Measurement of blood acetoacetate and β-hydroxybutyrate in an automatic analyser

Measurement of blood acetoacetate and β-hydroxybutyrate in an automatic analyser Clinical Biochemistry Service, Hospital Universitario Germans Trias i Pujol, Carretera del Canyet s/n, Badalona, Barcelona, Spain. 1 e-mail: agalan@ns. hugtip.scs.es ­ -hydroxybutyrate and acetoacetate as well as lactate and pyruvate are intermediary metabolites normally present in blood. The ­ hydroxybutyrate/acetoacetate ratio is an expression of the mitochondrial oxido-reduction state. This ketone body ratio can provide a clue to diagnosis and metabolic status in congenital errors of the electron transport chain and pyruvate metabolism. The standardization of these analytical procedures improves the interpretation of the results helping in the di¤cult diagnosis of mitochondrial diseases in children. This study describes an adaptation to a Dimension R £ L (Dade Behring, Newark, Delaware, USA) automatic analyser for a method to measure blood ketone bodies (­ -hydroxybutyrate and acetoacetate). The method allows the metabolites to be measured directly in nondeproteinized plasma (£uoride/ethylenediaminetetraacetic acid). This adaptation simpli¢es the analytical procedure and limits the turnaround time to 20 minutes. With a sample volume of 200 ml metabolite concentrations ranging from 12 to 1300 mmol L¡1 of ­ -hydroxybutyrate and from 10 to 450 mmol L¡1 of acetoacetate may be measured with a reliable analytical response. fuel homeostasi s such as disorders of the Krebs cycle, disorders of the mitochondrial respiratory chain, ketogenesis or ketolysis [3± 5]. In these cases the evaluation of the lactate/pyruvate ratio together with the b-hydroxybutyrate/acetoacetate ratio are the tools of ® rst choice in determining the cytoplasmatic and mitochondrial oxido-reduction state respectively of the individual [4]. The ® rst application of these assays is in the screening for the diagnosis of mitochondrial cytopathie s [6]. The determination of these ratios in the basal state or following an eÃ¥ ort test [4, 7], may diagnose or discount a mitochondrial cytopathy. If these test results are normal, a biopsy may be avoided. Spectrophotometri c determinations of circulating acetoacetate and hydroxybutyrat e have been reported [8, 9] and adapted to several automatic analysers [10± 14]. The quanti® cation of ketone bodies presents technical (manual preparation of reagents, complexity of the preanalytical phase, long analytical response times) and diagnostic (intraindividual variations, wide reference ranges, need for support from other biochemical parameters for result interpretation) interpretation diæ culties [15]. With the aim of standardizing the analytical procedures and facilitating their application as routine techniques we have adapted the methods proposed by Vassault et al. [16] to measure ketone bodies on a Dimension R £ L (Dade Behring, Newark, Delaware, USA) automatic analyser. The study was performed on two types of sample: deproteinized plasma with perchloric acid and afterwards alkalinized, and plasma obtained directly with ¯ uoride/ethylenediaminetetraaceti c acid (EDTA). Introduction Ketone bodies are produced in the liver, mainly from the oxidation of fatty acids, and are exported to peripheral tissues for use as an energy source. The term ` ketone bodies’ refers to three molecules, acetoacetate, b-hydroxybutyrate and acetone. Acetoacetate and b-hydroxybutyrate transport energy from the liver to other tissues and acetone is generated by spontaneous decarboxylation of acetoacetate [1]. The presence of ketosis may be normal or pathologic. Normally ketosis implies that the lipid energy metabolism has been activated and the pathway of lipid degradation is intact. Ketosis is a physiological ® nding in many circumstances such as during fasting, after prolonged