Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

An Investigation of the Temperature-Drift Effect on Strain Measurement of Concrete Beams

An Investigation of the Temperature-Drift Effect on Strain Measurement of Concrete Beams applied sciences Article An Investigation of the Temperature-Drift E ect on Strain Measurement of Concrete Beams Yiching Lin * , Yu-Ting Liu and Yu-Wen Chang Department of Civil Engineering, National Chung Hsing University, Taichung 402, Taiwan; ruliner1107@gmail.com (Y.-T.L.); winnie83216@gmail.com (Y.-W.C.) * Correspondence: yiching@nchu.edu.tw Received: 8 March 2019; Accepted: 15 April 2019; Published: 22 April 2019 Abstract: This study investigates the temperature-drift e ect on strain measurement of concrete beams and proposes a method for determination of the mechanical strain of stressed concrete beams. In the study, wireless electrical resistance strain gauges were used to measure the strain of concrete beams. This study first examined how temperature changes a ected the strain gauge attached to concrete beams. Subsequently, a concrete beam experiencing changes in temperature and load was monitored for six consecutive days. The test results showed that the apparent strain response of the concrete beam was significantly a ected by temperature changes. After adjusting for the temperature e ect, the mechanical strain generated by a load could be obtained. However, temperature-induced drift was still observed in the mechanical strain response. Based on the assumption that temperature changes are slow and gradual, and mechanical strain changes are momentary, an adjacent data subtraction method can be used to eliminate the temperature-induced drift present in the mechanical strain data. The subtraction results show that the mechanical strain generated by a load was accurately obtained. The proposed data-processing method could also be used to find the residual strain of the nonelastic response of a beam subjected to substantial short-term forces. Keywords: strain measurement; temperature effect; mechanical strain; electrical resistance strain gauge 1. Introduction In recent years, structural health monitoring (SHM) has been a popular topic. Structural health monitoring is the installation of various types of sensors (such as accelerometers, tiltmeters, displacement meters, strain gauges, and thermometers) in structures for monitoring structural responses to external stimuli [1–4]. The measured structural response can be used to detect the structural damage or deterioration through the analysis of structural system characteristics, and, thus, the purpose of maintaining the structural safety of the structure, such as a bridge, can be achieved. The SHM system generally includes sensors, data acquisition systems, monitoring centers, and system identification technology [5,6]. In SHM, a large number of sensors are installed and distributed across large areas of a structure. In the past, limited by the large size and high cost of commercially available analog-to-digital converters, the analog-to-digital conversion was often integrated into a multi-channel data logger for execution, causing the need to install multiple independent cables for connecting sensors with the data logger; this formed the traditional and commonly seen centralized data acquisition system. The centralized system has many shortcomings, including the need for a large number of cables, signal attenuation and interference, and diculty in expansion and adjustment of the system [7,8]. In contrast, a distributed system completes the digitization work at the sensor ’s end so as to enable the development of a wireless sensor system. Wireless sensors, owing to their easy installation, low maintenance cost, and flexible Appl. Sci. 2019, 9, 1662; doi:10.3390/app9081662 www.mdpi.com/journal/applsci Appl. Sci. 2019, 9, 1662 2 of 13 deployment, are highly suitable for use in the SHM of bridges. Thus, monitoring systems that are based on wireless sensor networks (WSNs) have become mainstream [9,10]. Strain is the most sensitive physical quantity of the mechanical behavior of concrete beams. External environmental changes (external force, support conditions, and temperature changes) or beam deterioration and damage (cracks, fire, and prestress loss) tend to be clearly reflected on the strain of the concrete beam; therefore, strain measurement should be the first choice for SHM. In the use of electric resistance strain (ERS) gauges on bridge structures, the measured apparent strain includes strain induced by temperature changes and mechanical strain. Theoretically, if the temperature-change-induced strain can be eliminated from the apparent strain, then the mechanical strain required for structural analysis can be obtained. However, because the ERS gauge is a ected by long-term temperature changes, a drift phenomenon is present in the measured strain, causing the signal analysis to become more complex. The temperature-induced drift phenomenon is attributed to a nonlinear relationship between the ambient temperature and the measured strain as illustrated in Figure 1 even in the absence of external force. In addition to ERS gauges, vibration wire (VW) and fiber Bragg grating (FBG) sensors also su er from strain drift caused by temperature changes [11–18]. A technique based on the use of a dummy gauge can eliminate the thermal e ect provided that the dummy gauge is attached on an additional material component that undergoes the same thermal variations as the active gauge but is free from mechanical strain. However, this method is practically dicult for a heterogeneous material, such as concrete. Figure 1. The ambient temperature and measured strain relationship. To deal with a temperature e ect on strain measurement, statistical analysis, especially linear regression, has been widely adopted to find the relationship between the ambient temperature and the measured strain [14,15,17,18]. The statistical approaches cannot remove the temperature-induced strain drift, so only qualitative analysis or trend interpretation of the experimental results can be performed. Kulprapha and Warnitchai [12] presented a study showing good agreement between the measured and the predicted strains by resetting the measured strains to zero every day to avoid the accumulated errors caused by the temperature drift. Based on the data recorded by the resistance strain gauge, this study proposed a simple data-processing method to eliminate temperature-induced drift. The advancement of the study is to provide an easy but e ective way to quantitatively determine the mechanical strain. Wireless ERS gauges were adopted in the study. The research performed tests to study how temperature changes a ected the electrical resistance responses of strain gauges attached to steel and concrete specimens without restraint to obtain the temperature-resistance e ect of the gauges. Then, strain monitoring tests for steel beam and concrete beams were conducted for a number of consecutive days, during which diurnal and nocturnal temperature changes and load changes were experienced. Using the proposed innovative strain data analysis method, temperature e ects were eliminated to obtain the mechanical strain generated by load changes. Finally, the feasibility of using the proposed strain data analysis method to monitor the residual strain generated by a huge load within a short time was examined. Appl. Sci. 2019, 9, 1662 3 of 13 2. The Temperature-Resistance E ect of the Strain Gauge This section examines the e ects of temperature changes on the data measured by the strain gauge attached to the object to be tested. When the test object was not given any constraints, temperature changes would cause the object to generate free thermal expansion and contraction strains (" ) that would be detected by the strain gauge. However, the electrical resistance in the gauge would also change due to temperature changes, and this change would generate unwanted strain (" ) in the measurement. Therefore, when an object without constraints is subjected to temperature changes, the measured temperature strain (" ) can be expressed using the following equation: " = " + " = DT + DT = ( + )DT = DT (1) T u where is the thermal expansion coecient of the object; is the temperature-resistance e ect of the strain gauge; and is the combined temperature e ect coecient ( = + ). Mechanical strain monitoring for steel beams and concrete beams was the study subject of this paper. There was a need to perform separate tests to obtain the combined temperature e ect coecients ( ) for the strain gauge