Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Region of interest micro-CT of the middle ear: A practical approach

Region of interest micro-CT of the middle ear: A practical approach Computed microtomography (μCT) is an imaging technique that produces virtual slices of an object, based on a set of x-ray images taken while the object is stepwise rotated. The stack of slices is calculated with a backprojection algorithm, it demands that the entire object remains within the x-ray beam for all observed angles. During region-of-interest (ROI) tomography however, one zooms in on a small part of the object. As a consequence the above condition is no longer fulfilled; the input data become incomplete and reconstructed slices are corrupted. In this study we show that, if we are not interested in grayscale values but only in geometrical information, conventional backprojection algorithms still perform well for ROI tomography. We demonstrate this with ROI scans performed on several phantom objects and we show ROI images of the gerbil hearing organ. We found that the resolution could considerably be improved and small details, not visible in a conventional full object scan, can be revealed by a ROI scan. One can use the benefits of ROI-μCT in situations where physical constrains are such that large parts of the object exceed the field of view (FOV), or where a very high magnification is required. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of X-Ray Science and Technology IOS Press

Region of interest micro-CT of the middle ear: A practical approach

Loading next page...
 
/lp/ios-press/region-of-interest-micro-ct-of-the-middle-ear-a-practical-approach-0gkz2eWaoo

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
IOS Press
Copyright
Copyright © 2005 by IOS Press, Inc
ISSN
0895-3996
eISSN
1095-9114
Publisher site
See Article on Publisher Site

Abstract

Computed microtomography (μCT) is an imaging technique that produces virtual slices of an object, based on a set of x-ray images taken while the object is stepwise rotated. The stack of slices is calculated with a backprojection algorithm, it demands that the entire object remains within the x-ray beam for all observed angles. During region-of-interest (ROI) tomography however, one zooms in on a small part of the object. As a consequence the above condition is no longer fulfilled; the input data become incomplete and reconstructed slices are corrupted. In this study we show that, if we are not interested in grayscale values but only in geometrical information, conventional backprojection algorithms still perform well for ROI tomography. We demonstrate this with ROI scans performed on several phantom objects and we show ROI images of the gerbil hearing organ. We found that the resolution could considerably be improved and small details, not visible in a conventional full object scan, can be revealed by a ROI scan. One can use the benefits of ROI-μCT in situations where physical constrains are such that large parts of the object exceed the field of view (FOV), or where a very high magnification is required.

Journal

Journal of X-Ray Science and TechnologyIOS Press

Published: Jan 1, 2005

There are no references for this article.