Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Seismic verification and retrofitting of multi-column foundation of the Ohnaruto Bridge

Seismic verification and retrofitting of multi-column foundation of the Ohnaruto Bridge The Ohnaruto Bridge, one of the Honshu-Shikoku Bridges in Japan, is a three-span two-hinged stiffening-truss suspension bridge. Multi-column foundations were adopted for the towers. In the original seismic design of the Ohnaruto Bridge, an inland near-field earthquake was not considered for the design seismic force. In order to grasp the seismic performance, seismic performance verification was conducted, which concluded that the seismic capacity of the multi-column foundations was not sufficient. Steel pipes had been used as concrete formwork for the construction of the columns and they were left as protective member of the columns. Based on the seismic verification, it was concluded that the seismic capacity could be achieved if the steel pipes were considered as structural members. Therefore, corrosion protection of steel pipes has been carried out to keep the pipes in good condition and ensure they continue to serve this purpose. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Bridge Structures IOS Press

Seismic verification and retrofitting of multi-column foundation of the Ohnaruto Bridge

Bridge Structures , Volume 10 (2) – Jan 1, 2014

Loading next page...
 
/lp/ios-press/seismic-verification-and-retrofitting-of-multi-column-foundation-of-P04C02Udin
Publisher
IOS Press
Copyright
Copyright © 2014 by IOS Press, Inc
ISSN
1573-2487
eISSN
1744-8999
DOI
10.3233/BRS-140077
Publisher site
See Article on Publisher Site

Abstract

The Ohnaruto Bridge, one of the Honshu-Shikoku Bridges in Japan, is a three-span two-hinged stiffening-truss suspension bridge. Multi-column foundations were adopted for the towers. In the original seismic design of the Ohnaruto Bridge, an inland near-field earthquake was not considered for the design seismic force. In order to grasp the seismic performance, seismic performance verification was conducted, which concluded that the seismic capacity of the multi-column foundations was not sufficient. Steel pipes had been used as concrete formwork for the construction of the columns and they were left as protective member of the columns. Based on the seismic verification, it was concluded that the seismic capacity could be achieved if the steel pipes were considered as structural members. Therefore, corrosion protection of steel pipes has been carried out to keep the pipes in good condition and ensure they continue to serve this purpose.

Journal

Bridge StructuresIOS Press

Published: Jan 1, 2014

There are no references for this article.