K. Otto (2007)
Volumetric modulated arc therapy: IMRT in a single gantry arc.Medical physics, 35 1
O. Algan, A. Jamgade, I. Ali, A. Christie, J. Thompson, D. Thompson, Salahuddin Ahmad, T. Herman (2012)
The dosimetric impact of daily setup error on target volumes and surrounding normal tissue in the treatment of prostate cancer with intensity-modulated radiation therapy.Medical dosimetry : official journal of the American Association of Medical Dosimetrists, 37 4
M. Teoh, C. Clark, K. Wood, S. Whitaker, A. Nisbet (2011)
Volumetric modulated arc therapy: a review of current literature and clinical use in practice.The British journal of radiology, 84 1007
C. Garibaldi, C. Fodor, G. Riva, D. Rojas, S. Dicuonzo, E. Pace, G. Fanetti, P. Marco, V. Dell’Acqua, G. Marvaso, M. Leonardi, R. Lazzari, F. Cattani, M. Cremonesi, R. Orecchia, B. Jereczek-Fossa (2018)
Cone-beam CT-based inter-fraction localization errors for tumors in the pelvic region.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics, 46
C. Franzese, A. Fogliata, M. Loi, M. Badalamenti, D. Franceschini, T. Comito, L. Cozzi, G. Reggiori, S. Tomatis, M. Scorsetti (2021)
Dosimetric impact of volumetric modulated arc therapy for nasopharyngeal cancer treatmentReports of Practical Oncology and Radiotherapy, 26
Y. Oh, J. Baek, O. Kim, Jinhee Kim (2014)
Assessment of setup uncertainties for various tumor sites when using daily CBCT for more than 2200 VMAT treatmentsJournal of Applied Clinical Medical Physics, 15
Kevin Bylund, J. Bayouth, Mark Smith, A. Hass, S. Bhatia, J. Buatti (2008)
Analysis of interfraction prostate motion using megavoltage cone beam computed tomography.International journal of radiation oncology, biology, physics, 72 3
D. Jaffray (2012)
Image-guided radiotherapy: from current concept to future perspectivesNature Reviews Clinical Oncology, 9
S. Murchison, K. DeVries, S. Atrchian (2020)
Patient Outcomes With Dose Escalation Using Modern Radiotherapy Techniques: A Retrospective Review of Anal Cancer Treated at a Large Academic Institution Between 2010 and 2016Cureus, 12
S. Webb (2002)
Intensity-modulated radiation therapy using only jaws and a mask: II. A simplified concept of relocatable single-bixel attenuatorsPhysics in Medicine & Biology, 47
Heng Li, X. Zhu, L. Zhang, L. Dong, S. Tung, A. Ahamad, K. Chao, W. Morrison, D. Rosenthal, D. Schwartz, R. Mohan, A. Garden (2008)
Comparison of 2D radiographic images and 3D cone beam computed tomography for positioning head-and-neck radiotherapy patients.International journal of radiation oncology, biology, physics, 71 3
Reports of Practical Oncology and Radiotherapy The importance of image guided radiotherapy in small cell lung cancer: Case report and review of literature
W. Zou, L. Dong, Boon-Keng Teo (2018)
Current State of Image Guidance in Radiation Oncology: Implications for PTV Margin Expansion and Adaptive Therapy.Seminars in radiation oncology, 28 3
D. Simpson, Joshua Lawson, S. Nath, B. Rose, A. Mundt, L. Mell (2010)
A survey of image‐guided radiation therapy use in the United StatesCancer, 116
P. Kupelian, Choonik Lee, K. Langen, O. Zeidan, R. Manon, T. Willoughby, S. Meeks (2008)
Evaluation of image-guidance strategies in the treatment of localized prostate cancer.International journal of radiation oncology, biology, physics, 70 4
J. Santos, R. Popple, N. Agazaryan, J. Bayouth, J. Bissonnette, M. Bucci, S. Dieterich, L. Dong, K. Forster, D. Indelicato, K. Langen, J. Lehmann, N. Mayr, I. Parsai, William Salter, M. Tomblyn, W. Yuh, I. Chetty (2013)
