Dynamic Analysis of a Single-Rotor Wind Turbine with Counter-Rotating Electric Generator under Variable Wind Speed
Dynamic Analysis of a Single-Rotor Wind Turbine with Counter-Rotating Electric Generator under...
Neagoe, Mircea;Saulescu, Radu;Jaliu, Codruta;Neagoe, Ion
2021-09-23 00:00:00
applied sciences Article Dynamic Analysis of a Single-Rotor Wind Turbine with Counter-Rotating Electric Generator under Variable Wind Speed 1 2 , 1 , 3 Mircea Neagoe , Radu Saulescu * , Codruta Jaliu * and Ion Neagoe Renewable Energy Systems and Recycling R&D Centre, Faculty of Product Design and Environment, Transilvania University of Brasov, 500036 Brasov, Romania; mneagoe@unitbv.ro Design of Mechanical Elements and Systems R&D Centre, Faculty of Product Design and Environment, Transilvania University of Brasov, 500036 Brasov, Romania Advanced Manufacturing Technologies and Systems R&D Centre, Faculty of Technological Engineering and Industrial Management, Transilvania University of Brasov, 500036 Brasov, Romania; neagoe_ion@unitbv.ro * Correspondence: rsaulescu@unitbv.ro (R.S.); cjaliu@unitbv.ro (C.J.); Tel.: +40-268-413-000 (R.S.) Abstract: This paper presents a theoretical study of the dynamic behaviour of a wind turbine con- sisting of a wind rotor, a speed increaser with fixed axes, and a counter-rotating electric generator, operating in variable wind conditions. In the first part, the dynamic analytical model of the wind turbine mechanical system is elaborated based on the dynamic equations associated with the compo- nent rigid bodies and the linear mechanical characteristics associated with the direct current (DC) generator and wind rotor. The paper proposes a method for identifying the coefficients of the wind rotor mechanical characteristics depending on the wind speed. The numerical simulations performed in Simulink-MATLAB by MathWorks on a case study of a 10 kW wind turbine highlight the variation Citation: Neagoe, M.; Saulescu, R.; with the time of the kinematic parameters (angular speeds and accelerations), torques and powers for Jaliu, C.; Neagoe, I. Dynamic Analysis wind system shafts, as well as the mechanical efficiency, both in transient and steady-state regimes, of a Single-Rotor Wind Turbine with considering variable wind speed. The analytical and numerical results are helpful for researchers, Counter-Rotating Electric Generator designers, developers, and practitioners of wind turbines aiming to optimise their construction and under Variable Wind Speed. Appl. Sci. functionality through virtual prototyping. 2021, 11, 8834. https://doi.org/ 10.3390/app11198834 Keywords: renewable energy; wind turbine; counter-rotating electric generator; dynamic modelling; simulation; variable wind speed Academic Editor: Daniel Villanueva Torres Received: 29 August 2021 1. Introduction Accepted: 20 September 2021 Published: 23 September 2021 In the global effort to achieve the ambitious targets for decarbonisation of the energy system, at a national and global level, wind energy plays a significant role now and a Publisher’s Note: MDPI stays neutral major one in the future. Thus, the European Union (EU) aims to move to 100% clean with regard to jurisdictional claims in energy by 2050 as an important step in achieving climate neutrality, the energy sector being published maps and institutional affil- responsible for more than 75% of greenhouse gas emissions (GHG) at the European level, iations. according to the European Green Deal [1]. This goal can be achieved by using renewable energy sources, a key role being granted to increasing wind production by improving wind energy systems, especially installed offshore. In all decarbonisation scenarios, which consider the high-level implementation of renewable energy systems, it is emphasized that Copyright: © 2021 by the authors. the main source of electricity generation will be wind power by 2050 [1,2] with a share of Licensee MDPI, Basel, Switzerland. over 36% of the total [3,4]. Thus, wind energy had a total installed capacity of 743 GW at This article is an open access article the end of 2020 [5], with an increase to over 6000 GW foreseen by 2050 [4], as wind power distributed under the terms and remains an efficient and affordable technology of producing clean electricity in a safe and conditions of the Creative Commons sustainable way. Energy management considering the variability of renewable energy Attribution (CC BY) license (https:// sources and the reliability of networks and systems facing utility grid outages remains a creativecommons.org/licenses/by/ challenge for energy systems with a high share of renewables [6–8]. 4.0/). Appl. Sci. 2021, 11, 8834. https://doi.org/10.3390/app11198834 https://www.mdpi.com/journal/applsci Appl. Sci. 2021, 11, 8834 2 of 21 The wind energy sector is gaining more and more popularity among researchers, developers and investors. They have paid attention to the behaviour of onshore and offshore wind systems and their components in different operating conditions. Their optimal design and modelling are permanent challenges in ensuring the high energy performance of wind systems, operating under variable wind conditions. Therefore, the dynamic behaviour of wind turbines is of significant interest as it influences significantly the conversion system functional performance, output power, and reliability. The dynamic modelling of wind turbines in order to identify and control their be- haviour or their functional optimization has drawn the attention of many researchers in recent decades. The research in this field is addressing either the dynamics of the entire wind turbine/farm or the dynamic modelling of a component of the wind conversion system: wind rotor, speed increaser, or electric generator. Different dynamic modelling approaches are presented in the literature, while the simulation is mainly performed with the MATLAB-Simulink software package. Cottura et al. present in [9] the modelling of a floating wind turbine under a broad spectrum of sea and wind conditions. The dynamic model is compared with the FAST reference model (fatigue, aerodynamics, structures, and turbulence), a reference software for modelling offshore wind turbines, the errors between the two models being reported as being below two percent. A similar concept is presented in [10] where the hydrodynamic performance of the floating foundation of an offshore wind turbine is analysed based on Reynolds-Averaged Navier-Stokes simulations. The FAST dynamic model allows the performance investigation of the floating platform under operational and storm conditions. A rigid multibody dynamic model for a floating offshore wind turbine and its dynamic responses are presented in [11]. The authors use the Euler–Lagrange equations for system motion, while the dynamic response under four load cases is validated against the FAST model. The dynamic of the onshore wind systems is addressed as well in the literature, referring mainly to general theoretical models, based on customised models that can be developed. For instance, Santoso and Le present in [12] a dynamic model that includes aerodynamic, mechanical, and electrical components of a turbine operating at a constant wind speed. The model