Access the full text.
Sign up today, get DeepDyve free for 14 days.
A. Einstein, M. Henzlova, S. Rajagopalan (2007)
Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography.JAMA, 298 3
Z. Bian, Jianhua Ma, Jing Huang, Hua Zhang, S. Niu, Qianjin Feng, Zhengrong Liang, Wufan Chen
Computerized Medical Imaging and Graphics Sr-nlm: a Sinogram Restoration Induced Non-local Means Image Filtering for Low-dose Computed Tomography
L. Shi, X. Yin, Libo Zhang, Benqiang Yang, Jie Zhan, Yang Chen, H. Shu, LiminLuo (2015)
Improving Low-Dose Brain Perfusion Computed Tomography Using 3D Dictionary Learning Based ProcessingJournal of Medical Imaging and Health Informatics, 5
Yang Chen, Zhou Yang, Yining Hu, Guanyu Yang, Yongcheng Zhu, Yinsheng Li, L. Luo, Wufan Chen, C. Toumoulin (2012)
Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal meansPhysics in Medicine and Biology, 57
M. Wintermark, M. Lev (2010)
FDA Investigates the Safety of Brain Perfusion CTAmerican Journal of Neuroradiology, 31
Yang Gao, Z. Bian, Jing Huang, Yunwan Zhang, S. Niu, Qianjin Feng, Wufan Chen, Zhengrong Liang, Jianhua Ma (2014)
Low-dose X-ray computed tomography image reconstruction with a combined low-mAs and sparse-view protocol.Optics express, 22 12
Yang Lu, Jun Zhao, Ge Wang (2012)
Few-view image reconstruction with dual dictionariesPhysics in Medicine and Biology, 57
S. Ravishankar, Y. Bresler (2011)
MR Image Reconstruction From Highly Undersampled k-Space Data by Dictionary LearningIEEE Transactions on Medical Imaging, 30
Yang Chen, Luyao Shi, Qianjin Feng, Jian Yang, H. Shu, L. Luo, J. Coatrieux, Wufan Chen (2014)
Artifact Suppressed Dictionary Learning for Low-Dose CT Image ProcessingIEEE Transactions on Medical Imaging, 33
Yang Chen, X. Yin, Luyao Shi, H. Shu, L. Luo, J. Coatrieux, C. Toumoulin (2013)
Improving abdomen tumor low-dose CT images using a fast dictionary learning based processingPhysics in Medicine and Biology, 58
Yang Chen, Wufan Chen, X. Yin, X. Ye, X. Bao, L. Luo, Qianjin Feng, Yinsheng Li, Xiaoe Yu (2011)
Improving low-dose abdominal CT images by Weighted Intensity Averaging over Large-scale Neighborhoods.European journal of radiology, 80 2
Michael Elad, M. Aharon (2006)
Image Denoising Via Sparse and Redundant Representations Over Learned DictionariesIEEE Transactions on Image Processing, 15
A. Cenic, D. Nabavi, R. Craen, A. Gelb, Ting-Yim Lee (1999)
Dynamic CT measurement of cerebral blood flow: a validation study.AJNR. American journal of neuroradiology, 20 1
Qiong Xu, Hengyong Yu, X. Mou, Lei Zhang, J. Hsieh, Ge Wang (2012)
Low-Dose X-ray CT Reconstruction via Dictionary LearningIEEE Transactions on Medical Imaging, 31
T. Boutelier, K. Kudo, Fabrice Pautot, M. Sasaki (2012)
Bayesian Hemodynamic Parameter Estimation by Bolus Tracking Perfusion Weighted ImagingIEEE Transactions on Medical Imaging, 31
S. Chen, D. Donoho, M. Saunders (1998)
Atomic Decomposition by Basis PursuitSIAM J. Sci. Comput., 20
S. Niu, Yang Gao, Z. Bian, Jing Huang, Wufan Chen, Gaohang Yu, Zhengrong Liang, Jianhua Ma (2014)
Sparse-view x-ray CT reconstruction via total generalized variation regularizationPhysics in Medicine and Biology, 59
Bian (2015)
Motion adaptive sparsity prior for low-dose dynamic CT myocardial perfusion imaging, inFully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine
Sheng Tan, Yanbo Zhang, Ge Wang, X. Mou, Guohua Cao, Zhifang Wu, Hengyong Yu (2015)
