of steel tubes and internal short beams, core concrete diagonal struts and the steel frame yield hinge mechanism. Existing calculation methods, which are applicable to the vertical stiffener connection to L-shaped columns composed of concrete-filled steel tube, are summarized and modified in this article. In addition, the use of the proposed design equations led to excellent agreement with experimental shear strength for both corner and exterior vertical stiffener connections to L-shaped columns composed of concrete-filled steel tube. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Advances in Structural Engineering SAGE

Calculation Method of shear strength of vertical stiffener connections to L-CFST columns

Loading next page...
 
/lp/sage/calculation-method-of-shear-strength-of-vertical-stiffener-connections-dGnYF5O0mV

References (12)

Publisher
SAGE
Copyright
© The Author(s) 2017
ISSN
1369-4332
eISSN
2048-4011
DOI
10.1177/1369433217732496
Publisher site
See Article on Publisher Site

Abstract

Based on the low cyclic loading test results of vertical stiffener connections between L-shaped columns composed of concrete-filled steel tubes and steel beams, a simplified trilinear model to predict the shear strength versus the shear deformation response in panel zone is presented in this article. Considering the characteristics of the panel zone, the strength of the joints is determined by contributions from the web of steel tubes and internal short beams, core concrete diagonal struts and the steel frame yield hinge mechanism. Existing calculation methods, which are applicable to the vertical stiffener connection to L-shaped columns composed of concrete-filled steel tube, are summarized and modified in this article. In addition, the use of the proposed design equations led to excellent agreement with experimental shear strength for both corner and exterior vertical stiffener connections to L-shaped columns composed of concrete-filled steel tube.

Journal

Advances in Structural EngineeringSAGE

Published: Apr 1, 2018

There are no references for this article.