is simulated in four case studies to prove its validity. Equivalent models of wind farms operating at constant wind speed are proposed in [13]. These dynamic models offer high accuracy of the dynamic response regarding the simulations of the energy system and a reduction in the simulation time compared to the detailed model of the actual wind farm. A dynamic model of a fixed-pitch angle wind turbine simulator is presented in [14], which includes different wind turbine profiles for which the mechanical power characteris- tics of the wind turbine are assigned. The model allows defining the mechanical power and torque as functions of the wind speed. A similar concept is presented in [15], where the Blade Element Method is used to determine the power coefficient of a turbine consisting of a wind rotor, a speed increaser, and a conventional electric generator. The model considers the hydrodynamic data for the rotor, the inertia characteristics of the whole system, fric- tional losses, and the electromagnetic torque of the generator. Qi et al. propose in [16] a method to improve the dynamic response of a wind turbine by a torque error feed-forward control and the blade-pitch angle servo control. The mechanical system model is based on the FAST code, the results being validated on a five megawatt wind turbine. The dynamic behaviour of wind turbines under stormy wind conditions is presented in [17]. The authors use the beam theory to couple the wind turbine dynamic model to the unsteady aerody- namic model to generate the dynamic response of the system. The results are simulated on two wind turbines of two and six megawatts. The dynamic model of a wind turbine without a gearbox is presented in [18], the simulation performed in MATLAB-Simulink considering load flow, fluctuations in wind speed, and transient and output power. The researchers in the field have paid particular attention to the dynamics of the gearbox, the literature proving that the dynamic behaviour of speed increasers is closely Appl. Sci. 2021, 11, 8834 3 of 21 related to the dynamic behaviour of the wind systems. A gear transmission of Ravigneaux type is used in [19] to propose a dynamic analysis method based on a general algorithm for determining the transmission ratio, transmission torques, and efficiency. Another method for dynamic modelling uses numerical integration of Runge-Kutta type [20], and considers nonlinear dynamic characteristics of a speed increaser with one input and one output. Another nonlinear dynamic model is presented in [21], which considers a planetary speed increaser with an input and an output for which the load distribution on the gears is studied, the algorithm being based on the lumped parameters method. To improve the load-sharing capacity on the component gear pairs, Zhu et al. present in [22] a dynamic model of a planetary speed increaser with flexible pins. The dynamic behaviour of the wind system is also studied using the lumped parameter model, in which the stiffness of the bodies is predicted using the finite element method. Another approach is proposed by Fan et al. in [23] that discusses the dynamics of a speed increaser depending on the power vs. speed curve; the dynamic effect due to different input powers on the mechanical characteristics of the speed increaser is also investigated. A dynamic analysis of a planetary speed increaser is developed in [24] using the torsional multibody model, used to investigate the transient response of the transmission. Different planetary speed increasers for wind and hydro applications are proposed and dynamically analysed in [25,26] as transmissions with one input and one output. A new planetary speed increaser with two inputs and one output is proposed by Lin et al. [27] and its dynamic responses are simulated using the fourth order Runge-Kutta method. The time-domain dynamic response of heavy-duty planetary speed increasers is studied in [28] by using the lateral–torsional coupling modelling method; the method is validated on a two megawatt wind turbine gearbox. Wang et al. developed in [29] a dynamic model for a multistage planetary gear transmission by using the lumped parameter method to obtain the load-sharing coefficients for each planet gear pair under variable input speed and internal excitation. Unlike the previously presented results that refer to gear transmissions used as speed increasers, ref. [30] proposes a new variant of a cycloidal planetary transmission for re- newable energy systems and analyses its dynamic behaviour, the efficiency values being experimentally validated. A general approach to the steady-state efficiency analysis of speed increasers with both one or two inputs and one or two outputs is proposed in [31]. The authors concluded that the in-parallel or split-power transmissions used in wind turbines with either two counter-rotating rotors or a counter-rotating generator have higher efficiency than serial transmissions. Another approach in dynamic modelling is the use of controllers adapted for wind turbines with a double-fed induction generator, which allows the estimation in real time of dynamic behaviour compensating for the external disturbances action [32]. The optimal design of proportional-integral controllers integrated in on-grid permanent magnet syn- chronous generators from variable-speed wind turbines is addressed by Qais et al. in [33] by proposing a transient search optimization algorithm. Aiming to improve the performance of the electric generators for wind turbines, a counter-rotating generator with permanent magnets for built environment applications is proposed and analysed in [34–36]; the counter-rotating generator is proved to have a higher efficiency than the conventional one, with a low starting torque, it is compact and scalable. The literature survey concludes that the dynamic behaviour is performed only for systems with one input and one output or two inputs and one output, i.e., wind turbines with a conventional electric generator. In the vast majority of the presented research, the wind rotor and generator have nonlinear models, which lead to a dynamic model with a high complexity. In addition, some onshore theoretical models consider the wind turbines operating under constant wind speed. Generally, the numerical simulations are performed on high-power wind systems using Matlab-Simulink. As a result, the authors did not identify in the literature relevant results regarding the generalized dynamic modelling Appl. Sci. 2021, 11, 8834 4 of 21 of the mechanical system for the class of wind turbines with single wind rotor and a counter-rotating electric generator, which would enable obtaining, in a simpler way, the dynamic response under variable wind speed. The paper aims to cover the gap by proposing a novel algorithm for dynamic mod- elling of single-rotor wind systems that include a counter-rotating electric generator and a speed increaser with one input (connection to the wind rotor) and two outputs (connec- tions to the rotor and stator of the electric generator), meant also to be used in real very attracting low-power applications, e.g., in the built environment. The power generated by the wind rotor is branched to the