exercise or after a high fat diet. However, as a general rule, hyperketosis, at a level that produces metabolic acidosis is not physiologic. Pathological causes of ketosis include diabetes, childhood hypoglycaemia, corticosteroid or growth hormone de® ciency, intoxication with alcohol or salicylates and several inborn errors of metabolism, as well as multiple organ failure. Ketosis with an abnormal elevation of the b-hydroxybutyrate/acetoacetate ratio implies a disorder of the intramitochondrial redox state [2]. These situations may be present in inborn metabolic diseases that aÃ¥ ect Material and methods Principle of the method The two assays are based on end-point reactions catalysed by b-hydroxybutyrat e dehydrogenas e at 37 8C and diÃ¥ erent pH conditions. The generation or consumption of reduced nicotinamide ademine dinucleotide (NADH) is measured by changes in absorbance at 340 nm: b-hydroxybutyrate ‡ NAD¡ Á ¡ ¡ ¡ ¡ ¡ ! ¡¡¡¡¡¡ dehydrogenase b¡hydroxybutyrate acetoacetate ‡ NADH ¡ ‡ H‡ To complete the b-hydroxybutyrat e reaction a pH of 9.5 is necessary while the acetoacetate assay requires a pH of 7. Journal of Automated Methods & Management in Chemistry ISSN 1463± 9246 print/ISSN 1464± 5068 online # 2001 Taylor & Francis Ltd http://www.tandf.co.uk/journals Table 1. Settings for ­ -hydroxybutyrate determination by the dimension R £ L analyser. Reagent and sample delivery Setting Delivery time (s) Volume delivery (ml) Chase delivery (ml) Mix First reagent (R1) (NAD 168 mM) 760.0 20.0 0.0 None Second reagent (R2) (Tris 0.1M pH 9) 65.3 245.0 20.0 Moderate Third reagent (R3) (HBDH 15 U ml¡1 ) 125.3 12.0 20.0 Moderate Sample (S1) 0.0 60 0.0 None Photometric readings and calculation Mode Standard curve Measuring ® lter First ® lter Secondary ® lter Time of photometric readings P1 P2 Calculation mode Dilution Absorbance Logit 340 nm 700 nm 110 s 410 s Endpoint C ˆ A £ …¡0:915†‡ B £ …1:0†Reagents and work solutions b-Hydroxybutyrate . Reagent 1: 168 mmol L¡1 : nicotinamide adenine dinucleotide (NAD) (Roche catalogue 127841) in distilled water. Stable for 6 months when frozen at ¡20 8C in aliquots. . Reagent 2: 0.1 mol L¡1 tris buÃ¥ er (tris(hydroxymethyl)-aminomethane , Merck catatalogue 8382) adjusted to pH 9.5 with HCl. . Reagent 3: b-hydroxybutyrat e dehydrogenas e (EC1.1.1.30) (HBDH Roche catalogue 127841; speci® c activity: 3 U mg¡1 (25 8C). Stable at 4 8C. . b-hydroxybutyrat e standards to calibrate the method: d,l b-hydroxybutyri c acid, sodium salt (Sigma H6501). Prepare 0, 50, 250, 500 and 1250 mmol L¡1 solutions in distilled water. Stable for 6 months when frozen at ¡20 8C in aliquots. . Reagent 1: 4 mmol L¡1 NADH (Roche catalogue 128023) in distilled water. Stable for 6 months when frozen at ¡20 8C in aliquots. . Reagent 2: 0.1 mol L¡1 tris buÃ¥ er (tris(hydroxymethyl)-aminomethane , Merck catalogue 8382) adjusted to pH 7. . Reagent 3: b-hydroxybutyrat e dehydrogenas e (EC1.1.1.30) (Roche catalogue 127841); speci® c activity 3 U mg¡1 (25 8C). Stable at 4 8C. . Acetoacetate standards to calibrate the method: acetoacetic acid salt (Sigma, catalogue A-8509). Prepare 0, 50, 100, 200 and 400 mmol L¡1 solutions in distilled water. Stable for 4 weeks when frozen at ¡20 8C in aliquots. Reagents for specimen preparation For deproteinized plasma samples: 1 mol L¡1 perchloric acid (Merck catalogue 519) and 0.7 mol L¡1 tripotassium phosphate (Merck catalogue 5102). For plasma samples: ¯ uoride/EDTA (Roche catalogue 243710). Automated assay The settings used on the Dimension R £ L analyser are listed in tables 1 and 2. Calibration method Calibration was with b-hydroxybutyrat e and acetoacetate standards described in Reagents and work solutions above. b-Hydroxybutyrat e was calibrated following a logarithmic reaction and acetoacetat e a linear reaction. Subjects Reference values were calculated from 60 samples obtained from apparently normal children, and were sent to our laboratory for analytical control before minor surgical interventions were carried out on the patients. Blood samples were obtained after 12 hours of fasting. The age range of the children was 1 month to 14 years. The specimens were assayed the same day as the blood samples were obtained. 