attached to steel and the strain gauge attached to concrete. First, a strain gauge (model number: FLA-10, Tokyo Sokki Kenkyujo Co., Ltd. (TML), Tokyo, Japan, length: 10 mm) was axed on the steel beam, and the steel beam was placed in a temperature-controlled box as illustrated in Figure 2a. During the experiment, a sample was obtained per minute and the temperature underwent changes from 20 to 52 C. Figure 2b shows the relationship of the strain changes and temperature changes within the temperature-controlled box in the experiment; through linear regression, the slope of the regression equation was obtained to be approximately 5.45, meaning that, under unit temperature changes, the combined temperature e ect coecient ( ) of the FLA-10 mm strain gauge axed to the steel beam was 5.45 "/ C. Figure 2. The combined temperature e ect coecient value test of a strain gauge (FLA-10) attached to the steel beam: (a) temperature-controlled box test; (b) strain change and temperature change relationship. Next, this study measured the combined temperature e ect coecient ( ) of the strain gauge (PFL-20) attached to the concrete beam. Because the size of the concrete specimen was relatively large, the temperature change test was conducted outdoors as illustrated in Figure 3a. During the test, a box was used to shield the specimen from direct sunlight. Figure 3b depicts the relationship of the strain changes and temperature changes. Through linear regression analysis, the slope of the regression equation was obtained as approximately 20.17, meaning that, under unit temperature change, the combined temperature e ect coecient ( ) of the strain gauge (PFL-20 mm) attached to the concrete specimen was 20.17 "/ C. Appl. Sci. 2019, 9, 1662 4 of 13 Figure 3. The combined temperature e ect coecient value test of a strain gauge (PFL-20mm) attached to the concrete beam: (a) specimen photograph; (b) test results . To verify the test results of the combined temperature e ect coecient ( ) of the aforementioned resistance strain gauge, the study used a glass ceramic plate manufactured by Zerodur, Germany with an extremely small thermal expansion coecient of 2  10 / C as the base material for the test; the size of the glass ceramic was 150  150  5 mm. For the test, a variety of resistance strain gauge models were axed on the glass ceramic as shown in Figure 4 and the glass ceramic was placed in a temperature-controlled box. The temperature-resistance e ect coecient ( ) of the strain gauge was obtained under the conditions that the base material exhibited no thermal expansion or contraction. Figure 4. Strain gauges attached to a glass ceramic plate with a very small thermal expansion coecient. During the test, the glass ceramic with di erent resistance strain gauges was placed in a temperature-controlled box, and one sample was obtained per minute. The temperature changed from 5 to 55 C over the course of 168 hours (7 days) as shown in Figure 5a. Figure 5b shows the strain change and temperature change relationship diagram of the PFL-20 mm strain gauge. Through linear regression analysis, the slope of the regression equation was obtained as 8.58, meaning that the temperature coecient of resistance ( ) of the PFL-20 mm strain gauge was 8.58 "/ C. Appl. Sci. 2019, 9, 1662 5 of 13 Figure 5. The temperature-resistance e ect of the strain gauge (PFL-20 mm) attached to the Zerodur glass ceramic plate: (a) temperature changes; (b) strain change and temperature relationship. The test results on the temperature changes of the PFL-20 mm strain gauge are summarized in Table 1. Column A is a hypothesized concrete thermal expansion coecient ( ) of 11  10 (11 "/ C). Column B is the temperature-resistance e ect ( ) of the strain gauge axed on the glass ceramic. Using Equation (1), the expected combined temperature e ect coecient was obtained as = + and is listed in Column C of Table 1. The experimental combined temperature e ect coecients obtained from the tests are listed in Column D. A comparison of Column C with Column D indicates that, for the PFL-20mm strain gauge, the di erence between the combined temperature e ect coecient and the expected value was 2.9%, as shown in the last column of Table 1. Table 1. Test results for the temperature-resistance e ect of the strain gauge attached to concrete. A B C = A + B D Expected Experimental Di erence between Gauge model No. 6  6  6  6 (10 / C) (10 / C) (10 / C) (10 / C) C and D PFL-20 mm 11 8.58 19.58 20.17 2.9% PFL-30 mm 11 7.66 18.66 18.89 1.2% PL-90 mm 11 7.81 18.81 19.65 4.5% The aforementioned test was repeated on strain gauges of di erent lengths axed to concrete, and the results are summarized in Table 1. The last column indicates that the di erences between the combined temperature e ect coecient ( ) and the expected value of the various strain gauges were less than 5%. The test results were acceptable, considering the heterogeneity of concrete materials. 3. Strain Monitoring Tests for Beams 3.1. Strain Monitoring Test for a Steel Beam As shown in Figure 6, the study first used a simply supported steel beam for the mechanical strain measurement test. The steel beam’s cross-section dimensions were 16 mm wide and 2 mm thick; the distance between the two load points was 340 mm; and the distance between the two support points was 480 mm. Two FLA-10 mm strain gauges were attached to the top and bottom at the midpoint of the steel beam, respectively, and a thermometer was installed on the steel beam. During the test, the specimen was kept indoors for two days and the load was changed at di erent times. The test procedure was: add a load of 100 g, then add another load of 100 g, then remove a load of 100 g, then remove a load of 100 g. The strain and temperature data were recorded once per minute. Appl. Sci. 2019, 9, 1662 6 of 13 Figure 6. Schematic of the steel beam test. Figure 7a,b show the recorded apparent strain and temperature responses. The apparent strain response in Figure 7a clearly indicated significant changes in strain response at the times of loading (position indicated by solid arrow) as well as unloading (position indicated by dotted arrow). Under the loading condition, the bending moment caused negative strain (compression) and positive strain (tension) on the top and bottom strain gauges, respectively; the opposite was observed under the unloading condition. Theoretically, when a load is not augmented or reduced, no strain change should exist. However, Figure 7a showed that a nonlinear apparent strain response was present during the load application intervals, and the undulations were consistent with the temperature trend in Figure 7b. This phenomenon indicated that temperature changes a ected the apparent strain recorded during the test. Figure 7. The steel beam test: (a) strain gauge response; (b) temperature changes. To obtain the mechanical strain (" ), the temperature strain (" ) induced by temperature changes m T (DT) must be subtracted from the recorded apparent strain ("), that is, " = " DT. According to the previous test, the combined temperature e ect coecient ( ) of the FLA-10 mm strain gauge axed to the steel beam was 5.45 "/ C (refer to Figure 1), so the apparent strain (") in Figure 6a and the temperature changes (DT) in Figure 6b can be combined to obtain the mechanical strain response of the steel beam, as shown in Figure 8a. After temperature correction, the mechanical strain in Figure 8a showed that, when the system had no load addition or removal, the strain response did not fluctuate with the temperature changes but resembled an almost flat straight line, and after removal of all load (after 30 h), the mechanical strain also returned to close to the 0 position. This shows that the temperature-induced drift was not significant in such a case. Figure 8. The steel beam test: (a) mechanical strain; (b) change in mechanical strain per unit time. Appl. Sci. 2019, 9, 1662 7 of 13 Although the temperature-induced drift in this test was not significant, the test results of a concrete beam to be discussed in the subsequent section showed significant temperature drift. A data-processing method was thus proposed to eliminate temperature drift interference. The proposed method was based on the assumption that temperature changes are slow and mechanical strain changes are abrupt; therefore, an adjacent data subtraction method was applied to the time-history data of mechanical strain response to obtain the relative changes in mechanical strain at adjacent times; thus, the e ects of temperature drift could be significantly reduced. The adjacent data subtraction means that