generator rotor and stator, a solution that brings several advantages compared to the conventional wind turbines (with fixed stator): higher mechanical efficiencies, a more compact speed increaser (with lower kinematic ratio), and a self-balancing electric generator in operation. The dynamic modelling is performed under variable wind conditions. It combines the classical equations associated with the rigid bodies with fixed-axis rotational motion (mechanical moments of inertia, kinematic transmission ratios, and the efficiency of the cylindrical gear set) with the linear equations associated with the mechanical characteristics for both the direct current (DC) generator and the wind rotor, respectively, on its quasilinear active working sector in operation. The linear equations of the wind rotor mechanical characteristic are expressed as functions of wind speed. The motion and efficiency equations in the dynamic regime are defined analytically and simulated for the case study of a 10 kW wind turbine, the numerical results validating the generalized theoretical model. The paper is organised as follows: Section 2 presents the configuration of the wind turbine with counter-rotating generator and the analytical model for angular speeds and kinematic ratio; Section 3 is devoted to the dynamic analytical modelling; in Section 4 the numerical simulations and analyses are performed for a specific scenario; and Section 5 provides the conclusions. 2. Problem Formulation Wind turbines with counter-rotating electric generator are characterised by a mechani- cal system with higher inertia versus the ones with conventional electric generator, due to the rotation of the generator stator, which usually is characterised by a higher mechanical moment of inertia than the generator rotor. Therefore, identifying the transient dynamic behaviour of these wind turbines when changing the wind speed is a challenge in expand- ing the implementation of wind turbine solutions with counter-rotating electric generators and also for their better operation. The modelling of the dynamic response of wind turbines with counter-rotating electric generator was further developed for a generic wind turbine including a simple gearbox. The analysed wind turbine consisted of a wind rotor R, a fixed axes speed increaser SI with one input and two outputs, and a counter-rotating electric generator G, characterised by the rotation of the rotor GR and stator GS in opposite directions, Figure 1. The speed increaser SI was derived from a cylindrical planetary gear set with one satellite gear, which functioned as a fixed axes mechanism obtained by connecting the satellite carrier H to frame 0. Thus, the mechanical power input in the speed increaser was achieved through a ring gear 2, which was connected to the wind rotor R and to the generator stator GS, which engaged with two or more evenly distributed gears 3. The gears 3 engaged simultaneously with gear 1, which ensured the transmission of mechanical power to the generator rotor GR. The ring gear 2 and gear 1 had the same revolute axis, namely the central axis. As a result, the input mechanical power was distributed on two branches to (Figure 1c): - the generator rotor GR, through the speed increaser SI, with speed amplification; - the generator stator GS, without changing the input speed due to the direct connection between the wind rotor R and the stator GS. Appl. Sci. 2021, 11, 8834 5 of 21 Figure 1. Single-rotor wind turbine with counter-rotating electric generator: (a) conceptual scheme; (b) kinematic scheme (upper-half front view); and (c) block scheme. The angular speeds of the gears and the kinematic ratios, under the conditions of the branched transmission of mechanical power from the input 2 R to the outputs 1 GR and 2 GS, can be obtained based on the scheme from Figure 1b: ! = = tan ; ! = ! (1) 1 1 1 GR ! = = tan ; ! = ! = ! (2) 2 2 2 R GS ! ! tan r z GR 1 1 2 2 i = = = = = (3) GR_R ! ! tan r z R 2 2 1 1 GS i = = 1 (4) GS_R where ! is the angular speed of gear x = 1 . . . 3; v —the peripheral linear speed on the x x pitch circle of radius r of gear x = 1 . . . 3; —the angle between the straight lines given x 1, 2 by the center of rotation of gears 1, 2 and the origin and the tip, respectively, of the speed vector v ; z —the teeth number of the gears 1, 2; i —the kinematic ratio (i.e., the ratio 1,2 1, 2 x_y of angular speeds) when the rotation motion is transmitted from body x to body y. In the operation of an electric generator, the relative angular speed of the rotor to the stator ! (referred to as the angular speed of the electric generator) is a characteristic parameter for the generated electric power: ! = ! ! = ! ! (5) G GR GS 1 2 As a result, the total amplification ratio of the angular speed i achieved by the wind G_R turbine with counter-rotating generator can be determined with the following relation: ! ! ! tan tan r z G GR GS 1 2 2 2 i = = = = 1 = 1 + (6) G_R ! ! tan r z R R 2 1 1 Appl. Sci. 2021, 11, 8834 6 of 21 The dynamic modelling of the wind turbine from Figure 1 was performed under the following premises: - the moving components (gears, the wind rotor, the rotor and stator of the electric generator) were rigid bodies with the mass distributed evenly and, also, geometrically symmetrical in relation to their own axis of rotation; therefore, the centre of mass of a body was a fixed point, located on the body fixed axis of rotation; - only the frictional losses in the gearing were further considered, while the frictions in the revolute joints, materialised by bearings with low friction coefficients (due to the rolling friction), were neglected; - the wind rotor and the electric generator were not adjusted during operation, which means that the pitch angle of the blades did not change in operation, and the adjust- ment parameters of the electric generator remained constant in operation; - the wind rotor and the electric generator had known mechanical characteristics of linear type with constant coefficients. The mechanical characteristic of a wind rotor is a complex 2D curve, which can be approximated with a linear function in the steady- state regime. Moreover, the DC generators are characterised by a linear dependence between the driving torque and the angular speed of the electric generator ! ; - the electrical losses inside the generator were neglected in this study. The main stages of the proposed dynamic response modelling of the wind turbine mechanical system are depicted in Figure 2 and further presented. Based on the conceptual diagram from Figure 1, the input parameters in this algorithm were the wind rotor radius, efficiencies of gear pairs and teeth numbers of the gears from the speed increaser, the torque-speed characteristic of the electric generator, and the inertial properties of the components. In the first stage, the kinematic modelling of the wind turbine mechanical system was performed by obtaining the transmitting functions for the angular speeds and the other angular speeds that are dependent on the independent speed of the wind rotor. For this mechanical system, three dynamic equations can be described, corresponding to the three rigid bodies to which the mechanical