20 of these values were used to study the comparison between plasma and deproteinized plasma samples. 20 apparently normal subjects (age range 20± 60 years), 20 patients with diabetic ketosis and another 20 patients with metabolic disorders were also included in the study. Specimens The blood specimens (1 ml) were added immediately to tubes containing 1 ml cold 1 mol L¡1 perchloric acid. The samples were mixed and centrifuged (3000 £ g for 10 minutes). The deproteinized supernatants were stored at ¡20 8C until analysis. The supernatants were adjusted to Acetoacetate Table 2. Settings for acetoacetate determination by the Dimension R £ L analyser. Reagent and sample delivery Setting Delivery time (s) Volume delivery (ml) Chase delivery (ml) Mix First reagent (R1) (NAH 4 mM) 760.0 16.0 0.0 None Second reagent (R2) (Tris 0.1 M pH 7) 65.3 95.0 20.0 Moderate Third reagent (R3) (HBDH 15 U ml¡1 ) 125.3 5.0 20.0 Moderate Sample (S1) 0.0 95 0.0 None Photometric readings and calculation Mode Standard curve Measuring ® lter First ® lter Secondary ® lter Time of photometric readings P1 P2 Calculation mode Dilution Absorbance linear 340 nm 700 nm 110 s 560 s Endpoint C ˆ A £ …¡0:900†‡ B £ …1:0†pH 7 with 0.7 mol L¡1 tripotassium phosphate, stored for 15 minutes at 4 8C and then centrifuged. The alkalinized supernatants were used to measure the ketone bodies. To obtain plasma samples 1 ml blood was added to tubes containing 1 drop of ¯ uoride/EDTA and then mixed. The supernatants obtained after centrifuging at 3000 £ g for 10 minutes were stored at ¡20 8C and used to measure the ketone bodies. Quality control b-Hydroxbutyrat e and acetoacetate standards, at two levels, were always assayed with patient samples ® rst at one level and at the end of the batch at the other level. The assay was considered to be correct if the standard values were within §10% of the assigned value. Evaluation of the method The analytical interval and the detection limit of the methods were evaluated following the directions of the Socite¨ Franmaise de Biologie Clinique [17]. To calculate the analytical interval the following standard aqueous solutions were used: 2500, 2000, 1250, 500, 250, 100, 25, 0.1 mmol L¡1 of d,l-b-hydroxybutyri c acid, sodium salt, and 600, 500, 250, 100, 50, 25, 10, 5, 0.1 mmol L¡1 acetoacetic acid salt. The detection limit (Ld ) was established following the processing of 10 specimens of distilled water. With the mean (md ) and the standard deviation (SD) the detection limit for an ¬ and ­ risk of 5% (K ˆ 5:185) was calculated (Ld ˆ md ‡ K SD) [17]. The recommendations of the European Committee for Clinical Laboratory Standards (ECCLS) were followed for the study of the imprecision and inaccuracy of the method [18]. 50,100 and 200 mmol L¡1 hydroxybutyrate and acetoacetate standard aqueous solutions were used. 430, 700 and 1000 mmol L¡1 hydroxybutyrat e and 100, 200 and 400 mol L¡1 acetoacetate were the standard aqueous solutions used. The dilution eÃ¥ ect was corrected by adding the same volume of saline solution to unaltered samples. The reference values of the methods were obtained following the recommendations of the Panel of Experts of the International Federation of Clinical Chemistry on reference values [19]. Sample evaluation : deproteinized plasma or not b-Hydroxybutyrat e and acetoacetate were assayed in 80 patients in replicate using as samples plasma obtained directly with ¯ uoride/EDTA and deproteinized plasma with perchloric acid. Comparison studies were performed among the results from