Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Monochromatic Imaging of X-Ray Source by Many-Beam Dynamical Diffraction

Monochromatic Imaging of X-Ray Source by Many-Beam Dynamical Diffraction We tested the X-ray monochromatic single crystal imaging method proposed by Fraenkel and Kalman (B. S. Fraenkel and Z. H. Kalman, Physica Scripta 41, 400 (1990)) on the basis of combined polarization factors. We performed dynamical calculation of the angular distribution of intensity of the imaging reflection. It was verified that the polarization of the incident wave has really a decisive role for an applicability of the method. An integrated intensity procedure was developed for simulating the conditions during practical imaging. Its applicability is examined in detail for three cases of multiple diffraction with the primary reflection 420 in Ge crystal. Only two cases of the three mentioned showed to be adjustable, producing sufficiently sharp image. A contrast of the image of the adjusted crystal on background level was calculated for those two cases. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of X-Ray Science and Technology IOS Press

Monochromatic Imaging of X-Ray Source by Many-Beam Dynamical Diffraction

Loading next page...
 
/lp/ios-press/monochromatic-imaging-of-x-ray-source-by-many-beam-dynamical-0PWsQKVIwm

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
IOS Press
Copyright
Copyright © 1997 by IOS Press, Inc
ISSN
0895-3996
eISSN
1095-9114
Publisher site
See Article on Publisher Site

Abstract

We tested the X-ray monochromatic single crystal imaging method proposed by Fraenkel and Kalman (B. S. Fraenkel and Z. H. Kalman, Physica Scripta 41, 400 (1990)) on the basis of combined polarization factors. We performed dynamical calculation of the angular distribution of intensity of the imaging reflection. It was verified that the polarization of the incident wave has really a decisive role for an applicability of the method. An integrated intensity procedure was developed for simulating the conditions during practical imaging. Its applicability is examined in detail for three cases of multiple diffraction with the primary reflection 420 in Ge crystal. Only two cases of the three mentioned showed to be adjustable, producing sufficiently sharp image. A contrast of the image of the adjusted crystal on background level was calculated for those two cases.

Journal

Journal of X-Ray Science and TechnologyIOS Press

Published: Jan 1, 1997

There are no references for this article.