transmission can be reduced. The dynamic equations can be obtained by various approaches, in this case by using the Newton- Euler method. The mechanical characteristics (torque-angular speed dependence at a shaft level) of the wind rotor and the electric generator were added to the kinematic and dynamic equations of the mechanical system. This study considered the case of DC electric generators, characterized by linear characteristics modelled by linear functions, as well as by the equality in absolute value of the torques on its rotor and stator, both mobile with rotations in opposite directions. The mechanical characteristic of the wind rotor can be linearized on the active operating area, the coefficients of the linear function being dependent on the wind speed. These equations enable the calculation of the differential motion equation of the system that describes the behaviour in transient and steady-state regimes depending on the independent kinematic variable (the motion of the wind rotor). The motion equation can be solved by using Simulink-Matlab software and obtains the system dynamic response (i.e., variation over time of the parameters of independent motion). Once the dynamic response is established, all the other kinematic parameters and torques that are associated with the mechanical transmission shafts are obtained explicitly based on the previous set of equations, including highlighting the changes in mechanical efficiency during wind turbine operation. The proposed algorithm is a general one and can be applied to any wind turbine with a single wind rotor and a counter-rotating electric generator, regardless of whether the mechanical characteristic of the wind rotor is linearized or not, the speed increaser has fixed axes or is of planetary type, and the generator is either a DC or an AC. For the sake of simplicity and better understanding, the simplified case of fixed axes speed increaser and linear mechanical characteristics is considered in this paper. Appl. Sci. 2021, 11, 8834 7 of 21 Figure 2. Flowchart of the proposed dynamic modelling for single-rotor wind turbines with counter-rotating electric generator. 3. Dynamic Modelling The dynamic equations of a general system of motor(s)-mechanism-effector(s) type describe the system motion under the action of actuation and resistance forces/torques. The dynamic equations of a wind turbine under the premises mentioned in Section 2 are homogeneous linear differential equations of second order. The angular acceleration and speed of the wind rotor interfere with and define the independent motion of the mechanical system. Appl. Sci. 2021, 11, 8834 8 of 21 The dynamic modelling method uses the equations of the Newton-Euler formalism and implies the prior isolation of each body by replacing the connections between the bodies by the corresponding reaction forces. It is followed by the description of the Newton- Euler equations for each body, according to the general expression when the origin of the coordinate system attached to the body coincides with the body centre of mass cm [37]: F mI 0 a 0 3 cm = + (7) T 0 J " w J ! cm cm where F is the resultant force vector acting on the centre of mass, m—the body mass, I —the 3 3 identity matrix, a —acceleration vector of the centre of mass, T—resultant torque cm vector acting on the centre of mass, J —moment of inertia defined about the centre of cm mass, !—angular speed vector of the body, and "—angular acceleration vector of the body. In the case of symmetrical bodies with a fixed axis of rotation (i.e., the centre of mass cm is a fixed point on the axis of rotation), Equation (7) can be simplified in the following scalar form: T = J # (8) where T is the resultant torque acting on body, J—moment of inertia around the body motion axis, and "—angular acceleration of the body. 3.1. Dynamic Equations of Component Bodies Based on the scheme from Figure 1a, the considered wind turbine can be decomposed into the following rigid bodies: - body B1: the assembly consisting of the sun gear 1, the generator rotor GR, and the connecting shaft, Figure 3a; - body B2: the assembly wind rotor R—ring gear 2—generator stator GS, Figure 3b; - a number s of gears 3 and their shafts (body B3), evenly distributed around the central axis, Figure 3c. The positive direction of the angular speed and torque vectors for all the bodies B1 . . . B3 is defined to the right (Figure 1), while J denotes the axial moment of inertia of the body x = 1 . . . 3, ! —the angular speed of the body x, and T —the resultant torque acting x x on the body x. Thus, considering the body B1 characterised by the fixed-rigid connection between gear 1 and the generator rotor RG, the following equations can be written (Figure 3a): ! = ! (9) 1 GR J # = T T (10) 1 1 GR 1 Similarly, the kinematic and dynamic equations of the B2 body, characterised by the connections R 2 GS, can be described by (Figure 3b): ! = ! = ! (11) R 2 GS J # = T T + T (12) 2 2 R 2 GS The mechanical power is transmitted from ring gear 2 to gear 1 through s theoretically equal flows, corresponding to s number of gears 3 that are mounted in parallel between gears 2 and 1. As a result, the body B3 is driven theoretically by a torque T defined by relation (13): T = i (13) 32 2_3 2_3 3 Appl. Sci. 2021, 11, 8834 9 of 21 Figure 3. Dynamic scheme of: (a) body B1; (b) body B2; and (c) body B3. Appl. Sci. 2021, 11, 8834 10 of 21 which comes from the energetic equilibrium equation with friction for the gear pair 2–3: T ! = s T ! (14) 2 2 2_3 3 32 3 where i = ! /! = z /z is the kinematic ratio of the gear pair 2–3, and —the 2_3 2 3 3 2 2_3 efficiency of the gear pair 2–3. Gear 3 is also subjected to a reaction torque T from gear 1: T = i (15) 31 1_3 3_1 defined as well based on the energetic equilibrium equation with friction for the gear pair 3–1: s T ! = T ! (16) 3 31 3 1 1 3_1 where i = ! /! = z /z is the kinematic ratio of the gear pair 1–3, and —the 1_3 1 3 3 1 3_1 efficiency of the gear pair 3–1. As a result, the dynamic equation for the body B3 is: J # = T + T (17) 3 3 32 31 which by considering Equations (13) and (15) becomes: s J # = T i + T i (18) 3 3 3 2 2_3 1 1_3 2_3 3_1 Relation (18) models the transmission of mechanical power from gear 2 to gear 1 in the general case of considering the inertial effects of the body B3 and the impact of gear friction; if the mass of body 3 is neglected (i.e., J = 0) or if the turbine is operating in a steady-state regime (i.e., # = 0), Equation (18) takes the particular form: T i + T = 0 (19) 2 2_1 2_1 1 which expresses the energetic equilibrium condition of the speed increaser SI in the premise of considering friction in gear pairs, in which: ! z 2 1 i = = i i = (20) 2_1 2_3 3_1 ! z 1 2 and = (21) 2_1 2_3 3_1 3.2. Mechanical Characteristics The set of dynamic equations of the three bodies B1 . . . B3 is completed with the linear mechanical characteristics with constant coefficients of the wind rotor and the counter- rotating electric generator, respectively: - the wind rotor R T = a ! + b , 0 ! , a > 0, b > 0 (22) R R R R R R R - the electric generator G T = a ! + b , ! , a > 0, b < 0 (23) G G G G G G G G Appl. Sci. 2021, 11, 8834 11 of 21 where a , b , a , b are