the current data were subtracted by their preceding data. Figure 8b displays the change in mechanical strain per unit time obtained by performing adjacent data subtraction of Figure 8a. In Figure 8b, only the four time points of load application and removal showed significant mechanical strain changes. The relative changes in mechanical strain at all other time points were within 2 ". Under the assumption that the elastic modulus of the steel beam was 210 GPa, the theoretical strain at the top and bottom of the steel beam subjected to a load of 100 g was calculated to be approximately 15.62 ". Comparing the positive or negative strain obtained from the four load applications in Figure 8b with the obtained theoretical strain showed that only one strain data point, 14.38 ", had a di erence of 1.24 "; the di erences of the other seven data points were less than 1 ". It is worth mentioning that the maximum absolute error (1.24 ") is quite close to the strain accuracy (1.0 ") provided by the measuring instrument itself. The test results showed that the proposed data analysis method could easily and accurately obtain the mechanical strain generated by the load. 3.2. Strain Monitoring Test for a Concrete Beam This subsection used a small concrete beam as the specimen for the strain monitoring test. The beam section measured 57 mm wide and 30 mm thick. The support length was 450 mm, and a welded wire mesh was placed at a distance of 5 mm from the bottom. Figure 9 is the schematic of the concrete beam test. During the test, a PFL-20 mm strain gauge was attached to the top and bottom of the midpoint of the beam, and two thermometers were positioned at the top and bottom of the beam midpoint, respectively. Figure 9. Schematic of the concrete beam test. The test specimen was kept indoors for approximately 6 days. During the test, a load was applied or removed at di erent time points; the procedure was: add load 5 kgf, add load 5 kgf, remove load 5 kgf, and remove load 5 kgf. The strain and temperature data were recorded once per minute. Figure 10a,b illustrate the recorded apparent strain and temperature responses, respectively. In comparison with the steel beam test results of Figure 7a, the momentary mechanical strain response generated by load application or removal was dicult to identify from the apparent strain response recorded by the concrete beam test in Figure 10a; the entire apparent strain response was almost consistent with the temperature variation trend in Figure 10b. This phenomenon indicated that temperature changes dominated the entire apparent strain response and masked the mechanical strain response; therefore, the mechanical strain generated by load application or removal could not be determined. Figure 10b indicates that the temperature curves of the top and bottom of the beam are almost overlapping and Appl. Sci. 2019, 9, 1662 8 of 13 the largest di erence was only 0.1 C. Thus, this small concrete beam could be considered to have a uniform temperature distribution. Figure 10. The concrete beam test: (a) strain recorded at the top and bottom of the beam midpoint; (b) temperature at the top and bottom of the beam midpoint. Because it was not easy to observe the mechanical strain generated by load application or removal from the apparent strain data in Figure 10a, it was necessary to consider the e ects of temperature changes. To obtain the mechanical strain (" ), the temperature strain (" ) induced by temperature m T changes (DT) must be eliminated from the recorded apparent strain ("), that is, " = " DT. According to previous testing, the combined temperature e ect coecient ( ) of the PFL-20 mm strain gauge attached to the concrete was 20.17 "/ C (refer to Figure 3). Hence, the apparent strain in Figure 10a and the temperature variation in Figure 10b could be combined to obtain the mechanical strain time-history response of the concrete beam, as shown in Figure 11a. After temperature correction, an abrupt mechanical strain change generated by load application or removal could already be slightly discerned from the mechanical strain time-history response in Figure 11a, as indicated by the arrow in the diagram. However, because the temperature drift was considerably significant, the mechanical strain response did not return to the 0 position even after the load had been completely removed. This phenomenon di ered greatly from the steel beam test results in Figure 8a. Figure 11b is the mechanical strain change per unit time obtained by performing the adjacent data subtraction of Figure 11a. The adjacent data subtraction means that the current data were subtracted by their preceding data. In Figure 11b, only the four time points of load application and removal showed significant mechanical strain di erences; the mechanical strain di erences at all other time points were mostly within 3 ". It is notable that, in Figure 11b, an unexpected noise occurred in the mechanical strain di erence because of a minor temperature fluctuation near the 40 h time point of the x-axis (as shown in Figure 12). This type of noise can be ignored by observing the temperature curve; it would not a ect the identification of the mechanical strain generated by load application or removal. Figure 11. Cont. Appl. Sci. 2019, 9, 1662 9 of 13 Figure 11. The concrete beam test: (a) mechanical strain; (b) change in mechanical strain per unit time. Figure 12. Minor temperature fluctuations near the 40-h time point. To verify the accuracy of the mechanical strain obtained in the aforementioned test, a load of 5 kgf was applied to the concrete beam used in the test within a short time (to prevent temperature change e ects) and the strain changes at the top and bottom of the beam were recorded. The test was repeated thrice, and the obtained results are summarized in Table 2. The averages of the strain at the top and bottom of the beam obtained through the three load tests were 13.90 " and 12.23 ", respectively. The average strain obtained from the three load tests can be treated as the baseline value for performing a di erence comparison of the mechanical strain obtained by the study using the temperature e ect elimination method. The comparison results are listed in Table 3. In Table 3, it can be observed that the largest di erence between the two was only 1.3 ", indicating that the test results were favorable. The test results showed that the apparent strain was significantly a ected by the considerable temperature drift of the heterogeneous concrete beam; through the proposed data analysis method, the load-generated mechanical strain was obtained accurately. Table 2. The short-term load addition test for measuring the strain at the top and bottom of the beam. Load Addition 5 kg Strain at the Top of the Beam (") Strain at the Bottom of the Beam (") 1st short-term load addition test 13.52 12.76 2nd short-term load addition test 14.15 11.76 3rd short-term load addition test 14.02 12.18 Average of the short-term load 13.90 12.23 application tests Appl. Sci. 2019, 9, 1662 10 of 13 Table 3. Test error for mechanical strain with temperature e ects eliminated. Add Load Add Load Remove Remove Load Load Changes 5 kgf 5 kgf Load 5 kgf 5 kgf Strain obtained in short-term load 13.90 addition test (") Beam top Mechanical strain with temperature 12.72 13.70 13.44 13.00 e ect elimination (") Di erence (") 1.18 0.20 0.46 0.90 Strain obtained in short-term load 12.23 addition test (") Beam bottom Mechanical strain with temperature 10.93 11.47 12.21 10.96 e ect elimination (") Di erence (") 1.30 0.76 0.02 1.27 4. Residual Strain Monitoring Test for Nonelastic Response The previous section proves that the proposed data-processing method could e ectively eliminate temperature e ects and obtain the accurate mechanical strain. This section examined the feasibility of using this data-processing method to monitor the residual strain of concrete beams when the beams had the nonelastic response caused by a considerable load. If feasible, this technique could be used to assess the presence of residual strain after a bridge structure had been subjected to seismic forces, and could be a technique for easy and e ective assessment of damage to bridge structures. The dimensions of the beam and the load configuration used for the test were the same as in Figure 9 in Section 3.2. A steel plate with a thickness of 1 mm was glued to the top of the concrete beam to avoid brittle failure of the beam. The test period was 44 hours, and three time points were selected for short-term load application and removal. To enable the test specimen to generate nonelastic