Access the full text.
Sign up today, get DeepDyve free for 14 days.
Y. Zou, M. Silver (2008)
Analysis of fast kV-switching in dual energy CT using a pre-reconstruction decomposition technique, 6913
(2009)
Optimal Spectral Filtration for Dual-Energy and Dual-Source CT
Xing Zhao, Jingjing Hu, Yunsong Zhao, Hui-Tao Zhang, Peng Zhang (2014)
Iterative dual energy material decomposition from spatial mismatched raw data sets.Journal of X-ray science and technology, 22 6
E. Sidky, Lifeng Yu, Xiaochuan Pan, Y. Zou, M. Vannier (2005)
A robust method of x-ray source spectrum estimation from transmission measurements: Demonstrated on computer simulated, scatter-free transmission dataJournal of Applied Physics, 97
A. Primak, J. Giraldo, Xin Liu, Lifeng Yu, C. McCollough (2009)
Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration.Medical physics, 36 4
T. Flohr, C. McCollough, H. Bruder, M. Petersilka, Klaus Gruber, Christoph Süβ, M. Grasruck, K. Stierstorfer, B. Krauss, R. Raupach, A. Primak, A. Küttner, S. Achenbach, C. Becker, A. Kopp, B. Ohnesorge (2006)
First performance evaluation of a dual-source CT (DSCT) systemEuropean Radiology, 16
I. Elbakri, J. Fessler (2002)
Statistical image reconstruction for polyenergetic X-ray computed tomographyIEEE Transactions on Medical Imaging, 21
Yining Zhu, Yunsong Zhao, Xing Zhao (2012)
A multi-thread scheduling method for 3D CT image reconstruction using multi-GPU.Journal of X-ray science and technology, 20 2
A. Coleman, M. Sinclair (1985)
A beam-hardening correction using dual-energy computed tomography.Physics in medicine and biology, 30 11
R. Alvarez, A. Macovski (1976)
Energy-selective reconstructions in X-ray computerized tomography.Physics in medicine and biology, 21 5
M. Petersilka, H. Bruder, B. Krauss, K. Stierstorfer, T. Flohr (2008)
Technical principles of dual source CT.European journal of radiology, 68 3
R. Johnson, M. Reiser (2011)
Dual energy CT in clinical practice
W. Kalender, W. Kalender, W. Perman, W. Perman, J. Vetter, J. Vetter, Ernst Klotz, Ernst Klotz (1986)
Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies.Medical physics, 13 3
R. Brooks, G. Chiro (1976)
Beam hardening in x-ray reconstructive tomography.Physics in medicine and biology, 21 3
Z. Ying, R. Naidu, C. Crawford (2006)
Dual energy computed tomography for explosive detectionJournal of X-ray Science and Technology, 14
Paul Kinahan, A. Alessio, J. Fessler (2006)
Dual Energy CT Attenuation Correction Methods for Quantitative Assessment of Response to Cancer Therapy with PET/CT ImagingTechnology in Cancer Research & Treatment, 5
J. Fornaro, S. Leschka, D. Hibbeln, A. Butler, N. Anderson, G. Pache, H. Scheffel, S. Wildermuth, H. Alkadhi, P. Stolzmann (2011)
Dual- and multi-energy CT: approach to functional imagingInsights into Imaging, 2
Ruoqiao Zhang, Jean-Baptiste Thibault, C. Bouman, K. Sauer, J. Hsieh (2014)
Model-Based Iterative Reconstruction for Dual-Energy X-Ray CT Using a Joint Quadratic Likelihood ModelIEEE Transactions on Medical Imaging, 33
Yunsong Zhao, Xing Zhao, Peng Zhang (2015)
An Extended Algebraic Reconstruction Technique (E-ART) for Dual Spectral CTIEEE Transactions on Medical Imaging, 34
Dan Xu, D. Langan, Xiaoye Wu, J. Pack, Thomas Benson, J. Tkaczky, Andrea Schmitz (2009)
Dual energy CT via fast kVp switching spectrum estimation, 7258
Hui Xue, Li Zhang, Zhiqiang Chen, Liang Li (2012)
A correction method for dual energy liquid CT image reconstruction with metallic containers.Journal of X-ray science and technology, 20 3
Xing Zhao, Jingjing Hu, Yunsong Zhao, Hui-Tao Zhang (2014)
A novel iterative reconstruction method for dual-energy computed tomography based on polychromatic forward-projection calibrationInsight, 56