the constant coefficients under the steady-state regime, and, by R R G G definition, T = T . Moreover, the functional specificity of an electric generator ensures G GR the torque equilibrium condition between the rotor GR and the stator GS: T + T = 0 (24) GR GS According to the chosen positive direction (see Figure 3), the mechanical characteristic of the wind rotor is active in quadrant I (T > 0 and ! > 0), while for the electric generator R R in quadrant II, (T > 0 and ! < 0) for absolute values of the angular speed ! larger than G G G the critical value jb /a j, which delimits the operating modes as motor and generator of G G the DC machine, Figure 4. Therefore, in the dynamic analysis, the electric machine will be considered in idle functioning regime (i.e., T = 0) until the required operating speed as a generator is reached: T = 0 for ! > (25) G G Figure 4. Linear mechanical characteristics of a wind rotor (R) and a DC generator (G). In the present study, it was assumed that the electric generator was not adjusted during operation, and the pitch angle of the wind rotor blades was not changed. Instead, the mechanical characteristic of the wind rotor changes with the variation of the wind speed, as the mechanical power P generated at the wind rotor shaft depends on wind speed value [38]: 2 3 P = pC r v (26) R p R w where is the air density, C —aerodynamic power coefficient, r —radius of the wind rotor, and v —the wind speed. In the general case, the coefficient Cp depends on the wind speed v , the angular speed of the wind rotor ! , and the blade pitch angle . Since, in this study, the pitch angle was considered constant = 0 , the general relation of the power coefficient Cp [38–40] is obtained through particularisation in the following form: C = c c e + c (27) p 1 3 5 i Appl. Sci. 2021, 11, 8834 12 of 21 where is the tip speed ratio: ! r R R = (28) and 1 1 = c (29) where c = 0.5176, c = 116, c = 5, c = 21, c = 0.0068, and c = 0.035. 1 2 3 4 5 6 Thus, the mechanical characteristic of a wind rotor T = T (! , v ) can be described R R R analytically by Equation (30): P 1 c v c v c ( c ) R 1 w 2 w 3 2 4 6 ! r R R T = = p r v c c c e + c (30) R 2 6 3 5 R w ! 2 ! r ! r R R R R R Considering the air density = 1.225 kg/m , the mechanical characteristic of a wind rotor with the radius r = 5 m is illustrated in Figure 5 for different values of wind speed v . There is a distinct evolution of the torque T on the three zones A, B and C (Figure 5a), w R with approximately linear shapes, rounded at the transition from one zone to another. Thus, the torque T remains constant with the increase in the angular velocity ! up to a R R threshold value of the angular speed (which increases with the increase in the wind speed, zone A), followed by an ascending evolution to the maximum value (max T , zone B) and a lower slope decrease on zone C—the normal operating area of the wind rotor. It can also be noticed that the maximum power points (max P ) are found in zone C, at higher values of the angular speed ! than those corresponding to the maximum torque points (max T ). R R Moreover, regardless of wind speed, the maximum power points are located at the limit of the approximately linear sector of the mechanical characteristic from zone C. Therefore, it is reasonable to consider the hypothesis of mechanical characteristics of wind turbines as linear functions with constant coefficients at a given value of the wind speed, under the condition that the wind turbine operates at optimal angular speed values (corresponding to the maximum power point) or higher. Considering the curves in zone C approximated by linear functions, described accord- ing to Equation (22), the influence of increasing wind speed on the wind rotor mechanical characteristic can be summarised as follows (Figure 5b): it causes the increase in the angular speed during idle operation (i.e, TR = 0), meaning the increase in the bR/aR value. it leads to the increase in the characteristic slope and to the increase in the bR value, implicitly. As a result, both coefficients a and b are directly influenced by the wind speed and R R thus the wind rotor operates under a different mechanical characteristic when the wind changes its speed. Appl. Sci. 2021, 11, 8834 13 of 21 Figure 5. The influence of wind speed on the mechanical characteristic of a wind rotor: (a) mechanical characteristic zones; (b) linearized active sector of mechanical characteristics. 3.3. System Motion Equation The wind system motion in the dynamic regime is described by a second-order differential equation represented as a function of the independent input motion of the wind . .. rotor R, i.e., the angular speed ! = ' and angular acceleration # = ' , where ' is R R R R R . .. 2 2 the angular displacement of the wind rotor, ' = d' /dt and ' = d ' /dt . R R R R According to Equations (10) and (18), the torques T and T are obtained: 1 2 T = T J # (31) 1 G 1 1 s J # T i 3 3 3 1 1_3 3_1 T = (32) 2_3 2_3 Appl. Sci. 2021, 11, 8834 14 of 21 and considering Equations (11), (12), and (31), the angular acceleration is obtained: 1_2 T + T 1 R G 2_1 # = (33) 2 2 i i 1_2 3_2 J + J + s J 1 2 3 3 2_1 2_3 in which the following obvious replacements are considered: # = i # ; # = i # ; T = T (34) 1 1_2 2 3 3_2 2 GS G Equation (35) is obtained from Equations (23), (5), and (11): T = a (i 1)! + b (35) G G 1_2 R G The motion equation of the wind system is obtained replacing Equations (22) and (35) in (33): h i h i i i 1_2 1_2 a + a (i 1) 1 ! + b + b 1 R G 1_2 R R G 2_1 2_1 # = (36) 2 2 i i 1_2 3_2 J + J + s J 1 2 3 3 2_1 2_3 The following a priori known constant parameters interfere in the differential Equation (36): a , b , a , b , J , J , J , i , i , (37) R R G G 1 2 3 1_2 3_2, 2_1 2_3 in which the parameters a and b are dependent on the wind speed, according to linear R R trend lines in Figure 5b. . .. The time variation of the independent parameters (' , ' , ' ) is obtained solving R R R Equation (36) under given initial conditions, which describes the evolution in time of the kinematic (displacements, angular speeds, and accelerations) and dynamic behaviour (torques, powers, and efficiency) of the wind system and its components. Equation (36) is numerically solved using Simulink-MATLAB by MathWorks, aspects of which are presented in Section 4. 