responses, a relatively large load (approximately 110 kgf) was given; residual strain occurred after load removal. Figure 13 shows the time-history response of the apparent strain at the beam bottom obtained by the test; a relatively large strain response (marked by the red dotted-line rectangle) generated by the three short-term load applications can be observed in the figure. Generally, in static monitoring of bridges, data are mostly retrieved at 10-minute or longer intervals. Therefore, a short-term seismic force response could not be recorded in a static apparent strain response. To simulate this type of scenario, the study eliminated the short-term large apparent strain response marked by the three red dotted-line rectangles in Figure 13. Figure 13. The apparent strain response of the nonelastic response test for the concrete beam. Figure 14a shows the apparent strain time-history curve obtained after deleting the strain data caused by the short-term loads, and Figure 14b shows the temperature change curve recorded during the test. Figure 13c shows the mechanical strain (" ) obtained by eliminating the temperature strain (" ) induced by the temperature change (DT) in Figure 14b from the apparent strain (") of Figure 14a. The mechanical strain in Figure 14c was significantly a ected by temperature drift, and was practically impossible to analyze. Using the same processing method as used in the previous section, the adjacent Appl. Sci. 2019, 9, 1662 11 of 13 data subtraction method was applied to the mechanical strain data in Figure 14c to obtain the change in mechanical strain per unit time, as illustrated in Figure 14d. Figure 14d clearly indicates that residual strains of 3.54, 5.78, and 4.91 " occurred at the three short-term load application time points. Figure 14. The concrete beam nonelastic response test: (a) strain response after deleting short-term loads; (b) beam bottom temperature changes; (c) mechanical strain; (d) change in mechanical strain per unit time. The preliminary test in this section already proved the proposed concept: given that temperature changes are slow and mechanical strain changes are momentary, application of adjacent data subtraction to mechanical strain data can eliminate the e ects of temperature drift. In addition to accurately analyzing the mechanical strains of load application and removal, this type of concept could also be used to analyze the residual strain of the nonelastic response of the concrete beam generated by the application of substantial short-term loads. 5. Conclusions This study used a wireless resistance strain gauge measurement system to measure the strain response of beams. The research performed long-term load tests for a steel beam and a concrete beam, and nonelastic response tests for a concrete beam, to examine the e ects of temperature changes on the strain responses obtained by the tests. Based on the test results, conclusions were obtained as follows: 1. When the load-generated mechanical response was smaller than the thermal strain response induced by temperature changes, the measured apparent strain response would be influenced by temperature changes, and the load-generated mechanical strain could not be obtained through analyzing apparent strain. 2. Mechanical strain could be obtained by eliminating the temperature-induced strain from the apparent strain. The mechanical strain of abrupt changes generated by load application and removal could be observed in the mechanical strain time-history curve. However, because of the presence of temperature-induced drift, the mechanical strain response could not return to the Appl. Sci. 2019, 9, 1662 12 of 13 0 position even after the removal of all loads. Moreover, as time passed, the temperature drift e ect caused the mechanical strain to move further away from 0. This temperature drift made analyzing mechanical strain dicult. 3. Given that temperature changes are slow and mechanical strain changes are momentary, this study proposed a simple data-processing method, namely, to use adjacent data subtraction on the mechanical strain time-history curve to eliminate the temperature drift e ect. The obtained mechanical strain change per unit time can be used to accurately determine the mechanical strain generated by load application and removal. In addition to precise analysis of load-generated mechanical strain, the adjacent data subtraction of mechanical strain time-history data could also be used to analyze the residual strain of the nonelastic response of a concrete beam subjected to substantial short-term loads. Author Contributions: Conceptualization and methodology, Y.L.; measurements, Y.-W.C.; development sensors, Y.-T.L.; data analysis, Y.L., Y.-T.L. and Y.-W.C.; writing—original draft preparation, Y.L., Y.-T.L. and Y.-W.C. Funding: This work was sponsored by the Ministry of Science and Technology, Taiwan, ROC under Grant No. MOST 106-2221-E-005 -036 -MY3. Conflicts of Interest: The authors declare no conflict of interest. References 1. Chang, P.C.; Flatau, A.; Liu, S.C. Review Paper: Health Monitoring of Civil Infrastructure. Acoust. Speech Signal Process. Newslett. IEEE 2003, 2, 257–267. [CrossRef] 2. Farrar, C.R.; Worden, K. An introduction to structural health monitoring. Philos. Trans. A Math. Phys. Eng. Sci. 2007, 365, 303–315. [CrossRef] [PubMed] 3. Xia, Y.; Chen, B.; Weng, S.; Ni, Y.Q.; Xu, Y.L. Temperature e ect on vibration properties of civil structures: A literature review and case studies. JCSHM 2012, 2, 29–46. [CrossRef] 4. Kromanis, R. Structural Performance Evaluation of Bridges: Characterizing and Integrating Thermal Response. Ph.D. Thesis, University of Exeter, Exeter, UK, January 2015. 5. Li, H.N.; Ren, L.; Jia, Z.G.; Yi, T.H.; Li, D.S. State-of-the-art in structural health monitoring of large and complex civil infrastructures. JCSHM 2016, 6, 3–16. [CrossRef] 6. Chen, Z.; Zhou, X.; Wang, X.; Dong, L.; Qian, Y. Deployment of a Smart Structural Health Monitoring System for Long-Span Arch Bridges: A Review and a Case Study. Sensors 2017, 17, 2151. [CrossRef] [PubMed] 7. Zhou, G.D.; Yi, T.H. Recent developments on wireless sensor networks technology for bridge health monitoring. Math. Probl. Eng. 2013, 3, 1–33. [CrossRef] 8. Chae, M.J.; Yoo, H.S.; Kim, J.Y.; Cho, M.Y. Development of a wireless sensor network system for suspension bridge health monitoring. Automat. Constr. 2012, 21, 237–252. [CrossRef] 9. Lynch, J.P.; Loh, K.J. A Summary Review of Wireless Sensors and Sensor Networks for Structural Health Monitoring. Shock Vib. Digest 2006, 38, 91–128. [CrossRef] 10. Liu, C.; Teng, J.; Wu, N. A Wireless Strain Sensor Network for Structural Health Monitoring. Shock Vib. 2015, 2015, 1–13. [CrossRef] 11. Papadopoulos, K.; Morfiadakis, E.; Philippidis, T.P.; Lekou, D.J. Assessment of the strain gauge technique for measurement of wind turbine blade loads. Wind Energy 2000, 3, 35–65. [CrossRef] 12. Kulprapha, N.; Warnitchai, P. Structural health monitoring of continuous prestressed concrete bridges using ambient thermal responses. Eng. Struct. 2012, 40, 20–38. [CrossRef] 13. Ge, Y.; Elshafie, M.Z.E.B.; Dirar, S.; Middleton, C.R. The response of embedded strain sensors in concrete beams subjected to thermal loading. Constr. Build. Mater. 2014, 70, 279–290. [CrossRef] 14. Prakash, G.; Sadhu, A.; Narasimhan, S.; Brehe, J.M. Initial service life data towards structural health monitoring of a concrete arch dam. Struct. Contr. Health Monit. 2018, 25, 1–19. [CrossRef] 15. Newell, S.; Goggins, J. Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors. IJCSM 2018, 12, 66. [CrossRef] Appl. Sci. 2019, 9, 1662 13 of 13 16. Küsel, F.; Kearsley, E.; Butler, L.J.; Skorpen, S.A.; Elshafie, M.Z.E.B. Measured temperature e ects during the construction of a prestressed precast concrete bridge beam. In Proceedings of the International Conference on Concrete Repair, Rehabilitation and Retrofitting, Cape Town, South Africa, 19–21 November 2018. 17. Kaloop, M.R.; Hu, J.W.; Elbeltagi, E. Time-Series and Frequency-Spectrum Correlation Analysis of Bridge Performance Based on a Real-Time Strain Monitoring System. ISPRS Int. J. Geo. Inf. 2016, 5, 61. [CrossRef] 18. Chen, C.; Wang, Z.; Wang, Y.; Wang, T.; Luo, Z. Reliability Assessment for PSC Box-Girder Bridges Based on SHM Strain Measurements. J. Sens. 2017, 2017, 1–13. [CrossRef] © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Applied Sciences Multidisciplinary Digital Publishing Institute

An Investigation of the Temperature-Drift Effect on Strain Measurement of Concrete Beams

Applied Sciences , Volume 9 (8) – Apr 22, 2019

Loading next page...
