A practical material decomposition method for x-ray dual spectral computed tomography

A practical material decomposition method for x-ray dual spectral computed tomography X-ray dual spectral CT (DSCT) scans the measured object with two different x-ray spectra, and the acquired rawdata can be used to perform the material decomposition of the object. Direct calibration methods allow a faster material decomposition for DSCT and can be separated in two groups: image-based and rawdata-based. The image-based method is an approximative method, and beam hardening artifacts remain in the resulting material-selective images. The rawdata-based method generally obtains better image quality than the image-based method, but this method requires geometrically consistent rawdata. However, today’s clinical dual energy CT scanners usually measure different rays for different energy spectra and acquire geometrically inconsistent rawdata sets, and thus cannot meet the requirement. This paper proposes a practical material decomposition method to perform rawdata-based material decomposition in the case of inconsistent measurement. This method first yields the desired consistent rawdata sets from the measured inconsistent rawdata sets, and then employs rawdata-based technique to perform material decomposition and reconstruct material-selective images. The proposed method was evaluated by use of simulated FORBILD thorax phantom rawdata and dental CT rawdata, and simulation results indicate that this method can produce highly quantitative DSCT images in the case of inconsistent DSCT measurements. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of X-Ray Science and Technology IOS Press

A practical material decomposition method for x-ray dual spectral computed tomography

Journal of X-Ray Science and Technology , Volume 24 (3): 19 – Jan 1, 2016

Loading next page...
 
/lp/ios-press/a-practical-material-decomposition-method-for-x-ray-dual-spectral-nIyof6YumA

References (35)

Publisher
IOS Press
Copyright
Copyright © 2016 IOS Press and the authors. All rights reserved
ISSN
0895-3996
eISSN
1095-9114
DOI
10.3233/XST-160544
pmid
27257878
Publisher site
See Article on Publisher Site

Abstract

X-ray dual spectral CT (DSCT) scans the measured object with two different x-ray spectra, and the acquired rawdata can be used to perform the material decomposition of the object. Direct calibration methods allow a faster material decomposition for DSCT and can be separated in two groups: image-based and rawdata-based. The image-based method is an approximative method, and beam hardening artifacts remain in the resulting material-selective images. The rawdata-based method generally obtains better image quality than the image-based method, but this method requires geometrically consistent rawdata. However, today’s clinical dual energy CT scanners usually measure different rays for different energy spectra and acquire geometrically inconsistent rawdata sets, and thus cannot meet the requirement. This paper proposes a practical material decomposition method to perform rawdata-based material decomposition in the case of inconsistent measurement. This method first yields the desired consistent rawdata sets from the measured inconsistent rawdata sets, and then employs rawdata-based technique to perform material decomposition and reconstruct material-selective images. The proposed method was evaluated by use of simulated FORBILD thorax phantom rawdata and dental CT rawdata, and simulation results indicate that this method can produce highly quantitative DSCT images in the case of inconsistent DSCT measurements.

Journal

Journal of X-Ray Science and TechnologyIOS Press

Published: Jan 1, 2016

There are no references for this article.