3.4. Mechanical Efficiency The energy loss due to friction in a mechanical system is expressed by mechanical efficiency, as a measure of how the mechanical input power is transmitted through the mechanism to the outputs. The mechanical efficiency is a variable quantity in the tran- sient regime, significantly influenced by the system’s inertial properties, which tends asymptotically towards a maximum value specific to the steady-state system operation. Thus, the relation for the mechanical efficiency of the wind turbine is established starting from its definition, in which Equations (22) and (35) are replaced: T ! a (i 1)! + b G G G 1_2 R G = = (i 1) (38) 1_2 T ! a ! + b R R R R R Equation (36) is solved as a function of ! and the mechanical efficiency in the transient regime is obtained after the replacement of the obtained solution in Equation (38): (i 1)a b (i 1) a (b # J ) 1_2 R G 1_2 G R R = (39) i i 1_2 1_2 1 a b (i 1) 1 a b a # J R G 1_2 G R R R 2_1 2_1 where J* is the equivalent mechanical moment of inertia of the system reduced at body 2: 2 2 1_2 3_2 J = J + J + s J (40) 1 2 3 3 2_1 2_3 Appl. Sci. 2021, 11, 8834 15 of 21 Equation (39) shows the dependence of efficiency on the angular acceleration # of the wind rotor; in a steady-state regime (i.e., # = 0), the expression of the mechanical efficiency can be simplified as follows: i 1 1_2 = (41) 2_1 1_2 2_1 Unlike the conventional wind turbines with a wind rotor and conventional generator (with fixed stator), in which the speed increaser has the efficiency independent of the speed amplification ratio, the stationary mechanical efficiency of wind turbines with counter- rotating generator depends on both the efficiency of the speed increaser SI with fixed axes (i.e., = ) and the kinematic ratio i , according to Equation (41). Given that 2_1 2_3 3_1 1_2 the kinematic ratio i has a negative supraunitary value and < 1, it is obvious that 1_2 2_1 > . Thus, it can be concluded that wind turbines with counter-rotating generator 2_1 have a better mechanical efficiency in a steady-state regime than the conventional systems that integrate the same speed increaser. 4. Results and Discussions The numerical simulations of the dynamic model presented in Section 3, developed for the wind turbine with counter-rotating electric generator described in Section 2, aim to highlight the evolution in time of the mechanical power parameters (i.e., torque and angular speed) for input and output shafts, as well as the angular acceleration and the system mechanical efficiency, in the conditions of sudden changes of the wind speed. Thus, we considered a wind turbine with a rated power of 10 kW at a nominal wind speed of 8 m/s, characterised by the parameters from Table 1, in a operating scenario in which the wind turbine started under the action of a 8 m/s wind (stage I), after which the wind speed dropped sharply to 6 m/s after 8 s (stage II) and then returned to 8 m/s after 15 s (stage III). Since the linear model adopted for the mechanical characteristic of the wind rotor is valid only on the useful area of this characteristic (see Figure 5, zone C), in stage I the initial starting phase was ignored (which is not the object of this research) and the time of 0 s was chosen at the moment when the angular speed of the wind rotor reached the value corresponding to the maximum power max P . Table 1. The parameters of the 10 kW wind turbine with counter-rotating generator. Component Parameter Value Unit Wind rotor v = 8 m/s a 111.16 Nm/s b 2388.2 Nm v = 6 m/s a 83.208 Nm/s b 1341 Nm Speed increaser i 9 - 1_2 i 2.25 - 3_2 i 4 - 1_3 = 0.975 - 2_3 3_1 _ 0.9506 - 2 1 s 3 - Electric generator a 3 Nm/s b 395 Nm Inertial parameters J 2.5 kgm J 75 kgm J 0.25 kgm 3 Appl. Sci. 2021, 11, 8834 16 of 21 The dynamic analytical model of the wind turbine was implemented in the Simulink module from Matlab by MathWorks. The obtained graphical results including the mechan- ical efficiency of the wind system are systematised in: Figure 6 for the input (wind rotor R) and output components (electric generator G), Figure 7 for the rotor GR and the stator GS of the electric generator, and the distributions of the torque and power of the wind rotor on the two branches towards the speed increaser input and towards the stator GS are illustrated in Figure 8. Figure 6. The dynamic behaviour of the wind rotor R and electric generator G in relation to wind speed modification: (a) angular speed; (b) angular acceleration; (c) torque; (d) mechanical power; and (e) mechanical efficiency. Appl. Sci. 2021, 11, 8834 17 of 21 Figure 7. The dynamic behaviour of the generator rotor GR and stator GS in relation to wind speed modification: (a) angular speed; (b) angular acceleration; (c) torque; and (d) mechanical power. Figure 8. The dynamic distribution on gear 2 and the generator stator GS of the: (a) torque and (b) mechanical power generated by the wind rotor R. In stage I of the considered operating scenario, the wind turbine passed through a transient period until entering the steady-state, i.e., characterised by constant values of the kinematic parameters and torques, Figure 6a–d. Typically, the beginning of the steady-state regime is identified when the angular accelerations become null, Figure 6b. In this transient stage, the system was accelerated, a significant part of the wind rotor power P was used to overcome the inertial resistance of the mechanical components and the accumulation of kinetic energy, implicitly. The electric generator started producing electricity only when the speed ! became equal to the value b /a = 131.67 rad/s (see also Figure 4), shortly (about 0.1 s) after G G the entry of the wind rotor into the active area of its mechanical characteristic. At each operating time, the ratio between the angular speeds ! and ! and the ratio between G R Appl. Sci. 2021, 11, 8834 18 of 21 the angular accelerations # and # , respectively, was constant and equal in this case to G R i = 10. G_R In the steady-state operating regime during 4 to 8 s, the electric generator was operated with a power of 10 kW (Figure 6d) at an angular speed = 153.4 rad/s (Figure 6d). The decrease in the wind speed to 6 m/s after 8 s of operation (Stage II) caused the change in the mechanical characteristic of the wind rotor (see Table 1) and also the crossing of a transient stage (of about 3 s) towards a new steady-state operation, Figure 6a–d. The significant decrease in the wind rotor power P to ~2.67 kW and of the driving power of the electric generator P to ~2.56 kW, i.e., a reduction of ~25% of the rated power when the wind speed has dropped to only 75% of its nominal value, is noted in Figure 6d. This significant decrease in power is due mainly to the large decrease in torques (Figure 6c) and less of the angular speeds (Figure 6a). It is also worth noting the atypical evolution of the mechanical efficiency , which became supraunitary under the conditions of the definition from Equation (37): according to Figure 6d, the power of the wind rotor P decreased suddenly with the decrease in the wind speed, but the power P changed progressively due to the active effect of the kinetic energy, accumulated in the previous stage, which was added to the mechanical energy produced by the wind rotor. The efficiency in a steady-state regime was higher than the efficiency of the speed increaser ( ), i.e., 95.53% vs. 95.06%. 