Virtual scatter modulation for X-ray CT scatter correction using primary modulator

Virtual scatter modulation for X-ray CT scatter correction using primary modulator A new scatter estimation algorithm with a concept of virtual scatter modulation for X-ray scatter correction using primary modulator is proposed to reduce the aliasing errors in the estimated scatter. Virtual scatter modulation can be realized through dividing the measured primary-modulated image by the measured modulation function. After the division, the aggravation of the aliasing of primary due to the non-uniformity of the modulation function is largely transferred to that of scatter. Since scatter in general has less high frequencies than primary does, the aggravation of its aliasing is expected to be weaker, and therefore the overall aliasing can be reduced. A CatPhan©600 phantom and an anthropomorphic thorax phantom are scanned on a tabletop X-ray cone-beam computed tomography system to validate our proposed algorithm. On the Catphan phantom, the oscillations that are clearly observed in the central region of the Catphan scatter profile estimated using the original primary-modulation algorithm, are mostly eliminated with the proposed scatter modulation algorithm, leading to less residual artifacts and better CT number uniformity in the reconstructed image. Compared with 38.9 HU of CT nonuniformity in a selected uniform region when the primary-modulation algorithm is used, the new algorithm significantly reduces it to 4.5 HU, reaching the same level of uniformity as the ground truth reference. On the thorax phantom, overall better CT number uniformity is also achieved. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of X-Ray Science and Technology IOS Press

Virtual scatter modulation for X-ray CT scatter correction using primary modulator

Loading next page...
 
/lp/ios-press/virtual-scatter-modulation-for-x-ray-ct-scatter-correction-using-StUpRW10sD

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
IOS Press
Copyright
Copyright © 2017 © 2017 – IOS Press and the authors. All rights reserved
ISSN
0895-3996
eISSN
1095-9114
DOI
10.3233/XST-17251
pmid
28582954
Publisher site
See Article on Publisher Site

Abstract

A new scatter estimation algorithm with a concept of virtual scatter modulation for X-ray scatter correction using primary modulator is proposed to reduce the aliasing errors in the estimated scatter. Virtual scatter modulation can be realized through dividing the measured primary-modulated image by the measured modulation function. After the division, the aggravation of the aliasing of primary due to the non-uniformity of the modulation function is largely transferred to that of scatter. Since scatter in general has less high frequencies than primary does, the aggravation of its aliasing is expected to be weaker, and therefore the overall aliasing can be reduced. A CatPhan©600 phantom and an anthropomorphic thorax phantom are scanned on a tabletop X-ray cone-beam computed tomography system to validate our proposed algorithm. On the Catphan phantom, the oscillations that are clearly observed in the central region of the Catphan scatter profile estimated using the original primary-modulation algorithm, are mostly eliminated with the proposed scatter modulation algorithm, leading to less residual artifacts and better CT number uniformity in the reconstructed image. Compared with 38.9 HU of CT nonuniformity in a selected uniform region when the primary-modulation algorithm is used, the new algorithm significantly reduces it to 4.5 HU, reaching the same level of uniformity as the ground truth reference. On the thorax phantom, overall better CT number uniformity is also achieved.

Journal

Journal of X-Ray Science and TechnologyIOS Press

Published: Jan 1, 2017

There are no references for this article.