Image guided radiation therapy (IGRT) technologies for radiation therapy localization and delivery.International journal of radiation oncology, biology, physics, 87 1
V. Rudat, Mohamed Hammoud, Y. Pillay, Abdul Alaradi, Adel Mohamed, S. Altuwaijri (2011)
Impact of the frequency of online verifications on the patient set-up accuracy and set-up marginsRadiation Oncology (London, England), 6
Murchison (2020)
e10989Cureus., 12
Joshua Lawson, E. Elder, T. Fox, Lawrence Davis, I. Crocker (2007)
Quantification of dosimetric impact of implementation of on-board imaging (OBI) for IMRT treatment of head-and-neck malignancies.Medical dosimetry : official journal of the American Association of Medical Dosimetrists, 32 4
R. Den, A. Doemer, G. Kubicek, G. Bednarz, J. Galvin, W. Keane, Ying Xiao, M. Machtay (2010)
Daily image guidance with cone-beam computed tomography for head-and-neck cancer intensity-modulated radiotherapy: a prospective study.International journal of radiation oncology, biology, physics, 76 5
T. Kataria, A. Abhishek, P. Chadha, Janardhan Nandigam (2011)
Set-up uncertainties: online correction with X-ray volume imaging.Journal of cancer research and therapeutics, 7 1
Kazi Afrin, Salahuddin Ahmad (2021)
Is IMRT or VMAT superior or inferior to 3D conformal therapy in the treatment of lung cancer? A brief literature reviewJournal of Radiotherapy in Practice, 21
L. Colbert, S. Moningi, A. Chadha, A. Amer, Yeonju Lee, R. Wolff, G. Varadhachary, J. Fleming, M. Katz, P. Das, S. Krishnan, E. Koay, P. Park, C. Crane, C. Taniguchi (2017)
Dose escalation with an IMRT technique in 15 to 28 fractions is better tolerated than standard doses of 3DCRT for LAPCAdvances in Radiation Oncology, 2
D. Delishaj, S. Ursino, F. Pasqualetti, F. Matteucci, A. Cristaudo, C. Soatti, A. Barcellini, F. Paiar (2018)
Set-up errors in head and neck cancer treated with IMRT technique assessed by cone-beam computed tomography: a feasible protocolRadiation Oncology Journal, 36
D. Jaffray, J. Siewerdsen, J. Wong, Alvaro Martinez (2002)
Flat-panel cone-beam computed tomography for image-guided radiation therapy.International journal of radiation oncology, biology, physics, 53 5
T. Bortfeld (2006)
IMRT: a review and previewPhysics in Medicine & Biology, 51
E. Mayyas, I. Chetty, M. Chetvertkov, N. Wen, T. Neicu, T. Nurushev, L. Ren, Mei Lu, H. Stricker, D. Pradhan, B. Movsas, M. Elshaikh (2013)
Evaluation of multiple image-based modalities for image-guided radiation therapy (IGRT) of prostate carcinoma: a prospective study.Medical physics, 40 4
K. Chao, J. Deasy, J. Markman, Joyce Haynie, C. Perez, J. Purdy, D. Low (2001)
A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: initial results.International journal of radiation oncology, biology, physics, 49 4
A. Yeung, Jonathan Li, W. Shi, Heather Newlin, A. Chvetsov, Chihray Liu, J. Palta, K. Olivier (2009)
Tumor localization using cone-beam CT reduces setup margins in conventionally fractionated radiotherapy for lung tumors.International journal of radiation oncology, biology, physics, 74 4
P. Rosenschold, M. Zelefsky, A. Apte, A. Jackson, J. Oh, Elliot Shulman, N. Desai, Margie Hunt, P. Ghadjar, E. Yorke, J. Deasy (2018)
Image-guided radiotherapy reduces the risk of under-dosing high-risk prostate cancer extra-capsular disease and improves biochemical controlRadiation Oncology (London, England), 13
C. Franzese, A. Fogliata, E. Clerici, D. Franceschini, E. Villa, G. D'agostino, P. Navarria, P. Mancosu, S. Tomatis, L. Cozzi, M. Scorsetti (2015)
Toxicity profile and early clinical outcome for advanced head and neck cancer patients treated with simultaneous integrated boost and volumetric modulated arc therapyRadiation Oncology (London, England), 10