2_1 In stage III of the numerical simulation scenario, the wind speed returned suddenly to the nominal value v = 8 m/s, after 15 s of operation. The variation in the functional parameters was relatively similar to the one from stage II, symmetrically to the horizontal axis. A sudden decrease in efficiency can be noted (Figure 6e) given that the power of the wind rotor was used at the beginning mainly to accelerate the mechanical system and less to increase the power P . The evolution in time of the kinematic parameters and torques for the two mobile components of the electric generator, in the three stages of the simulation scenario, are presented in Figure 7. The generator rotor GR had an angular speed increased by i = 9 GR_R and higher than speed of the stator GS, implicitly (i = 1), Figure 6a. The angular GS_R accelerations # and # (Figure 7b) had similar evolutions to those illustrated in Figure 6b, GR GS given that # = # and # = # + # , which are derived from Equations (11) and (5), GS GR G GS respectively. The symmetry of the torques curves for the two components of the electric generator (Figure 7c), characterised by the connection relationship from Equation (24), could also be observed. Since the torques T and T were equal in absolute value, the variation of the GS GR powers P and P depended significantly on the values of the angular speeds ! and GS GR GS ! . As a result, the leading share of power was brought by the rotor GR, characterised by GR an angular speed higher than the stator GS speed; at the same time, the rotor GR also had the most significant power drop with the decrease in wind speed in stage II, Figure 7d. The torque T generated by the wind rotor R was dynamically distributed on two branches to gear 2 (speed increaser input) and the generator stator GS, the relation between these torques being influenced by the system inertia in the acceleration/deceleration phases, according to the dynamic relations from Equations (10), (12), and (18). Thus, in the transient phase of stage I, the torque T was used to accelerate the system and to balance the inertial resistances dynamically, implicitly, which were due to the mechanical moments of inertia J and J , on the one hand, and J , on the other hand, Figure 8a. The resistances generated 1 3 2 by the gearing friction forces also interfered in this process. Once the electric generator was put into operation, the resistant mechanical torque of the generator was added to the resistances mentioned above. The active effect of the kinetic energy accumulated in stage I can be observed at the beginning of stage II (Figure 8a), the torque T being higher than T . 2 R Similar evolutions and conclusions can be found for the powers P , P , and P , according R 2 GS to Figure 8b. Appl. Sci. 2021, 11, 8834 19 of 21 5. Conclusions This paper presented a generalized dynamic modelling approach of the mechanical system of a single-rotor wind turbine with counter-rotating DC generator, which integrates a mechanical speed increaser on the power flow to the generator rotor GR and a direct connection of the generator stator GS to the wind rotor R. The proposed modelling algo- rithm considered, besides the dynamic equations of the component rigid bodies, the linear mechanical characteristics of the electric generator and wind rotor. The analytical study and the numerical simulations of the considered case study in a functional scenario with three stages drew the following conclusions: - The proposed dynamic modelling algorithm, synthetically explained in Figure 2 and detailed in Section 3, is a novel and general approach for the class of wind turbines with a single wind rotor and a counter-rotating electric generator. It enabled us to derive the motion equation and obtain the dynamic response and operating point of the mechanical system in a number and a well-defined sequence of steps, regardless of the type of components of the wind system. - The proposed modelling for the linearization of the active sector of the mechanical characteristic of the wind rotor simplified the analytical modelling of the dynamic response, without introducing significant errors in relation to their nonlinear model regardless of the value of wind speed v : the obtained linear functions are character- ized by higher values of the statistical parameter R-squared (R > 0.998 for the case study of a 10 kW wind turbine, Figure 5b). - The proposed analytical approach enabled us to identify the wind system dynamic behaviour at wind speed change both in a transient regime and a steady-state regime, in a particular case characterised by zero angular accelerations. - The use of a counter-rotating generator in a wind turbine has the advantage of higher mechanical efficiency and kinematic ratio i than in a wind turbine of identical G_R power that contains a conventional electric generator (with fixed stator). - The proposed diagrams depicted in Figures 6–8, i.e., the variation of the mechani- cal power parameters, enabled us to draw valuable conclusions for the functional optimization of the wind turbine. The authors aim to extend in future the simplified modelling of the mechanical characteristic of the wind rotor through a succession of linear functions covering the entire range of angular speed ! variation, which will enable the complete identification of the dynamic behaviour in the starting phase. We also intend to validate the theoretical results by using specialised rigs experimentally. Author Contributions: Conceptualization, M.N. and R.S.; methodology, M.N., R.S. and C.J.; soft- ware, M.N. and R.S.; validation, M.N., R.S., C.J. and I.N.; formal analysis, M.N., R.S., C.J. and I.N.; investigation, M.N., R.S., C.J. and I.N.; writing—original draft preparation, M.N., R.S., C.J. and I.N.; writing—review and editing, M.N., R.S., C.J. and I.N.; visualization, M.N., R.S., C.J. and I.N.; supervision, M.N. and C.J. All authors have read and agreed to the published version of the manuscript. Funding: This research received no external funding. Institutional Review Board Statement: Not applicable. Informed Consent Statement: Not applicable. Conflicts of Interest: The authors declare no conflict of interest. Appl. Sci. 2021, 11, 8834 20 of 21 Nomenclature a, b Coefficients of mechanical characteristics a Acceleration vector of mass centre cm B Body DC Direct current F Force G Electric generator GR Electric generator rotor GS Electric generator stator H Satellite carrier I Kinematic ratio I Identity matrix J Moment of inertia J* Equivalent mechanical moment of inertia m Mass P Power R Wind rotor r Radius of the gear pitch circle SI Speed increaser T Torque v Linear speed v Wind speed z Gear teeth number Angle of the speed vector " Angular acceleration Mechanical efficiency ! Angular speed References 1. European Commission. The European Green Deal. Available online: https://ec.europa.eu/info/sites/default/files/european- green-deal-communication_en.pdf (accessed on 15 September 2021). 2. European Commission. Energy. Roadmap 2050. Available online: https://ec.europa.eu/energy/sites/ener/files/documents/20 12_energy_roadmap_2050_en_0.pdf (accessed on 15 September 2021). 3. International Renewable Energy Agency. Global energy transformation: A roadmap to 2050. Available online: https://www. irena.org/-/media/Files/IRENA/Agency/Publication/2018/Apr/IRENA_Report_GET_2018.pdf (accessed on 15 September 2021). 4. International Renewable Energy Agency. Global Renewables Outlook: Energy Transformation 2050. Available online: https: //www.irena.org/publications/2020/Apr/Global-Renewables-Outlook-2020 (accessed on 15 September 2021). 5. Global Wind Energy Council (GWEC). Global Wind Report 2021. Available online: https://gwec.net/wp-content/uploads/2021 /03/GWEC-Global-Wind-Report-2021.pdf (accessed on 15 September 2021). 6. Tostado-Véliz, M.; Icaza-Alvarez, D.; Jurado, F. A novel methodology for optimal sizing photovoltaic-battery systems in smart homes considering grid outages and demand response. Renew. Energ. 