Purpose: The purpose of this study was to compare the dosimetric characteristics for protection of the hippocampus between dual arc VMAT (volumetric modulated arc therapy) and 7 fields intensity-modulated radiation therapy (7F-IMRT) for patients with brain metastases from lung cancer under the whole brain radiotherapy.Methods: Based on ten cases with brain metastases from lung cancer, two types of radiotherapy plans were designed, namely, dual arc VMAT and 7F-IMRT. Provided that the clinical requirements were satisfied, the comparisons of target dose distribution, conformity index (CI), homogeneity index (HI), dose of organs at risk (OARs), monitor units (MU) and treatment time between dual arc VMAT and 7F-IMRT were investigated for their dosimetric difference.Results: Both treatment plans met the requirements of clinical treatments. However, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT (P < 0.05). As to OARs, the mean maximum doses (Dmax) of hippocampus, eyes and optic nerves in the dual arc VMAT plan were all lower than those in 7F-IMRT plan (P < 0.05), but the result had no statistical significance (P < 0.05) for the maximum dose of lens. Compared with 7F-IMRT, dual arc VMAT reduced the average number of MU by 67% and the average treatment time by 74%. Therefore, treatment time was shortened by dual arc VMAT.Conclusion: With regards to the patients with brain metastases from lung cancer under the whole brain radiotherapy, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT under the precise of meeting the clinical requirements. In addition, dual arc VMAT remarkably reduced the irradiation dose to OARs (hippocampus, eyes and optic nerves), MU and treatment time, as well, guaranteed patients with better protection.
http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.pngJournal of X-Ray Science and TechnologyIOS Presshttp://www.deepdyve.com/lp/ios-press/comparison-between-dual-arc-vmat-and-7f-imrt-in-the-protection-of-LmDs5d8cvF
Comparison between Dual Arc VMAT and 7F-IMRT in the protection of hippocampus for patients during whole brain radiotherapy
Purpose: The purpose of this study was to compare the dosimetric characteristics for protection of the hippocampus between dual arc VMAT (volumetric modulated arc therapy) and 7 fields intensity-modulated radiation therapy (7F-IMRT) for patients with brain metastases from lung cancer under the whole brain radiotherapy.Methods: Based on ten cases with brain metastases from lung cancer, two types of radiotherapy plans were designed, namely, dual arc VMAT and 7F-IMRT. Provided that the clinical requirements were satisfied, the comparisons of target dose distribution, conformity index (CI), homogeneity index (HI), dose of organs at risk (OARs), monitor units (MU) and treatment time between dual arc VMAT and 7F-IMRT were investigated for their dosimetric difference.Results: Both treatment plans met the requirements of clinical treatments. However, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT (P < 0.05). As to OARs, the mean maximum doses (Dmax) of hippocampus, eyes and optic nerves in the dual arc VMAT plan were all lower than those in 7F-IMRT plan (P < 0.05), but the result had no statistical significance (P < 0.05) for the maximum dose of lens. Compared with 7F-IMRT, dual arc VMAT reduced the average number of MU by 67% and the average treatment time by 74%. Therefore, treatment time was shortened by dual arc VMAT.Conclusion: With regards to the patients with brain metastases from lung cancer under the whole brain radiotherapy, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT under the precise of meeting the clinical requirements. In addition, dual arc VMAT remarkably reduced the irradiation dose to OARs (hippocampus, eyes and optic nerves), MU and treatment time, as well, guaranteed patients with better protection.
Journal
Journal of X-Ray Science and Technology
– IOS Press
Published: Jan 1, 2016
Recommended Articles
Loading...
References
Phase III comparison of prophylactic cranial irradiation versus observation in patients with locally advanced non-small-cell lung cancer: Primary analysis of radiation therapy oncology group study RTOG 0214 (vol 29, pg 272, 2011)
Gore
Adjuvant whole brain radiotherapy versus observation after radiosurgery or surgical resection of 1-3 cerebral metastases - results of the EORTC 2-1 study
Kocher
Postoperative radiotherapy in the treatment of single metastases to the brain - A randomized trial
Patchell
Hypofractionated stereotactic radiotherapy and radiosurgery for the treatment of patients with radioresistant brain metastases
Scorsetti
Effects of radiotherapy on cognitive function in patients with low-grade glioma measured by the Folstein Mini-Mental State Examination
Brown
Phase III comparison of prophylactic cranial irradiation versus observation in patients with locally advanced non-small-cell lung cancer: Primary analysis of radiation therapy oncology group study RTOG
Gore
Why avoid the hippocampus? A comprehensive review
Gondi
Hippocampal-sparing whole-brain radiotherapy: A "how-to" technique using helical tomotherapy and linear accelerator-based intensity-modulated radiotherapy:
Gondi
Estimated risk of perihippocampal disease progression after hippocampal avoidance during whole-brain radiotherapy: Safety profile for RTOG
Gondi
Sparing of the hippocampus, limbic circuit and neural stem cell compartment during partial brain radiotherapy for glioma: A dosimetric feasibility study
Marsh
Sparing of the neural stem cell compartment during whole-brain radiation therapy: A dosimetric study using helical tomotherapy
Marsh
Recursive partitioning analysis (RPA) of prognostic factors in three Radiation Therapy Oncology Group (RTOG) brain metastases trials
Gaspar
Distribution of brain metastases in relation to the hippocampus: Implications for neurocognitive functional preservation
Ghia
Whole-brain radiotherapy in the management of brain metastasis
Khuntia
Intensity-modulated radiation therapy in the treatment of head and neck cancer
Eisbruch
Planning and delivery of intensity- modulated radiation therapy
Yu
Tolerance of normal tissue to therapeutic irradiation
Emami
Impact of prolonged fraction delivery times on tumor control: A note of caution for intensity-modulated radiation therapy (IMRT)
Volumetric modulated arc therapy: IMRT in a single gantry arc
Otto
Commissioning and quality assurance of rapidarc radiotherapy delivery system: In Regard to Ling Et Al. (Int J Radiat Oncol Biol Phys 72 (2008), (575–581): Absence of Data Does Not Constitute Proof; the Proof Is in Tasting the Pudding
Mehta
RapidArc volumetric modulated therapy planning for prostate cancer patients
Kjaer-Kristoffersen
Risk assessment of radiation-induced malignancies based on whole-body equivalent dose estimates for IMRT treatment in the head and neck region
Verellen
Clinical implementation of intensity-modulated arc therapy (IMAT) for rectal cancer
Duthoy
Whole abdominopelvic radiotherapy (WAPRT) using intensity-modulated arc therapy (IMAT): First clinical experience
Duthoy
Anatomy-based, patient-specific VMAT QA using EPID or MLC log files
Defoor
Multi-GPU implementation of a VMAT treatment plan optimization algorithm
To get new article updates from a journal on your personalized homepage, please log in first, or sign up for a DeepDyve account if you don’t already have one.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.