 
/lp/multidisciplinary-digital-publishing-institute/an-investigation-of-the-temperature-drift-effect-on-strain-measurement-WwBJprCKyl

References (19)

Publisher
Multidisciplinary Digital Publishing Institute
Copyright
© 1996-2019 MDPI (Basel, Switzerland) unless otherwise stated
ISSN
2076-3417
DOI
10.3390/app9081662
Publisher site
See Article on Publisher Site

Abstract

applied sciences Article An Investigation of the Temperature-Drift E ect on Strain Measurement of Concrete Beams Yiching Lin * , Yu-Ting Liu and Yu-Wen Chang Department of Civil Engineering, National Chung Hsing University, Taichung 402, Taiwan; ruliner1107@gmail.com (Y.-T.L.); winnie83216@gmail.com (Y.-W.C.) * Correspondence: yiching@nchu.edu.tw Received: 8 March 2019; Accepted: 15 April 2019; Published: 22 April 2019 Abstract: This study investigates the temperature-drift e ect on strain measurement of concrete beams and proposes a method for determination of the mechanical strain of stressed concrete beams. In the study, wireless electrical resistance strain gauges were used to measure the strain of concrete beams. This study first examined how temperature changes a ected the strain gauge attached to concrete beams. Subsequently, a concrete beam experiencing changes in temperature and load was monitored for six consecutive days. The test results showed that the apparent strain response of the concrete beam was significantly a ected by temperature changes. After adjusting for the temperature e ect, the mechanical strain generated by a load could be obtained. However, temperature-induced drift was still observed in the mechanical strain response. Based on the assumption that temperature changes are slow and gradual, and mechanical strain changes are momentary, an adjacent data subtraction method can be used to eliminate the temperature-induced drift present in the mechanical strain data. The subtraction results show that the mechanical strain generated by a load was accurately obtained. The proposed data-processing method could also be used to find the residual strain of the nonelastic response of a beam subjected to substantial short-term forces. Keywords: strain measurement; temperature effect; mechanical strain; electrical resistance strain gauge 1. Introduction In recent years, structural health monitoring (SHM) has been a popular topic. Structural health monitoring is the installation of various types of sensors (such as accelerometers, tiltmeters, displacement meters, strain gauges, and thermometers) in structures for monitoring structural responses to external stimuli [1–4]. The measured structural response can be used to detect the structural damage or deterioration through the analysis of structural system characteristics, and, thus, the purpose of maintaining the structural safety of the structure, such as a bridge, can be achieved. The SHM system generally includes sensors, data acquisition systems, monitoring centers, and system identification technology [5,6]. In SHM, a large number of sensors are installed and distributed across large areas of a structure. In the past, limited by the large size and high cost of commercially available analog-to-digital converters, the analog-to-digital conversion was often integrated into a multi-channel data logger for execution, causing the need to install multiple independent cables for connecting sensors with the data logger; this formed the traditional and commonly seen centralized data acquisition system. The centralized system has many shortcomings, including the need for a large number of cables, signal attenuation and interference, and diculty in expansion and adjustment of the system [7,8]. In contrast, a distributed system completes the digitization work at the sensor ’s end so as to enable the development of a wireless sensor system. Wireless sensors, owing to their easy installation, low maintenance cost, and flexible Appl. Sci. 2019, 9, 1662; doi:10.3390/app9081662 www.mdpi.com/journal/applsci Appl. Sci. 2019, 9, 1662 2 of 13 deployment, are highly suitable for use in the SHM of bridges. Thus, monitoring systems that are based on wireless sensor networks (WSNs) have become mainstream [9,10]. Strain is the most sensitive physical quantity of the mechanical behavior of concrete beams. External environmental changes (external force, support conditions, and temperature changes) or beam deterioration and damage (cracks, fire, and prestress loss) tend to be clearly reflected on the strain of the concrete beam; therefore, strain measurement should be the first choice for SHM. In the use of electric resistance strain (ERS) gauges on bridge structures, the measured apparent strain includes strain induced by temperature changes and mechanical strain. Theoretically, if the temperature-change-induced strain can be eliminated from the apparent strain, then the mechanical strain required for structural analysis can be obtained. However, because the ERS gauge is a ected by long-term temperature changes, a drift phenomenon is present in the measured strain, causing the signal analysis to become more complex. The temperature-induced drift phenomenon is attributed to a nonlinear relationship between the ambient temperature and the measured strain as illustrated in Figure 1 even in the absence of external force. In addition to ERS gauges, vibration wire (VW) and fiber Bragg grating (FBG) sensors also su er from strain drift caused by temperature changes [11–18]. A technique based on the use of a dummy gauge can eliminate the thermal e ect provided that the dummy gauge is attached on an additional material component that undergoes the same thermal variations as the active gauge but is free from mechanical strain. However, this method is practically dicult for a heterogeneous material, such as concrete. Figure 1. The ambient temperature and measured strain relationship. To deal with a temperature e ect on strain measurement, statistical analysis, especially linear regression, has been widely adopted to find the relationship between the ambient temperature and the measured strain [14,15,17,18]. The statistical approaches cannot remove the temperature-induced strain drift, so only qualitative analysis or trend interpretation of the experimental results can be performed. Kulprapha and Warnitchai [12] presented a study showing good agreement between the measured and the predicted strains by resetting the measured strains to zero every day to avoid the accumulated errors caused by the temperature drift. Based on the data recorded by the resistance strain gauge, this study proposed a simple data-processing method to eliminate temperature-induced drift. The advancement of the study is to provide an easy but e ective way to quantitatively determine the mechanical strain. Wireless ERS gauges were adopted in the study. The research performed tests to study how temperature changes a ected the electrical resistance responses of strain gauges attached to steel and concrete specimens without restraint to obtain the temperature-resistance e ect of the gauges. Then, strain monitoring tests for steel beam and concrete beams were conducted for a number of consecutive days, during which diurnal and nocturnal temperature changes and load changes were experienced. Using the proposed innovative strain data analysis method, temperature e ects were eliminated to obtain the mechanical strain generated by load changes. Finally, the feasibility of using the proposed strain data analysis method to monitor the residual strain generated by a huge load within a short time was examined. Appl. Sci. 2019, 9, 1662 3 of 13 2. The Temperature-Resistance E ect of the Strain Gauge This section examines the e ects of temperature changes on the data measured by the strain gauge attached to the object to be tested. When the test object was not given any constraints, temperature changes would cause the object to generate free thermal expansion and contraction strains (" ) that would be detected by the strain gauge. However, the electrical resistance in the gauge would also change due to temperature changes, and this change would generate unwanted strain (" ) in the measurement. Therefore, when an object without constraints is subjected to temperature changes, the measured temperature strain (" ) can be expressed using the following equation: " = " + " = DT + DT = ( + )DT = DT (1) T u where is the thermal expansion coecient of the object; is the temperature-resistance e ect of the strain gauge; and is the combined temperature e ect coecient ( = + ). Mechanical strain monitoring for steel beams and concrete beams was the study subject of this paper. There