C. Maass, E. Meyer, M. Kachelriess (2011)
Exact dual energy material decomposition from inconsistent rays (MDIR).Medical physics, 38 2
W. Huh, J. Fessler (2009)
Model-based image reconstruction for dual-energy X-ray CT with fast KVP switching2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro
Guowei Zhang, Jianping Cheng, Li Zhang, Zhiqiang Chen, Yuxiang Xing (2008)
A practical reconstruction method for dual energy computed tomographyJournal of X-ray Science and Technology, 16
C. Maass, M. Baer, M. Kachelriess (2009)
Image-based dual energy CT using optimized precorrection functions: A practical new approach of material decomposition in image domain.Medical physics, 36 8
Qiong Xu, X. Mou, Shao-jie Tang, Wei Hong, Yizhai Zhang, Tao Luo (2009)
Implementation of penalized-likelihood statistical reconstruction for polychromatic dual-energy CT, 7258
J. Vetter, W. Perman, W. Kalender, R. Mazess, James Holden (1986)
Evaluation of a prototype dual-energy computed tomographic apparatus. II. Determination of vertebral bone mineral content.Medical physics, 13 3
M. Knaup, P. Stenner, Marc Kachelriess (2007)
Rawdata-Based Dual Energy CT (DECT) from inconsistent scans2007 IEEE Nuclear Science Symposium Conference Record, 6
P. Sukovic, N. Clinthorne (2000)
Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomographyIEEE Transactions on Medical Imaging, 19
Xing Zhao, Jingjing Hu, Tao Yang (2013)
GPU based iterative cone-beam CT reconstruction using empty space skipping technique.Journal of X-ray science and technology, 21 1
T. Szczykutowicz, Guang-Hong Chen (2010)
Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensingPhysics in Medicine & Biology, 55
P. Stenner, T. Berkus, M. Kachelriess (2007)
Empirical dual energy calibration (EDEC) for cone-beam computed tomography.Medical Physics, 34
Joonki Noh, J. Fessler, Paul Kinahan (2009)
Statistical Sinogram Restoration in Dual-Energy CT for PET Attenuation CorrectionIEEE Transactions on Medical Imaging, 28
G. Herman (2009)
Fundamentals of Computerized Tomography: Image Reconstruction from Projections
X-ray dual spectral CT (DSCT) scans the measured object with two different x-ray spectra, and the acquired rawdata can be used to perform the material decomposition of the object. Direct calibration methods allow a faster material decomposition for DSCT and can be separated in two groups: image-based and rawdata-based. The image-based method is an approximative method, and beam hardening artifacts remain in the resulting material-selective images. The rawdata-based method generally obtains better image quality than the image-based method, but this method requires geometrically consistent rawdata. However, today’s clinical dual energy CT scanners usually measure different rays for different energy spectra and acquire geometrically inconsistent rawdata sets, and thus cannot meet the requirement. This paper proposes a practical material decomposition method to perform rawdata-based material decomposition in the case of inconsistent measurement. This method first yields the desired consistent rawdata sets from the measured inconsistent rawdata sets, and then employs rawdata-based technique to perform material decomposition and reconstruct material-selective images. The proposed method was evaluated by use of simulated FORBILD thorax phantom rawdata and dental CT rawdata, and simulation results indicate that this method can produce highly quantitative DSCT images in the case of inconsistent DSCT measurements.
Journal of X-Ray Science and Technology – IOS Press
Published: Jan 1, 2016
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.