Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Calculation of effective atomic numbers using a rational polynomial approximation method with a dual-energy X-ray imaging system

Calculation of effective atomic numbers using a rational polynomial approximation method with a... The study aims to develop a rational polynomial approximation method for improving the accuracy of the effective atomic number calculation with a dual-energy X-ray imaging system. This method is based on a multi-materials calibration model with iterative optimization, which can improve the calculation accuracy of the effective atomic number by adding a rational term without increasing the computation time. The performance of the proposed rational polynomial approximation method is demonstrated and validated by both simulated and experimental studies. The twelve reference materials are used to establish the effective atomic number calibration model, and the value of the effective atomic numbers are between 5.444 and 22. For the accuracy of the effective atomic number calculation, the relative differences between calculated and experimental values are less than 8.5%for all sample cases in this study. The average calculation accuracy of the method proposed in this study can be improved by about 40%compared with the conventional polynomial approximation method. Additionally, experimental quality assurance phantom imaging result indicates that the proposed method is compliant with the international baggage inspection standards for detecting the explosives. Moreover, the experimental imaging results reveal that the difference of color between explosives and the surrounding materials is in significant contrast for the dual-energy image with the proposed method. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of X-Ray Science and Technology IOS Press

Calculation of effective atomic numbers using a rational polynomial approximation method with a dual-energy X-ray imaging system

Loading next page...
 
/lp/ios-press/calculation-of-effective-atomic-numbers-using-a-rational-polynomial-ScJh0UriHN

References (19)

Publisher
IOS Press
Copyright
Copyright © 2021 © 2021 – IOS Press. All rights reserved
ISSN
0895-3996
eISSN
1095-9114
DOI
10.3233/XST-200790
Publisher site
See Article on Publisher Site

Abstract

The study aims to develop a rational polynomial approximation method for improving the accuracy of the effective atomic number calculation with a dual-energy X-ray imaging system. This method is based on a multi-materials calibration model with iterative optimization, which can improve the calculation accuracy of the effective atomic number by adding a rational term without increasing the computation time. The performance of the proposed rational polynomial approximation method is demonstrated and validated by both simulated and experimental studies. The twelve reference materials are used to establish the effective atomic number calibration model, and the value of the effective atomic numbers are between 5.444 and 22. For the accuracy of the effective atomic number calculation, the relative differences between calculated and experimental values are less than 8.5%for all sample cases in this study. The average calculation accuracy of the method proposed in this study can be improved by about 40%compared with the conventional polynomial approximation method. Additionally, experimental quality assurance phantom imaging result indicates that the proposed method is compliant with the international baggage inspection standards for detecting the explosives. Moreover, the experimental imaging results reveal that the difference of color between explosives and the surrounding materials is in significant contrast for the dual-energy image with the proposed method.

Journal

Journal of X-Ray Science and TechnologyIOS Press

Published: Mar 11, 2021

There are no references for this article.