the two diÃ¥ erent samples. Statistical methods The mean, standard deviation and coeæ cient of variation for studying the accuracy, imprecision and detection limit were obtained. The Student’ s t test was applied to compare the types of sample. Regression analyses were applied to obtain the analytical interval. The Mann± Whitney test was applied to establish the statistical diÃ¥ erences between groups. To calculate the reference values of the method, the 2.5, 50 and 97.5 percentiles were used. Results Detection limit and analytical interval of methods The detection limit established was 12 mmol L¡1 for bhydroxybutyrat e and 6 mmol L¡1 for acetoacetate. The analytical interval of the methods ranged from 12 to 1300 mmol L¡1 for b-hydroxybutyrat e and from 10 to 450 mmol L¡1 for acetoacetate . Figure 1 shows the slope To determine the analytical recovery of the methods, increasing quantities of b-hydroxybutyrat e or acetoacetate were added to diÃ¥ erent aliquots of the pool of sera. Figure 1. Analytical interval for ­ -hydroxybutyrate. (ö), Reference line y ˆ bx (b ˆ 1); (- - - - -) regression line (y ˆ 1:023x ¡ 2:349); (>) mean and two standard deviations of each point. The mean values of the points found and their two ? standard deviations coincide with the reference line from 12 to 1300 mmol L¡1 . of linear regression of the least squares (y ˆ 1:023 £ ¡2:349; r ˆ 0:989) of the reference hydroxybutyrate standards processed in triplicate over 3 consecutive days, and the values found. The linear regression for the acetoacetate standard was y ˆ 1:020 £ ¡3:01 ; r ˆ 0:976) (® gure 2). tions of b-hydroxybutyrat e (t ˆ ¡0:287; p ˆ 0:775) and acetoacetate (t ˆ ¡0:430, p ˆ 0:669) using deproteinized plasma with perchloric and non-deproteinize d plasma (¯ uoride/EDTA) (table 7). Discussion The determination of levels of blood ketone bodies is an infrequent type of analysis in clinical biochemistry laboratories. There are several reasons for this. Firstly, clinical interpretation of these results is diæ cult because of intraindividual variations, thereby making it diæ cult to establish reference values. Secondly, there are many physiological situations in which ketosis may be produced, thus to achieve a correct diagnosis of hyperketosis, other metabolites, such as glucose, lactate, pyruvate or amino acids, should be measured simultaneously. Therefore, use of blood ketone bodies is restricted to some concrete and diæ cult diagnoses. An example is the investigation of inborn errors of intermediary metabolism, especially aÃ¥ ecting energetic homeostasi s (defects of the mitochondrial respiratory chain, b-oxidation, ketogenesis and ketolysis). Since the incidence of these diseases is low, few manufacturers have been motivated to elaborate commercial kits for measuring these metabolites and even less to implement them in an automatic Imprecision and inaccuracy. Table 3 demonstrates the within-run and between-run coeæ cients of variation of the aqueous standards of b-hydroxybutyrat e and acetoacetate at three concentration levels, as well as those of the serum specimen. The percentages of inaccuracy with respect to the theoretical value (table 4) did not exceed 10%. Analytical recovery study. Analytical recovery ranged from 97 to 104% for hydroxybutyrat e and 98 to 103% for acetoacetate (table 5). Reference values. Table 6 contains the reference values for the studied population which was divided into two groups (1 month to 7 years and 7 to 14 years). Statistical diÃ¥ erences between the two groups were found for the b-hydroxybutyrat e (p ˆ 0:032) and acetoacetat e (p ˆ 0:041) results, but no diÃ¥ erences were found for the b-hydroxybutyrate /acetoacetate ratio (p ˆ 0:200). Comparison between plasma and deproteinized plasma samples. No statistical diÃ¥ erences were found for the concentra72 Figure 2. Analytical interval for