Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Comparison between Dual Arc VMAT and 7F-IMRT in the protection of hippocampus for patients during whole brain radiotherapy

Comparison between Dual Arc VMAT and 7F-IMRT in the protection of hippocampus for patients during... Purpose: The purpose of this study was to compare the dosimetric characteristics for protection of the hippocampus between dual arc VMAT (volumetric modulated arc therapy) and 7 fields intensity-modulated radiation therapy (7F-IMRT) for patients with brain metastases from lung cancer under the whole brain radiotherapy.Methods: Based on ten cases with brain metastases from lung cancer, two types of radiotherapy plans were designed, namely, dual arc VMAT and 7F-IMRT. Provided that the clinical requirements were satisfied, the comparisons of target dose distribution, conformity index (CI), homogeneity index (HI), dose of organs at risk (OARs), monitor units (MU) and treatment time between dual arc VMAT and 7F-IMRT were investigated for their dosimetric difference.Results: Both treatment plans met the requirements of clinical treatments. However, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT (P < 0.05). As to OARs, the mean maximum doses (Dmax) of hippocampus, eyes and optic nerves in the dual arc VMAT plan were all lower than those in 7F-IMRT plan (P < 0.05), but the result had no statistical significance (P < 0.05) for the maximum dose of lens. Compared with 7F-IMRT, dual arc VMAT reduced the average number of MU by 67% and the average treatment time by 74%. Therefore, treatment time was shortened by dual arc VMAT.Conclusion: With regards to the patients with brain metastases from lung cancer under the whole brain radiotherapy, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT under the precise of meeting the clinical requirements. In addition, dual arc VMAT remarkably reduced the irradiation dose to OARs (hippocampus, eyes and optic nerves), MU and treatment time, as well, guaranteed patients with better protection. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of X-Ray Science and Technology IOS Press

Comparison between Dual Arc VMAT and 7F-IMRT in the protection of hippocampus for patients during whole brain radiotherapy

Loading next page...
 
/lp/ios-press/comparison-between-dual-arc-vmat-and-7f-imrt-in-the-protection-of-LmDs5d8cvF

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
IOS Press
Copyright
Copyright © 2016 IOS Press and the authors. All rights reserved
ISSN
0895-3996
eISSN
1095-9114
DOI
10.3233/XST-160561
pmid
27257881
Publisher site
See Article on Publisher Site

Abstract

Purpose: The purpose of this study was to compare the dosimetric characteristics for protection of the hippocampus between dual arc VMAT (volumetric modulated arc therapy) and 7 fields intensity-modulated radiation therapy (7F-IMRT) for patients with brain metastases from lung cancer under the whole brain radiotherapy.Methods: Based on ten cases with brain metastases from lung cancer, two types of radiotherapy plans were designed, namely, dual arc VMAT and 7F-IMRT. Provided that the clinical requirements were satisfied, the comparisons of target dose distribution, conformity index (CI), homogeneity index (HI), dose of organs at risk (OARs), monitor units (MU) and treatment time between dual arc VMAT and 7F-IMRT were investigated for their dosimetric difference.Results: Both treatment plans met the requirements of clinical treatments. However, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT (P < 0.05). As to OARs, the mean maximum doses (Dmax) of hippocampus, eyes and optic nerves in the dual arc VMAT plan were all lower than those in 7F-IMRT plan (P < 0.05), but the result had no statistical significance (P < 0.05) for the maximum dose of lens. Compared with 7F-IMRT, dual arc VMAT reduced the average number of MU by 67% and the average treatment time by 74%. Therefore, treatment time was shortened by dual arc VMAT.Conclusion: With regards to the patients with brain metastases from lung cancer under the whole brain radiotherapy, the PTV-HA conformity and homogeneity of dual arc VMAT were superior to those of 7F-IMRT under the precise of meeting the clinical requirements. In addition, dual arc VMAT remarkably reduced the irradiation dose to OARs (hippocampus, eyes and optic nerves), MU and treatment time, as well, guaranteed patients with better protection.

Journal

Journal of X-Ray Science and TechnologyIOS Press

Published: Jan 1, 2016

References