Access the full text.
Sign up today, get DeepDyve free for 14 days.
Rongchang Chen, L. Rigon, Renata Longo (2013)
Comparison of single distance phase retrieval algorithms by considering different object composition and the effect of statistical and structural noise.Optics express, 21 6
T. Niu, Lei Zhu (2012)
Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: Phantom studies.Medical physics, 39 7Part2
L. Xu, Rende Chen, G. Du, Hong-lan Xie, T. Xiao (2015)
Fast X-ray micro-tomography for low-Z materialsJournal of Instrumentation, 10
B. Fahimian, Yu Mao, P. Cloetens, J. Miao (2010)
Low-dose x-ray phase-contrast and absorption CT using equally sloped tomographyPhysics in Medicine & Biology, 55
Seonmin Ahn, S. Kim, Jungah Son, D. Lee, Jae Lee (2012)
Gap compensation during PET image reconstruction by constrained, total variation minimization.Medical physics, 39 2
Hengyong Yu, Ge Wang (2009)
Compressed sensing based interior tomographyPhysics in Medicine & Biology, 54
Rong-Chang(陈荣昌) Chen, D. Dreossi, L. Mancini, R. Menk, L. Rigon, T. Xiao, R. Longo (2012)
PITRE: software for phase-sensitive X-ray image processing and tomography reconstruction.Journal of synchrotron radiation, 19 Pt 5
M. Beister, D. Kolditz, W. Kalender (2012)
Iterative reconstruction methods in X-ray CT.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics, 28 2
Honglan Xie, B. Deng, G. Du, Y. Fu, Rc Chen, Gz Zhou, Y. Ren, Yd Wang, YL(薛艳玲) Xue, G. Peng, Y. He, H. Guo, T. Xiao (2015)
Latest advances of X-ray imaging and biomedical applications beamline at SSRF, 26
E. Sidky, C. Kao, Xiaochuan Pan (2009)
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CTJournal of X-ray Science and Technology, 14
Yijin Liu, Johanna Nelson, C. Holzner, J. Andrews, Piero Pianetta (2013)
Recent advances in synchrotron-based hard x-ray phase contrast imagingJournal of Physics D: Applied Physics, 46
R. Siddon (1985)
Fast calculation of the exact radiological path for a three-dimensional CT array.Medical physics, 12 2
D. Stsepankou, A. Arns, SK Ng, P. Zygmanski, Jürgen Hesser (2012)
Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularizationPhysics in Medicine and Biology, 57
A. Momose, W. Yashiro, S. Harasse, Hiroaki Kuwabara (2011)
Four-dimensional X-ray phase tomography with Talbot interferometry and white synchrotron radiation: dynamic observation of a living worm.Optics express, 19 9
Wu Dong, Zeng Li, Deng Xiang (2015)
Prior image constrained low-rank matrix decomposition method in limited-angle reverse helical cone-beam CT.Journal of X-ray science and technology, 23 6
Xiaoli Yang, R. Hofmann, R. Dapp, T. Kamp, T. Rolo, Xianghui Xiao, J. Moosmann, Jubin Kashef, R. Stotzka (2015)
TV-based conjugate gradient method and discrete L-curve for few-view CT reconstruction of X-ray in vivo data.Optics express, 23 5
Rongchang Chen, Ping Liu, T. Xiao, L. Xu (2014)
X‐ray Imaging for Non‐Destructive Microstructure Analysis at SSRFAdvanced Materials, 26
B. Fahimian, Yunzhe Zhao, Zhifeng Huang, R. Fung, Yu Mao, Chun Zhu, M. Khatonabadi, J. DeMarco, S. Osher, M. McNitt-Gray, J. Miao (2013)
Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction.Medical physics, 40 3
Liang Xu, Rongchang Chen, G. Du, Yiming Yang, Feixiang Wang, B. Deng, Honglan Xie, T. Xiao (2016)
Anisotropic shrinkage of insect air sacs revealed in vivo by X-ray microtomographyScientific Reports, 6
Guang-Hong Chen, Jie Tang, S. Leng (2008)
Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.Medical physics, 35 2
Huihua Kong, R. Liu, Hengyong Yu (2016)
Ordered-subset Split-Bregman algorithm for interior tomography.Journal of X-ray science and technology, 24 2
Malcolm Hudson, Richard LarkinAbstract (1994)
Accelerated image reconstruction using ordered subsets of projection dataIEEE transactions on medical imaging, 13 4
Xueli Li, S. Luo (2011)
A compressed sensing-based iterative algorithm for CT reconstruction and its possible application to phase contrast imagingBioMedical Engineering OnLine, 10
Honglan Xie, B. Deng, G. Du, Y. Fu, Y. He, H. Guo, G. Peng, Y. Xue, G. Zhou, Yuqi Ren, Yong Wang, Rende Chen, Y. Tong, T. Xiao (2013)
X-ray biomedical imaging beamline at SSRFJournal of Instrumentation, 8
L. Rudin, S. Osher, E. Fatemi (1992)
Nonlinear total variation based noise removal algorithmsPhysica D: Nonlinear Phenomena, 60
K. Lange, R. Carson (1984)
EM reconstruction algorithms for emission and transmission tomography.Journal of computer assisted tomography, 8 2
T. Rolo, A. Ershov, T. Kamp, T. Baumbach (2014)
In vivo X-ray cine-tomography for tracking morphological dynamicsProceedings of the National Academy of Sciences, 111
C. Puncreobutr, P. Lee, K. Kareh, T. Connolley, J. Fife, A. Phillion (2014)
Influence of Fe-rich intermetallics on solidification defects in Al–Si–Cu alloysActa Materialia, 68
D. Baker, F. Brun, C. O’Shaughnessy, L. Mancini, J. Fife, M. Rivers (2012)
A four-dimensional X-ray tomographic microscopy study of bubble growth in basaltic foamNature Communications, 3
J. Miao, F. Förster, O. Levi (2005)
Equally sloped tomography with oversampling reconstructionPhysical Review B, 72
A. Jerri (1977)
The Shannon sampling theorem—Its various extensions and applications: A tutorial reviewProceedings of the IEEE, 65
Monochromatic-beam-based dynamic X-ray computed microtomography (CT) was developed to observe evolution of microstructure inside samples. However, the low flux density results in low efficiency in data collection. To increase efficiency, reducing the number of projections should be a practical solution. However, it has disadvantages of low image reconstruction quality using the traditional filtered back projection (FBP) algorithm. In this study, an iterative reconstruction method using an ordered subset expectation maximization-total variation (OSEM-TV) algorithm was employed to address and solve this problem. The simulated results demonstrated that normalized mean square error of the image slices reconstructed by the OSEM-TV algorithm was about 1/4 of that by FBP. Experimental results also demonstrated that the density resolution of OSEM-TV was high enough to resolve different materials with the number of projections less than 100. As a result, with the introduction of OSEM-TV, the monochromatic-beam-based dynamic X-ray microtomography is potentially practicable for the quantitative and non-destructive analysis to the evolution of microstructure with acceptable efficiency in data collection and reconstructed image quality.
Journal of X-Ray Science and Technology – IOS Press
Published: Jan 1, 2017
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.