Tensor-based dictionary learning for dynamic tomographic reconstructionPhysics in Medicine & Biology, 60
X. Mou, Junfeng Wu, T. Bai, Qiong Xu, Hengyong Yu, Ge Wang (2014)
Dictionary learning based low-dose x-ray CT reconstruction using a balancing principle, 9212
E. Hoeffner, Ian Case, R. Jain, S. Gujar, G. Shah, J. Deveikis, R. Carlos, B. Thompson, M. Harrigan, S. Mukherji (2004)
Cerebral perfusion CT: technique and clinical applications.Radiology, 231 3
F. Calamante, D. Gadian, A. Connelly (2003)
Quantification of bolus‐tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularizationMagnetic Resonance in Medicine, 50
K. Mouridsen, Karl Friston, N. Hjort, Louise Gyldensted, L. Østergaard, S. Kiebel (2006)
Bayesian estimation of cerebral perfusion using a physiological model of microvasculatureNeuroImage, 33
Jing Huang, Yunwan Zhang, Jianhua Ma, D. Zeng, Z. Bian, S. Niu, Qianjin Feng, Zhengrong Liang, Wufan Chen (2013)
Iterative Image Reconstruction for Sparse-View CT Using Normal-Dose Image Induced Total Variation PriorPLoS ONE, 8
Hua Zhang, O. Luo, Jianhua Ma, Jing Huang, Wufan Chen, Jing Wang (2014)
Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT.Medical physics, 41 3
Jianhua Ma, Hua Zhang, Yang Gao, Jing Huang, Zhengrong Liang, Qianjin Feng, Wufan Chen (2012)
Iterative image reconstruction for cerebral perfusion CT using a pre-contrast scan induced edge-preserving priorPhysics in Medicine and Biology, 57
M. Debatin, J. Hesser (2015)
Accurate low-dose iterative CT reconstruction from few projections by Generalized Anisotropic Total Variation minimization for industrial CT.Journal of X-ray science and technology, 23 6
Zhang (2013)
Iterative reconstruction for x-ray computed tomography using priorimage induced nonlocal regularizationIEEE Trans Biomed Eng, 61
D. Kazantsev, E. Guo, A. Kaestner, W. Lionheart, J. Bent, P. Withers, P. Lee (2016)
Temporal sparsity exploiting nonlocal regularization for 4D computed tomography reconstructionJournal of X-Ray Science and Technology, 24
Hua Zhang, O. Luo, Jing Huang, Jianhua Ma, Wufan Chen, Jing Wang (2014)
Few-view cone-beam CT reconstruction with deformed prior image.Medical physics, 41 12
R. Fang, Tsuhan Chen, P. Sanelli (2013)
Towards robust deconvolution of low-dose perfusion CT: Sparse perfusion deconvolution using online dictionary learningMedical image analysis, 17 4
Lili He, Burkay Orten, Synho Do, W. Karl, A. Kambadakone, D. Sahani, H. Pien (2010)
A Spatio-Temporal Deconvolution Method to Improve Perfusion CT QuantificationIEEE Transactions on Medical Imaging, 29
S. Valiollahzadeh, John Clark, O. Mawlawi (2015)
Dictionary learning for data recovery in positron emission tomographyPhysics in Medicine & Biology, 60
S. Mukherjee, P. Raghavan, C. Phillips (2010)
Computed tomography perfusion: acute stroke and beyond.Seminars in roentgenology, 45 2
J. Hopyan, A. Ciarallo, D. Dowlatshahi, P. Howard, V. John, R. Yeung, Liying Zhang, Jisung Kim, Genevieve MacFarlane, Ting-Yim Lee, R. Aviv (2010)
Certainty of stroke diagnosis: incremental benefit with CT perfusion over noncontrast CT and CT angiography.Radiology, 255 1
C. McCollough, A. Primak, Natalie Braun, J. Kofler, Lifeng Yu, J. Christner (2009)
Strategies for reducing radiation dose in CT.Radiologic clinics of North America, 47 1
Bo Zhao, H. Ding, Yang Lu, Ge Wang, Jun Zhao, S. Molloi (2012)
Dual-dictionary learning-based iterative image reconstruction for spectral computed tomography applicationPhysics in Medicine and Biology, 57