acetoacetate. (ö), Reference line y ˆ bx (b ˆ 1); (- - - - -) regression line (y ˆ 1:020x ¡ 3:01); (>) mean and two standard deviations of each point. The mean values of the points found and their two standard deviations coincide with ? the reference line from 10 to 450 mmol L¡1 . Table 3. Imprecision of the methods. b-Hydroxybutyrate Concentration level Aqueous b-hydroxybutyrate solution (50 mmol L¡1 ) Aqueous b-hydroxybutyrate solution (100 mmol L¡1 ) Aqueous b-hydroxybutyrate solution (200 mmol L¡1 ) Serum pool (170 mmol L¡1 ) Deproteinized plasma pool (110 mmol L¡1 ) Acetoacetate Concentration level Aqueous acetoacetate solution (50 mmol L¡1 ) Aqueous acetoacetate solution (100 mmol L¡1 ) Aqueous acetoacetate solution (200 mmol L¡1 ) Serum pool (96 mmol L¡1 ) Deproteinized plasma pool (141 mmol L¡1 ) N 20 20 20 20 20 Within-run CV(%) 5 4 3 4.5 4.9 Between-run (CV%) 9.5 9.1 7.3 Ð Ð N 20 20 20 20 20 Within-run CV(%) 6 5 4 5.1 5.2 Between-run (CV%) 9.5 9.1 7.3 Ð Ð analyser. The manual practice of these assays does not favour their use since the preparation of the reagents and the assay itself are laborious, time-consuming, require high reagent and sample volumes, and give elevated imprecisions [8, 9]. Similar to several previous works [10± 14], we have automated a spectrometric method [16] to measure ketone bodies in a Dimension R £ L analyser, which is available 24 hours a day in the laboratory. With this adaptation we have improved notably the analytical reliability of our results in addition to saving time, and reagent and sample volume. This is an important point to take into account since most samples are of paediatric origin. Moreover, complementary analyses must be performed to achieve the diagnosis Table 4. Inaccuracy of methods. b-Hydroxybutyrate Within-run Theoretica concentrationl (mmol L¡1 ) 50 100 200 Acetoacetate Within-run Theoretical concentration (mmol L¡1 ) 50 100 200 Mean found concentration (mmol L¡1 ) 48 98 195 Between-run Mean found concentration (mmol L¡1 ) 53 92 215 Mean found concentration (mmol L¡1 ) 53 101 198 Between-run Mean found concentration (mmol L¡1 ) 47 105 186 N 20 20 20 Inaccuracy (%) 6 1 71 Inaccuracy (%) 76 5 77 N 20 20 20 Inaccuracy (%) 74 72 72.5 Inaccuracy (%) 6 78.0 7.5 Table 5. Recovery study. b-Hydroxybutyrate b-Hydroxybutyrate added (mmol L¡1 ) 430 700 1000 Theoretical b-Hydroxybutyrate concentration (mmol L¡1 ) 630 900 1200 Found b-Hydroxybutyrate concentration (mmol L¡1 ) 655 873 1284 Serum pool (mmol L¡1 ) 200 200 200 Acetoacetate Recovery (%) 104 97 104 Serum pool (mmol L¡1 ) 80 80 80 Acetoacetate added (mmol L¡1 ) 100 200 400 Theoretical acetoacetate concentration (mmol L¡1 ) 180 280 480 Found acetoacetate concentration (mmol L¡1 ) 176 288 475 Recovery (%) 98 103 99 Table 6. Reference values. 0± 7 years (n ˆ 30) b-Hydroybutyrate (mmol L¡1 ) Range (p2:5 ; p97:5 ) Mean value (p50 ) Acetoacetate (mmol L¡1 ) Range (p2:5 ; p97:5 ) Mean value (p50†­ -Hydroybutyrate/acetoacetate Range (p2:5 ; p97:5 ) Mean value (p50 ) 74 20± 700 60 10± 200 45 0.04± 4.0 1.3 7± 14 years (n ˆ 30) 20± 500 40 10± 140 31 0.04± 3.5 1.1 Table 7. Comparison between deproteinized and non-deproteinized plasma as samples ­ -Hydroxybutyrate Mean value (mmol L¡1 ) 402.46 400.46 Standard deviation (mmol L¡1 ) 394.33 377.58 Range (mmol L¡1 ) 10± 1290 10± 1220 70.287 0.775 0.991 Pearson coeæ cient r Regression line y ˆ 1:035x ¡ 0:99 Sample Student’ s t Deproteinized 80 plasma (x) Plasma 80 (¯ uoride/EDTA) non-deproteinized ( y) Acetoacetate Sample Deproteinized plasma (x) Plasma (¯ uoride/EDTA) non-deproteinized (y) n 80 80 Mean value (mmol L¡1 ) 154.45 153.26 Standard deviation (mmol L¡1 ) 134.97 130.02 Range (mmol L¡1 ) 10± 450 Student’ s t 70.430 p 0.669 Pearson coeæ cient r 0.988 Regression line y ˆ 1:025x ¡ 1:637 10± 430 and they can be processed simultaneously in the same analyser. Another diæ culty, from the