was a need to perform separate tests to obtain the combined temperature e ect coecients ( ) for the strain gauge attached to steel and the strain gauge attached to concrete. First, a strain gauge (model number: FLA-10, Tokyo Sokki Kenkyujo Co., Ltd. (TML), Tokyo, Japan, length: 10 mm) was axed on the steel beam, and the steel beam was placed in a temperature-controlled box as illustrated in Figure 2a. During the experiment, a sample was obtained per minute and the temperature underwent changes from 20 to 52 C. Figure 2b shows the relationship of the strain changes and temperature changes within the temperature-controlled box in the experiment; through linear regression, the slope of the regression equation was obtained to be approximately 5.45, meaning that, under unit temperature changes, the combined temperature e ect coecient ( ) of the FLA-10 mm strain gauge axed to the steel beam was 5.45 "/ C. Figure 2. The combined temperature e ect coecient value test of a strain gauge (FLA-10) attached to the steel beam: (a) temperature-controlled box test; (b) strain change and temperature change relationship. Next, this study measured the combined temperature e ect coecient ( ) of the strain gauge (PFL-20) attached to the concrete beam. Because the size of the concrete specimen was relatively large, the temperature change test was conducted outdoors as illustrated in Figure 3a. During the test, a box was used to shield the specimen from direct sunlight. Figure 3b depicts the relationship of the strain changes and temperature changes. Through linear regression analysis, the slope of the regression equation was obtained as approximately 20.17, meaning that, under unit temperature change, the combined temperature e ect coecient ( ) of the strain gauge (PFL-20 mm) attached to the concrete specimen was 20.17 "/ C. Appl. Sci. 2019, 9, 1662 4 of 13 Figure 3. The combined temperature e ect coecient value test of a strain gauge (PFL-20mm) attached to the concrete beam: (a) specimen photograph; (b) test results . To verify the test results of the combined temperature e ect coecient ( ) of the aforementioned resistance strain gauge, the study used a glass ceramic plate manufactured by Zerodur, Germany with an extremely small thermal expansion coecient of 2  10 / C as the base material for the test; the size of the glass ceramic was 150  150  5 mm. For the test, a variety of resistance strain gauge models were axed on the glass ceramic as shown in Figure 4 and the glass ceramic was placed in a temperature-controlled box. The temperature-resistance e ect coecient ( ) of the strain gauge was obtained under the conditions that the base material exhibited no thermal expansion or contraction. Figure 4. Strain gauges attached to a glass ceramic plate with a very small thermal expansion coecient. During the test, the glass ceramic with di erent resistance strain gauges was placed in a temperature-controlled box, and one sample was obtained per minute. The temperature changed from 5 to 55 C over the course of 168 hours (7 days) as shown in Figure 5a. Figure 5b shows the strain change and temperature change relationship diagram of the PFL-20 mm strain gauge. Through linear regression analysis, the slope of the regression equation was obtained as 8.58, meaning that the temperature coecient of resistance ( ) of the PFL-20 mm strain gauge was 8.58 "/ C. Appl. Sci. 2019, 9, 1662 5 of 13 Figure 5. The temperature-resistance e ect of the strain gauge (PFL-20 mm) attached to the Zerodur glass ceramic plate: (a) temperature changes; (b) strain change and temperature relationship. The test results on the temperature changes of the PFL-20 mm strain gauge are summarized in Table 1. Column A is a hypothesized concrete thermal expansion coecient ( ) of 11  10 (11 "/ C). Column B is the temperature-resistance e ect ( ) of the strain gauge axed on the glass ceramic. Using Equation (1), the expected combined temperature e ect coecient was obtained as = + and is listed in Column C of Table 1. The experimental combined temperature e ect coecients obtained from the tests are listed in Column D. A comparison of Column C with Column D indicates that, for the PFL-20mm strain gauge, the di erence between the combined temperature e ect coecient and the expected value was 2.9%, as shown in the last column of Table 1. Table 1. Test results for the temperature-resistance e ect of the strain gauge attached to concrete. A B C = A + B D Expected Experimental Di erence between Gauge model No. 6  6  6  6 (10 / C) (10 / C) (10 / C) (10 / C) C and D PFL-20 mm 11 8.58 19.58 20.17 2.9% PFL-30 mm 11 7.66 18.66 18.89 1.2% PL-90 mm 11 7.81 18.81 19.65 4.5% The aforementioned test was repeated on strain gauges of di erent lengths axed to concrete, and the results are summarized in Table 1. The last column indicates that the di erences between the combined temperature e ect coecient ( ) and the expected value of the various strain gauges were less than 5%. The test results were acceptable, considering the heterogeneity of concrete materials. 3. Strain Monitoring Tests for Beams 3.1. Strain Monitoring Test for a Steel Beam As shown in Figure 6, the study first used a simply supported steel beam for the mechanical strain measurement test. The steel beam’s cross-section dimensions were 16 mm wide and 2 mm thick; the distance between the two load points was 340 mm; and the distance between the two support points was 480 mm. Two FLA-10 mm strain gauges were attached to the top and bottom at the midpoint of the steel beam, respectively, and a thermometer was installed on the steel beam. During the test, the specimen was kept indoors for two days and the load was changed at di erent times. The test procedure was: add a load of 100 g, then add another load of 100 g, then remove a load of 100 g, then remove a load of 100 g. The strain and temperature data were recorded once per minute. Appl. Sci. 2019, 9, 1662 6 of 13 Figure 6. Schematic of the steel beam test. Figure 7a,b show the recorded apparent strain and temperature responses. The apparent strain response in Figure 7a clearly indicated significant changes in strain response at the times of loading (position indicated by solid arrow) as well as unloading (position indicated by dotted arrow). Under the loading condition, the bending moment caused negative strain (compression) and positive strain (tension) on the top and bottom strain gauges, respectively; the opposite was observed under the unloading condition. Theoretically, when a load is not augmented or reduced, no strain change should exist. However, Figure 7a showed that a nonlinear apparent strain response was present during the load application intervals, and the undulations were consistent with the temperature trend in Figure 7b. This phenomenon indicated that temperature changes a ected the apparent strain recorded during the test. Figure 7. The steel beam test: (a) strain gauge response; (b) temperature changes. To obtain the mechanical strain (" ), the temperature strain (" ) induced by temperature changes m T (DT) must be subtracted from the recorded apparent strain ("), that is, " = " DT. According to the previous test, the combined temperature e ect coecient ( ) of the FLA-10 mm strain gauge axed to the steel beam was 5.45 "/ C (refer to Figure 1), so the apparent strain (") in Figure 6a and the temperature changes (DT) in Figure 6b can be combined to obtain the mechanical strain response of the steel beam, as shown in Figure 8a. After temperature correction, the mechanical strain in Figure 8a showed that, when the system had no load addition or removal, the strain response did not fluctuate with the temperature changes but resembled an almost flat straight line, and after removal of all load (after 30 h), the mechanical strain also returned to close to the 0 position. This shows that the temperature-induced drift was not significant in such a case. Figure 8. The steel beam test: (a) mechanical strain; (b) change in mechanical strain per unit time. Appl. Sci. 2019, 9, 1662 7 of 13 Although the temperature-induced drift in this test was not significant, the test results of a concrete beam to be discussed in the subsequent section showed significant temperature drift. A data-processing method was thus proposed to eliminate temperature drift interference. The proposed method was based on the assumption that temperature changes are slow and mechanical strain changes are abrupt; therefore, an adjacent data subtraction method was applied to the time-history data of mechanical strain response to obtain the relative changes in mechanical strain at adjacent times; thus, the e ects of