R. Fang, Shaoting Zhang, Tsuhan Chen, P. Sanelli (2015)
Robust Low-Dose CT Perfusion Deconvolution via Tensor Total-Variation RegularizationIEEE Transactions on Medical Imaging, 34
J. Astrup, B. Siesjö, L. Symon (1981)
Thresholds in cerebral ischemia - the ischemic penumbra.Stroke, 12 6
Bian (2013)
SR-NLM: A sinogram restoration induced non-local means image filtering for low-dose computed tomographyComput Med Imaging Graph, 37
Jianhua Ma, Jing Huang, Qianjin Feng, Hua Zhang, Hongbing Lu, Zhengrong Liang, Wufan Chen (2011)
Low-dose computed tomography image restoration using previous normal-dose scan.Medical physics, 38 10
Yang Chen, Dazhi Gao, Cong Nie, L. Luo, Wufan Chen, X. Yin, Yazhong Lin (2009)
Bayesian statistical reconstruction for low-dose X-ray computed tomography using an adaptive-weighting nonlocal priorComputerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society, 33 7
M. Aharon, Michael Elad, A. Bruckstein (2006)
$rm K$-SVD: An Algorithm for Designing Overcomplete Dictionaries for Sparse RepresentationIEEE Transactions on Signal Processing, 54
M. Supanich, Yinghua Tao, Brian Nett, K. Pulfer, J. Hsieh, P. Turski, C. Mistretta, H. Rowley, Guang-Hong Chen (2009)
Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstructionPhysics in Medicine & Biology, 54
A. Mendrik, E. Vonken, B. Ginneken, H. Jong, A. Riordan, T. Seeters, E. Smit, M. Viergever, M. Prokop (2011)
TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow mapsPhysics in Medicine & Biology, 56
Chen (2001)
Atomic decomposition by basis pursuitSIAM Review, 43
Max Wintermark, Jean-Philippe Thiran, Philippe Maeder, Pierre Schnyder, R. Meuli (2001)
Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: a validation study.AJNR. American journal of neuroradiology, 22 5
W. Kalender, H. Wolf, C. Suess, M. Gies, H. Greess, W. Bautz (1999)
Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadaversEuropean Radiology, 9
Dynamic cerebral perfusion x-ray computed tomography (PCT) imaging has been advocated to quantitatively and qualitatively assess hemodynamic parameters in the diagnosis of acute stroke or chronic cerebrovascular diseases. However, the associated radiation dose is a significant concern to patients due to its dynamic scan protocol. To address this issue, in this paper we propose an image restoration method by utilizing coupled dictionary learning (CDL) scheme to yield clinically acceptable PCT images with low-dose data acquisition. Specifically, in the present CDL scheme, the 2D background information from the average of the baseline time frames of low-dose unenhanced CT images and the 3D enhancement information from normal-dose sequential cerebral PCT images are exploited to train the dictionary atoms respectively. After getting the two trained dictionaries, we couple them to represent the desired PCT images as spatio-temporal prior in objective function construction. Finally, the low-dose dynamic cerebral PCT images are restored by using a general DL image processing. To get a robust solution, the objective function is solved by using a modified dictionary learning based image restoration algorithm. The experimental results on clinical data show that the present method can yield more accurate kinetic enhanced details and diagnostic hemodynamic parameter maps than the state-of-the-art methods.
Journal of X-Ray Science and Technology – IOS Press
Published: Jan 1, 2016
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.