2021, 170, 884–896. [CrossRef] 7. Zamani, R.; Golshan, M.E.H.; Alhelou, H.H.; Hatziargyriou, N. A Novel Synchronous DGs Islanding Detection Method based on Online Dynamic Features Extraction. Electr. Power Syst. Res. 2021, 195, 107180. [CrossRef] 8. Alhelou, H.H.; Golshan, M.E.H.; Zamani, R.; Moghaddam, M.P.; Njenda, T.C.; Siano, P.; Marzband, M. An Improved UFLS Scheme based on Estimated Minimum Frequency and Power Deficit. In Proceedings of the IEEE Milan PowerTech, Milan, Italy, 23–27 June 2019; IEEE: Milan, Italy, 2019; pp. 1–6. [CrossRef] 9. Cottura, L.; Caradonna, R.; Ghigo, A.; Novo, R.; Bracco, G.; Mattiazzo, G. Dynamic Modeling of an Offshore Floating Wind Turbine for Application in the Mediterranean Sea. Energies 2021, 14, 248. [CrossRef] 10. Jiang, Y.; Hu, G.; Zong, Z.; Zou, L.; Jin, G. Influence of an Integral Heave Plate on the Dynamic Response of Floating Offshore Wind Turbine Under Operational and Storm Conditions. Energies 2020, 13, 6122. [CrossRef] 11. Bagherian, V.; Salehi, M.; Mahzoon, M. Rigid multibody dynamic modeling for a semi-submersible wind turbine. Energ. Convers. Manag. 2021, 244, 114399. [CrossRef] 12. Santoso, S.; Le, H. Fundamental time–Domain wind turbine models for wind power studies. Renew. Energy 2007, 32, 2436–2452. [CrossRef] 13. Fernández-Ramírez, L.; Saenz, J.; Jurado, F. Dynamic models of wind farms with fixed speed wind turbines. Renew. Energy 2006, 31, 1203–1230. [CrossRef] Appl. Sci. 2021, 11, 8834 21 of 21 14. Jansuya, P.; Kumsuwan, Y. Design of MATLAB/Simulink Modeling of Fixed-pitch Angle Wind Turbine Simulator. Energy Procedia 2013, 34, 362–370. [CrossRef] 15. Amarante Mesquita, A.L.; Amarante Mesquita, A.L.; Coutinho Palheta, F.; Pinheiro Vaz, J.R.; Girão de Morais, M.V.; Gonçalves, C. A methodology for the transient behavior of horizontal axis hydrokinetic turbines. Energy Convers. Manag. 2014, 87, 1261–1268. [CrossRef] 16. Qi, L.; Zheng, L.; Bai, X.; Chen, Q.; Chen, J.; Chen, Y. Nonlinear Maximum Power Point Tracking Control Method for Wind Turbines Considering Dynamics. Appl. Sci. 2020, 10, 811. [CrossRef] 17. Han, R.; Wang, L.; Wang, T.; Gao, Z.; Wu, J. Study of Dynamic Response Characteristics of the Wind Turbine Based on Measured Power Spectrum in the Eyewall Region of Typhoons. Appl. Sci. 2019, 9, 2392. [CrossRef] 18. Oyekola, P.; Mohamed, A.; Pumwa, J. Renewable Energy: Dynamic Modelling of a Wind Turbine. Int. J. Innov. Technol. Explor. Eng. 2019, 9, 9. [CrossRef] 19. Mathis, R.; Rémond, Y. Kinematic and dynamic simulation of epicyclic gear trains. Mech. Mach. Theory 2009, 44, 412–424. [CrossRef] 20. Xiang, L.; Gao, N.; Hu, A. Dynamic analysis of a planetary gear system with multiple nonlinear parameters. J. Comput. Appl. Math. 2017, 327, 325–340. [CrossRef] 21. Dong, H.; Zhang, C.; Wang, D.; Xu, S.; Qiu, J. Dynamic characteristics of gear box with PGT for wind turbine. Procedia Comput. Sci. 2017, 109, 801–808. [CrossRef] 22. Zhu, C.; Xu, X.; Liu, H.; Luo, T.; Zhai, H. Research on dynamical characteristics of wind turbine gearboxes with flexible pins. Renew. Energy 2014, 68, 724–732. [CrossRef] 23. Fan, Z.; Zhu, C.; Li, X.; Liang, C. The transmission characteristic for the improved wind turbine gearbox. Energy Sci. Eng. 2019, 7, 1368–1378. [CrossRef] 24. Shi, W.; Kim, C.; Chung, C.; Park, H. Dynamic Modeling and Analysis of a Wind Turbine Drivetrain Using the Torsional Dynamic Model. Int. J. Precis. Eng. Manuf. 2012, 14, 153–159. [CrossRef] 25. Jaliu, C.; Diaconescu, D.V.; Neagoe, M.; Saulescu, R. Dynamic features of speed increasers from mechatronic wind and hydro systems. Part I: Structure kinematics. In Proceedings of the EUCOMES 2008—The 2nd European Conference on Mechanism Science, Cassino, Italy, 17–20 September 2008; pp. 351–359. [CrossRef] 26. Jaliu, C.; Diaconescu, D.V.; Neagoe, M.; Saulescu, R. Dynamic features of speed increasers from mechatronic wind and hydro systems. Part II: Dynamic aspects. In Proceedings of the EUCOMES 2008—The 2nd European Conference on Mechanism Science, Cassino, Italy, 17–20 September 2008; pp. 361–368. [CrossRef] 27. Lin, A.-D.; Hung, T.-P.; Kuang, J.-H.; Tsai, H.-A. Power Flow Analysis on the Dual Input Transmission Mechanism of Small Wind Turbine Systems. Appl. Sci. 2020, 10, 7333. [CrossRef] 28. Wu, J.; Zhou, Y.; Jiang, W.; Chen, X. Time-Domain Dynamic Modeling and Analysis of Complex Heavy-Duty Gearbox Considering Floating Effect. Appl. Sci. 2021, 11, 6876. [CrossRef] 29. Wang, J.; Yang, S.; Liu, Y.; Mo, R. Analysis of Load-Sharing Behavior of the Multistage Planetary Gear Train Used in Wind Generators: Effects of Random Wind Load. Appl. Sci. 2019, 9, 5501. [CrossRef] 30. Neagoe, M.; Diaconescu, D.V.; Jaliu, C.; Pascale, L.; Saulescu, R.; Sisca, S. On a new cycloidal planetary gear used to fit mechatronic systems of RES. In Proceedings of the 11th International Conference on Optimization of Electrical and Electronic Equipment, Brasov, Romania, 22–24 May 2008; pp. 439–448. [CrossRef] 31. Neagoe, M.; Saulescu, R.; Jaliu, C.; Simionescu, P.A. A Generalized Approach to the Steady-State Efficiency Analysis of Torque- Adding Transmissions Used in Renewable Energy Systems. Energies 2020, 13, 4568. [CrossRef] 32. Song, Z.; Shi, T.; Xia, C.; Chen, W. A novel adaptive control scheme for dynamic performance improvement of DFIG-Based wind turbines. Energy 2012, 38, 104–117. [CrossRef] 33. Qais, M.H.; Hasanien, H.M.; Alghuwainem, S. Optimal Transient Search Algorithm-Based PI Controllers for Enhancing Low Voltage Ride-Through Ability of Grid-Linked PMSG-Based Wind Turbine. Electronics 2020, 9, 1807. [CrossRef] 34. Booker, J.; Mellor, P.H.; Wrobel, R.; Drury, D. A compact, high efficiency contra-rotating generator suitable for wind turbines in the urban environment. Renew. Energy 2010, 35, 2027–2033. [CrossRef] 35. Neagoe, M.; Saulescu, R.; Jaliu, C. Design and Simulation of a 1 DOF Planetary Speed Increaser for Counter-Rotating Wind Turbines with Counter-Rotating Electric Generators. Energies 2019, 12, 1754. [CrossRef] 36. Saulescu, R.; Neagoe, M.; Jaliu, C.; Munteanu, O. A Comparative Performance Analysis of Counter-Rotating Dual-Rotor Wind Turbines with Speed-Adding Increasers. Energies 2021, 14, 2594. [CrossRef] 37. Hahn, H. Rigid Body Dynamics of Mechanisms. 1 Theoretical Basis; Springer: Berlin/Heidelberg, Germany, 2002; ISBN 9783540423737. 38. Kong, X.; Ma, L.; Liu, X.; Abdelbaky, M.A.; Wu, Q. Wind Turbine Control Using Nonlinear Economic Model Predictive Control over All Operating Regions. Energies 2020, 13, 184. [CrossRef] 39. Petkovic, ´ D.; Cojbašic, ˇ Ž.; Nikolic, ´ V. Adaptive neuro-fuzzy approach for wind turbine power coefficient estimation. Renew. Sustain. Energy Rev. 2013, 28, 191–195. [CrossRef] 40. Rahman, S.; Akther, S.; Hoque, H.E. Comparison of Different Pitch Controller in Wind Farm for Integrated Power System. Am. J. Eng. Res. 2018, 7, 288–299. [CrossRef]
http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png
Applied Sciences
Multidisciplinary Digital Publishing Institute
http://www.deepdyve.com/lp/multidisciplinary-digital-publishing-institute/dynamic-analysis-of-a-single-rotor-wind-turbine-with-counter-rotating-VHtCUuBMIy