temperature drift could be significantly reduced. The adjacent data subtraction means that the current data were subtracted by their preceding data. Figure 8b displays the change in mechanical strain per unit time obtained by performing adjacent data subtraction of Figure 8a. In Figure 8b, only the four time points of load application and removal showed significant mechanical strain changes. The relative changes in mechanical strain at all other time points were within 2 ". Under the assumption that the elastic modulus of the steel beam was 210 GPa, the theoretical strain at the top and bottom of the steel beam subjected to a load of 100 g was calculated to be approximately 15.62 ". Comparing the positive or negative strain obtained from the four load applications in Figure 8b with the obtained theoretical strain showed that only one strain data point, 14.38 ", had a di erence of 1.24 "; the di erences of the other seven data points were less than 1 ". It is worth mentioning that the maximum absolute error (1.24 ") is quite close to the strain accuracy (1.0 ") provided by the measuring instrument itself. The test results showed that the proposed data analysis method could easily and accurately obtain the mechanical strain generated by the load. 3.2. Strain Monitoring Test for a Concrete Beam This subsection used a small concrete beam as the specimen for the strain monitoring test. The beam section measured 57 mm wide and 30 mm thick. The support length was 450 mm, and a welded wire mesh was placed at a distance of 5 mm from the bottom. Figure 9 is the schematic of the concrete beam test. During the test, a PFL-20 mm strain gauge was attached to the top and bottom of the midpoint of the beam, and two thermometers were positioned at the top and bottom of the beam midpoint, respectively. Figure 9. Schematic of the concrete beam test. The test specimen was kept indoors for approximately 6 days. During the test, a load was applied or removed at di erent time points; the procedure was: add load 5 kgf, add load 5 kgf, remove load 5 kgf, and remove load 5 kgf. The strain and temperature data were recorded once per minute. Figure 10a,b illustrate the recorded apparent strain and temperature responses, respectively. In comparison with the steel beam test results of Figure 7a, the momentary mechanical strain response generated by load application or removal was dicult to identify from the apparent strain response recorded by the concrete beam test in Figure 10a; the entire apparent strain response was almost consistent with the temperature variation trend in Figure 10b. This phenomenon indicated that temperature changes dominated the entire apparent strain response and masked the mechanical strain response; therefore, the mechanical strain generated by load application or removal could not be determined. Figure 10b indicates that the temperature curves of the top and bottom of the beam are almost overlapping and Appl. Sci. 2019, 9, 1662 8 of 13 the largest di erence was only 0.1 C. Thus, this small concrete beam could be considered to have a uniform temperature distribution. Figure 10. The concrete beam test: (a) strain recorded at the top and bottom of the beam midpoint; (b) temperature at the top and bottom of the beam midpoint. Because it was not easy to observe the mechanical strain generated by load application or removal from the apparent strain data in Figure 10a, it was necessary to consider the e ects of temperature changes. To obtain the mechanical strain (" ), the temperature strain (" ) induced by temperature m T changes (DT) must be eliminated from the recorded apparent strain ("), that is, " = " DT. According to previous testing, the combined temperature e ect coecient ( ) of the PFL-20 mm strain gauge attached to the concrete was 20.17 "/ C (refer to Figure 3). Hence, the apparent strain in Figure 10a and the temperature variation in Figure 10b could be combined to obtain the mechanical strain time-history response of the concrete beam, as shown in Figure 11a. After temperature correction, an abrupt mechanical strain change generated by load application or removal could already be slightly discerned from the mechanical strain time-history response in Figure 11a, as indicated by the arrow in the diagram. However, because the temperature drift was considerably significant, the mechanical strain response did not return to the 0 position even after the load had been completely removed. This phenomenon di ered greatly from the steel beam test results in Figure 8a. Figure 11b is the mechanical strain change per unit time obtained by performing the adjacent data subtraction of Figure 11a. The adjacent data subtraction means that the current data were subtracted by their preceding data. In Figure 11b, only the four time points of load application and removal showed significant mechanical strain di erences; the mechanical strain di erences at all other time points were mostly within 3 ". It is notable that, in Figure 11b, an unexpected noise occurred in the mechanical strain di erence because of a minor temperature fluctuation near the 40 h time point of the x-axis (as shown in Figure 12). This type of noise can be ignored by observing the temperature curve; it would not a ect the identification of the mechanical strain generated by load application or removal. Figure 11. Cont. Appl. Sci. 2019, 9, 1662 9 of 13 Figure 11. The concrete beam test: (a) mechanical strain; (b) change in mechanical strain per unit time. Figure 12. Minor temperature fluctuations near the 40-h time point. To verify the accuracy of the mechanical strain obtained in the aforementioned test, a load of 5 kgf was applied to the concrete beam used in the test within a short time (to prevent temperature change e ects) and the strain changes at the top and bottom of the beam were recorded. The test was repeated thrice, and the obtained results are summarized in Table 2. The averages of the strain at the top and bottom of the beam obtained through the three load tests were 13.90 " and 12.23 ", respectively. The average strain obtained from the three load tests can be treated as the baseline value for performing a di erence comparison of the mechanical strain obtained by the study using the temperature e ect elimination method. The comparison results are listed in Table 3. In Table 3, it can be observed that the largest di erence between the two was only 1.3 ", indicating that the test results were favorable. The test results showed that the apparent strain was significantly a ected by the considerable temperature drift of the heterogeneous concrete beam; through the proposed data analysis method, the load-generated mechanical strain was obtained accurately. Table 2. The short-term load addition test for measuring the strain at the top and bottom of the beam. Load Addition 5 kg Strain at the Top of the Beam (") Strain at the Bottom of the Beam (") 1st short-term load addition test 13.52 12.76 2nd short-term load addition test 14.15 11.76 3rd short-term load addition test 14.02 12.18 Average of the short-term load 13.90 12.23 application tests Appl. Sci. 2019, 9, 1662 10 of 13 Table 3. Test error for mechanical strain with temperature e ects eliminated. Add Load Add Load Remove Remove Load Load Changes 5 kgf 5 kgf Load 5 kgf 5 kgf Strain obtained in short-term load 13.90 addition test (") Beam top Mechanical strain with temperature 12.72 13.70 13.44 13.00 e ect elimination (") Di erence (") 1.18 0.20 0.46 0.90 Strain obtained in short-term load 12.23 addition test (") Beam bottom Mechanical strain with temperature 10.93 11.47 12.21 10.96 e ect elimination (") Di erence (") 1.30 0.76 0.02 1.27 4. Residual Strain Monitoring Test for Nonelastic Response The previous section proves that the proposed data-processing method could e ectively eliminate temperature e ects and obtain the accurate mechanical strain. This section examined the feasibility of using this data-processing method to monitor the residual strain of concrete beams when the beams had the nonelastic response caused by a considerable load. If feasible, this technique could be used to assess the presence of residual strain after a bridge structure had been subjected to seismic forces, and could be a technique for easy and e ective assessment of damage to bridge structures. The dimensions of the beam and the load configuration used for the test were the same as in Figure 9 in Section 3.2. A steel plate with a thickness of 1 mm was glued to the top of the concrete beam to avoid brittle failure of the beam. The test period was 44 hours, and three time points were selected for short-term load application