technical point of view, in analysing ketone bodies derives from sample collection. Acetoacetate is an unstable metabolite [16] thus it is recommended that the blood be collected immediately after its withdrawal in an acid medium to be deproteinized as well as the samples be maintained in ice until processing. Other authors [13, 16], who usually determine lactate, pyruvate and ketone bodies in the same sample, recommend the use of deproteinized plasma with perchloric acid. We also perform our assays in this type of sample. However, we have observed that the results using plasma collected directly in ¯ uoride/EDTA are similar to those obtained from deproteinized plasma with perchloric acid. On the other hand, statistically signi® cant diÃ¥ erences were found (n ˆ 80, t ˆ 8:08, p < 0:001) between using deproteinized plasma ( y) and non deproteinized plasma (¯ uoride/EDTA) (x) in the quanti® cation of pyruvate (y ˆ 1:74x ‡ 4:62; r ˆ 0:599) (data not included in the study). We did not observe diÃ¥ erences in the lactate values using these two types of sample (n ˆ 80, t ˆ 0:118, p ˆ 0:779). Thus, if the four metabolites are to be measured in the same sample it is necessary to use deproteinized plasma in an acid medium after extraction because the pyruvate values may be incorrect. However, the ketone bodies may be evaluated directly in a serum sample which has been withdrawn with ¯ uoride/EDTA with the aim of measuring its lactate for example. There are several advantages to working directly with non-deproteinized plasma. The possible dilution error (which falsi® es the absolute value of the metabolites although not their ratios) is minimized. Additionally, the analytical procedure is reduced by 30 minutes. The present adaptation, especially using nondeproteinized plasma, simpli® es the anaytical procedure and, although the preparation of reagents is somewhat laborious, the fact that they may be stored frozen, allows the assay to be performed with relative ease in emergency situations. We have established our reference values for a population under the age of 14 years. Signi® cant diÃ¥ erences were found in two age groups for the two metabolites, but not for their ratios. These results have been reported by Artuch et al. [13]. Similar to other reports [13, 20], our reference values present a wide range of values. Many intraindividual variations may be due to the nutritional state of the patient. In summary, this adaptation facilitates the measurement of sanguineous ketone bodies and provides a rapid and reliable method with low sample consumption and which may to be applied as a routine technique in an emergency laboratory. The main application of this method is to contribute to the diagnosis of mitochondrial diseases both in the ® rst orientation as well as in subsequent provocative tests [6, 7]. References 1. Guthrie, J. P. and Jordan, F., 1972, Amine-catalyzed decarboxylation of acetoacetic acid. The rate constant for decarboxylation of beta-immino acid. J. Am. Chem. Soc., 94, 9136. 2. Robinson, B. H., 1989, Lactic acidemia. In: C. R. Scriver, A. L. Beaudet, Ws. Sly and D. Valle (eds) The Metabolic Basis of Inherited Disease (New York: McGraw-Hill), p. 869. 3. Roth, K. S., 1991, Inborn errors of metabolism: the essentials of clinical diagnosis. Clin. Pediatr., 30, 183. 4. Munnich, A., RÃŽtig, A., Chretien, D., Saudubray, J. M., Cormier, V. and Rustin, P., 1996, Clinical presentation and laboratory investigations in respiratory chain de® ciency. Eur. J. Pediatr., 155, 262. 5. Poggi, F., Rabier, D., Vassault, A., Charpentier, C., Kamoun, P. and Saudubray, J. M., 1994, Protocole d’ investigations metaboliques dans les maladies hereditaries du metabolisme. Arch. ¨ ¨ ¨ Pediatr., 1, 667. ¨ © 6. Galan, A., Coll, J., Padros, A., Arambarri, M. and Pintos, G., 1999, Estrategia diagnostica de las enfermedades mitocondriales. © Rev. Neurol., 29, 52. 