Studies on implementation of the Katsevich algorithm for spiral cone-beam CT

Studies on implementation of the Katsevich algorithm for spiral cone-beam CT Recently, Katsevich proposed the first exact helical cone-beam reconstruction algorithm that takes longitudinally truncated data collected from part of a scanning turn. A key theoretical basis is that any point inside the scanning helix belongs to one and only one PI-line. Unfortunately, he only provided a general formulation and did not describe the implementation details. To make this complicated algorithm more transparent, we report here specifically how to program the Katsevich algorithm in the planar detector geometry. As an important component, we also analyze the effects of various implementation parameters on the image quality. Our results are intended to be valuable for those who are interested in evaluating, improving and extending the Katsevich approach. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of X-Ray Science and Technology IOS Press

Studies on implementation of the Katsevich algorithm for spiral cone-beam CT

Loading next page...
 
/lp/ios-press/studies-on-implementation-of-the-katsevich-algorithm-for-spiral-cone-MWHX7xBoHO

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
IOS Press
Copyright
Copyright © 2004 by IOS Press, Inc
ISSN
0895-3996
eISSN
1095-9114
Publisher site
See Article on Publisher Site

Abstract

Recently, Katsevich proposed the first exact helical cone-beam reconstruction algorithm that takes longitudinally truncated data collected from part of a scanning turn. A key theoretical basis is that any point inside the scanning helix belongs to one and only one PI-line. Unfortunately, he only provided a general formulation and did not describe the implementation details. To make this complicated algorithm more transparent, we report here specifically how to program the Katsevich algorithm in the planar detector geometry. As an important component, we also analyze the effects of various implementation parameters on the image quality. Our results are intended to be valuable for those who are interested in evaluating, improving and extending the Katsevich approach.