Image performance evaluation of a cone beam O-arm imaging system

Image performance evaluation of a cone beam O-arm imaging system Image performance of a cone beam O-arm system with the use of a Varian flat panel detector (PaxScan 4030CB) was evaluated. Modulation Transfer Function (MTF), Noise Power Spectrum (NPS), and tube output characteristics were measured. Image quality measurements were performed with a CATPHAN 424 phantom using a 120 kVp beam filtered with 1 mm Al and 0.1 mm Cu and three preset protocols at different exposure levels. The CPT445 Module was used to measure MTF. Water phantom images were used to calculate NPS. Then the NPS was normalized by dividing the square of the mean signal. The Photon fluence at each exposure (q) was estimated using the SpekCalc. The MTF indicates that the reconstruction filter of the O-arm is overenhancing, meaning that it yields values greater than unity. The system has a 10% MTF at 0.45 mm. The NPS shows the low frequency structured noise. The evaluation of image performance of the O-arm imaging system helps its future improvements and clinical applications. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of X-Ray Science and Technology IOS Press

Image performance evaluation of a cone beam O-arm imaging system

Loading next page...
 
/lp/ios-press/image-performance-evaluation-of-a-cone-beam-o-arm-imaging-system-1P0SK3nB3B

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
IOS Press
Copyright
Copyright © 2013 by IOS Press, Inc
ISSN
0895-3996
eISSN
1095-9114
DOI
10.3233/XST-130385
pmid
24004867
Publisher site
See Article on Publisher Site

Abstract

Image performance of a cone beam O-arm system with the use of a Varian flat panel detector (PaxScan 4030CB) was evaluated. Modulation Transfer Function (MTF), Noise Power Spectrum (NPS), and tube output characteristics were measured. Image quality measurements were performed with a CATPHAN 424 phantom using a 120 kVp beam filtered with 1 mm Al and 0.1 mm Cu and three preset protocols at different exposure levels. The CPT445 Module was used to measure MTF. Water phantom images were used to calculate NPS. Then the NPS was normalized by dividing the square of the mean signal. The Photon fluence at each exposure (q) was estimated using the SpekCalc. The MTF indicates that the reconstruction filter of the O-arm is overenhancing, meaning that it yields values greater than unity. The system has a 10% MTF at 0.45 mm. The NPS shows the low frequency structured noise. The evaluation of image performance of the O-arm imaging system helps its future improvements and clinical applications.

Journal

Journal of X-Ray Science and TechnologyIOS Press

Published: Jan 1, 2013

There are no references for this article.