M. Guckenberger, Juergen Meyer, D. Vordermark, K. Baier, J. Wilbert, M. Flentje (2006)
Magnitude and clinical relevance of translational and rotational patient setup errors: a cone-beam CT study.International journal of radiation oncology, biology, physics, 65 3
M. Herk (2004)
Errors and margins in radiotherapy.Seminars in Radiation Oncology, 14
Audrey Dang, P. Kupelian, M. Cao, N. Agazaryan, A. Kishan (2018)
Image-guided radiotherapy for prostate cancerTranslational Andrology and Urology, 7
Heming Lu, Hui Lin, Guosheng Feng, Jia-xin Chen, L. Shu, Q. Pang, Jinjian Cheng, Luxing Peng, Danling Wu, C. Liao, Y. Mo (2012)
Interfractional and intrafractional errors assessed by daily cone-beam computed tomography in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy: a prospective studyJournal of Radiation Research, 53
P. Kupelian, V. Thakkar, D. Khuntia, C. Reddy, E. Klein, A. Mahadevan (2005)
Hypofractionated intensity-modulated radiotherapy (70 gy at 2.5 Gy per fraction) for localized prostate cancer: long-term outcomes.International journal of radiation oncology, biology, physics, 63 5
Jean-Pierre Bissonnette, Peter Balter, L. Dong, Katja Langen, D. Lovelock, M. Miften, Douglas Moseley, J. Pouliot, J. Sonke, Sua Yoo (2012)
Quality assurance for image-guided radiation therapy utilizing CT-based technologies: a report of the AAPM TG-179.Medical physics, 39 4
Macarena Mesías, J. Boda-Heggemann, Johannes Thoelking, F. Lohr, F. Wenz, H. Wertz (2016)
Quantification and Assessment of Interfraction Setup Errors Based on Cone Beam CT and Determination of Safety Margins for RadiotherapyPLoS ONE, 11
L. Zhang, A. Garden, Justin Lo, K. Ang, A. Ahamad, W. Morrison, D. Rosenthal, Mark Chambers, X. Zhu, R. Mohan, L. Dong (2006)
Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy.International journal of radiation oncology, biology, physics, 64 5
This study aimed to evaluate the 6D inter-fraction tumour localisation errors in 20 tongue and 20 prostate cancer patients treated with intensity-modulated radiation therapy and volumetric-modulated arc therapy. The patient tumour localisation errors in lateral, longitudinal and vertical translation axes and pitch, roll and yaw rotational axes were analysed by automatic image registration of daily pretreatment kilovoltage cone-beam computed tomography (kV-CBCT) with planning CT in 1000 fractions. The overall mean error (M), systematic error (Σ), random error (σ) and planning target volume (PTV) margins were evaluated. The frequency distributions of setup errors were normally distributed about the mean except for pitch in the tongue and prostate. The overall 3D vector length ≥ 5 mm was 14.2 and 49.8% in the ca-tongue and ca-prostate, respectively. The frequency of rotational errors ≥1 degree was a maximum of 37 and 59.5%, respectively, in ca-tongue and ca-prostate. The M, Σ and σ for all translational and rotational axes decreased with increasing frequency of verification correction in ca-tongue and ca-prostate patients. Similarly, the PTV margin was reduced with no correction to alternate day correction from a maximum of 4.7 to 2.5 mm in ca-tongue and from a maximum of 8.6 to 4.7 mm in ca-prostate. The results emphasised the vital role of the higher frequency of kV-CBCT based setup correction in reducing M, Σ, σ and PTV margins in ca-tongue and ca-prostate patients.
Radiation Protection Dosimetry – Oxford University Press
Published: Jul 24, 2022
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.