and removal. To enable the test specimen to generate nonelastic responses, a relatively large load (approximately 110 kgf) was given; residual strain occurred after load removal. Figure 13 shows the time-history response of the apparent strain at the beam bottom obtained by the test; a relatively large strain response (marked by the red dotted-line rectangle) generated by the three short-term load applications can be observed in the figure. Generally, in static monitoring of bridges, data are mostly retrieved at 10-minute or longer intervals. Therefore, a short-term seismic force response could not be recorded in a static apparent strain response. To simulate this type of scenario, the study eliminated the short-term large apparent strain response marked by the three red dotted-line rectangles in Figure 13. Figure 13. The apparent strain response of the nonelastic response test for the concrete beam. Figure 14a shows the apparent strain time-history curve obtained after deleting the strain data caused by the short-term loads, and Figure 14b shows the temperature change curve recorded during the test. Figure 13c shows the mechanical strain (" ) obtained by eliminating the temperature strain (" ) induced by the temperature change (DT) in Figure 14b from the apparent strain (") of Figure 14a. The mechanical strain in Figure 14c was significantly a ected by temperature drift, and was practically impossible to analyze. Using the same processing method as used in the previous section, the adjacent Appl. Sci. 2019, 9, 1662 11 of 13 data subtraction method was applied to the mechanical strain data in Figure 14c to obtain the change in mechanical strain per unit time, as illustrated in Figure 14d. Figure 14d clearly indicates that residual strains of 3.54, 5.78, and 4.91 " occurred at the three short-term load application time points. Figure 14. The concrete beam nonelastic response test: (a) strain response after deleting short-term loads; (b) beam bottom temperature changes; (c) mechanical strain; (d) change in mechanical strain per unit time. The preliminary test in this section already proved the proposed concept: given that temperature changes are slow and mechanical strain changes are momentary, application of adjacent data subtraction to mechanical strain data can eliminate the e ects of temperature drift. In addition to accurately analyzing the mechanical strains of load application and removal, this type of concept could also be used to analyze the residual strain of the nonelastic response of the concrete beam generated by the application of substantial short-term loads. 5. Conclusions This study used a wireless resistance strain gauge measurement system to measure the strain response of beams. The research performed long-term load tests for a steel beam and a concrete beam, and nonelastic response tests for a concrete beam, to examine the e ects of temperature changes on the strain responses obtained by the tests. Based on the test results, conclusions were obtained as follows: 1. When the load-generated mechanical response was smaller than the thermal strain response induced by temperature changes, the measured apparent strain response would be influenced by temperature changes, and the load-generated mechanical strain could not be obtained through analyzing apparent strain. 2. Mechanical strain could be obtained by eliminating the temperature-induced strain from the apparent strain. The mechanical strain of abrupt changes generated by load application and removal could be observed in the mechanical strain time-history curve. However, because of the presence of temperature-induced drift, the mechanical strain response could not return to the Appl. Sci. 2019, 9, 1662 12 of 13 0 position even after the removal of all loads. Moreover, as time passed, the temperature drift e ect caused the mechanical strain to move further away from 0. This temperature drift made analyzing mechanical strain dicult. 3. Given that temperature changes are slow and mechanical strain changes are momentary, this study proposed a simple data-processing method, namely, to use adjacent data subtraction on the mechanical strain time-history curve to eliminate the temperature drift e ect. The obtained mechanical strain change per unit time can be used to accurately determine the mechanical strain generated by load application and removal. In addition to precise analysis of load-generated mechanical strain, the adjacent data subtraction of mechanical strain time-history data could also be used to analyze the residual strain of the nonelastic response of a concrete beam subjected to substantial short-term loads. Author Contributions: Conceptualization and methodology, Y.L.; measurements, Y.-W.C.; development sensors, Y.-T.L.; data analysis, Y.L., Y.-T.L. and Y.-W.C.; writing—original draft preparation, Y.L., Y.-T.L. and Y.-W.C. Funding: This work was sponsored by the Ministry of Science and Technology, Taiwan, ROC under Grant No. MOST 106-2221-E-005 -036 -MY3. Conflicts of Interest: The authors declare no conflict of interest. References 1. Chang, P.C.; Flatau, A.; Liu, S.C. Review Paper: Health Monitoring of Civil Infrastructure. Acoust. Speech Signal Process. Newslett. IEEE 2003, 2, 257–267. [CrossRef] 2. Farrar, C.R.; Worden, K. An introduction to structural health monitoring. Philos. Trans. A Math. Phys. Eng. Sci. 2007, 365, 303–315. [CrossRef] [PubMed] 3. Xia, Y.; Chen, B.; Weng, S.; Ni, Y.Q.; Xu, Y.L. Temperature e ect on vibration properties of civil structures: A literature review and case studies. JCSHM 2012, 2, 29–46. [CrossRef] 4. Kromanis, R. Structural Performance Evaluation of Bridges: Characterizing and Integrating Thermal Response. Ph.D. Thesis, University of Exeter, Exeter, UK, January 2015. 5. Li, H.N.; Ren, L.; Jia, Z.G.; Yi, T.H.; Li, D.S. State-of-the-art in structural health monitoring of large and complex civil infrastructures. JCSHM 2016, 6, 3–16. [CrossRef] 6. Chen, Z.; Zhou, X.; Wang, X.; Dong, L.; Qian, Y. Deployment of a Smart Structural Health Monitoring System for Long-Span Arch Bridges: A Review and a Case Study. Sensors 2017, 17, 2151. [CrossRef] [PubMed] 7. Zhou, G.D.; Yi, T.H. Recent developments on wireless sensor networks technology for bridge health monitoring. Math. Probl. Eng. 2013, 3, 1–33. [CrossRef] 8. Chae, M.J.; Yoo, H.S.; Kim, J.Y.; Cho, M.Y. Development of a wireless sensor network system for suspension bridge health monitoring. Automat. Constr. 2012, 21, 237–252. [CrossRef] 9. Lynch, J.P.; Loh, K.J. A Summary Review of Wireless Sensors and Sensor Networks for Structural Health Monitoring. Shock Vib. Digest 2006, 38, 91–128. [CrossRef] 10. Liu, C.; Teng, J.; Wu, N. A Wireless Strain Sensor Network for Structural Health Monitoring. Shock Vib. 2015, 2015, 1–13. [CrossRef] 11. Papadopoulos, K.; Morfiadakis, E.; Philippidis, T.P.; Lekou, D.J. Assessment of the strain gauge technique for measurement of wind turbine blade loads. Wind Energy 2000, 3, 35–65. [CrossRef] 12. Kulprapha, N.; Warnitchai, P. Structural health monitoring of continuous prestressed concrete bridges using ambient thermal responses. Eng. Struct. 2012, 40, 20–38. [CrossRef] 13. Ge, Y.; Elshafie, M.Z.E.B.; Dirar, S.; Middleton, C.R. The response of embedded strain sensors in concrete beams subjected to thermal loading. Constr. Build. Mater. 2014, 70, 279–290. [CrossRef] 14. Prakash, G.; Sadhu, A.; Narasimhan, S.; Brehe, J.M. Initial service life data towards structural health monitoring of a concrete arch dam. Struct. Contr. Health Monit. 2018, 25, 1–19. [CrossRef] 15. Newell, S.; Goggins, J. Investigation of Thermal Behaviour of a Hybrid Precasted Concrete Floor using Embedded Sensors. IJCSM 2018, 12, 66. [CrossRef] Appl. Sci. 2019, 9, 1662 13 of 13 16. Küsel, F.; Kearsley, E.; Butler, L.J.; Skorpen, S.A.; Elshafie, M.Z.E.B. Measured temperature e ects during the construction of a prestressed precast concrete bridge beam. In Proceedings of the International Conference on Concrete Repair, Rehabilitation and Retrofitting, Cape Town, South Africa, 19–21 November 2018. 17. Kaloop, M.R.; Hu, J.W.; Elbeltagi, E. Time-Series and Frequency-Spectrum Correlation Analysis of Bridge Performance Based on a Real-Time Strain Monitoring System. ISPRS Int. J. Geo. Inf. 2016, 5, 61. [CrossRef] 18. Chen, C.; Wang, Z.; Wang, Y.; Wang, T.; Luo, Z. Reliability Assessment for PSC Box-Girder Bridges Based on SHM Strain Measurements. J. Sens. 2017, 2017, 1–13. [CrossRef] © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).

Journal

Applied SciencesMultidisciplinary Digital Publishing Institute

Published: Apr 22, 2019

There are no references for this article.