7. Bonnefont, J. P., Specola, N. B., Vassault, A., Lombes, A., Ogier, H., de Klerk, J. B. C. et al., 1990, The Fasting test in paediatrics: application to the diagnosis of pathological hypo and hyperketonic states. Eur. J. Pediatr., 150, 80. Williamson, D. H. and Mellanby, J., 1974, D-3-Hydroxybutyrate. In: H. U. Bergmeyer (ed.) Methods of Enzymatic Analysis (New York: Academic Press), p. 1836. Mellanby, J. and Williamson, D. H., 1974, Acetoacetate. In: H. U. Bergmeyer (ed.) Methods of Enzymatic Analysis (New York: Academic Press), p. 1840 Nuwayhid, N. F., Johnson, G. F. and Feld, R. D., 1989, Multipoint kinetic method for simultaneously measuring the combined concentrations of acetoacetate-b-hydroxybutyrate and lactate-pyruvate. Clin. Chem., 35, 1526. Hansen, J. L. and Freier, E. F., 1978, Direct assays of lactate, pyruvate, b-hydroxybutyrate and acetoacetate with a centrifugal analyzer. Clin. Chem., 24, 475. Li, P. K., Lee, J. T., MacGillivray, M. H., Schaefer, P. A. and Siegel, J. H., 1980, Direct, ® xed-time kinetic assays for b-hydroxybutyrate and acetoacetate with a centrifugal analyzer or a computer-backed spectrophotometer. Clin. Chem., 26, 1713. ¨ Artuch, R., Vilaseca, M. A, Farre, C. and Ramon, F., 1995, Determination of lactate, pyruvate, b-hydroxybutyrate and acetoacetate with a centrifugal analyser. Eur. J. Clin. Chem. Clin. Biochem., 33, 529. 14. Uno, S., Takehiro, O., Tabata, R. and Ozawa, K., 1995, Enzymatic method for determining ketone body ratio arterial blood. Clin. Chem., 41, 1745. 15. Mitchell, G. A., Kassovska-Bratinova, S., Boukaftane, Y., Robert, M.-F., Wang, S. P., Ashmarina, L., Lambert, M., Lapierre, P. and Potier, E., 1995, Medical aspects of ketone body metabolism. Clin. Invest. Med., 18, 193. 16. Vassault, A., Bonnefont, J. P., Specola, N. and Saudubray, J. M., 1991, Lactate, Pyruvate and Ketone Bodies. Techniques in Diagnostic Human Biochemical Genetics: A Laboratory Manual (New York: Wiley-Liss) p. 285. ¨ 17. Societe Franc aise de Biologie Clinique, 1986, Commission ° ` Validation de techniques’ . Protocole de validation de techniques. Ann. Biol. Clin., 44, 686. 18. European Committee for Clinical Laboratory Standards, 1986, Guidelines for the evaluation of analyzers in clinical chemistry. ECCLS Document, 3(2). 19. International Federation of Clinical Chemistry, 1987, Approved recommendation (1987) on the theory of reference values. Part 5. Statistical treatment of collected reference values. Determinations of reference limits. Clin. Chem. Acta, S13-S32, 170. 20. Lamers, K. J. B., Doesburg, W. H., Gabreels, F. J. M., Romsom, « A. C., Renier, W. O., Wevers, R. A. and Lemmens, W. A., 1985, Reference values of blood components related to fuel metabolism in children after an overnight fast. Clin. Chim. Acta, 145, 17. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Automated Methods and Management in Chemistry Hindawi Publishing Corporation

Measurement of blood acetoacetate and β-hydroxybutyrate in an automatic analyser

Loading next page...
 
/lp/hindawi-publishing-corporation/measurement-of-blood-acetoacetate-and-hydroxybutyrate-in-an-automatic-a4wS4oUvhl
Publisher
Hindawi Publishing Corporation
Copyright
Copyright © 2001 Hindawi Publishing Corporation.
ISSN
1463-9246
eISSN
1464-5068
Publisher site
See Article on Publisher Site

Abstract

Clinical Biochemistry Service, Hospital Universitario Germans Trias i Pujol, Carretera del Canyet s/n, Badalona, Barcelona, Spain. 1 e-mail: agalan@ns. hugtip.scs.es ­ -hydroxybutyrate and acetoacetate as well as lactate and pyruvate are intermediary metabolites normally present in blood. The ­ hydroxybutyrate/acetoacetate ratio is an expression of the mitochondrial oxido-reduction state. This ketone body ratio can provide a clue to diagnosis and metabolic status in congenital errors of the electron transport chain and pyruvate metabolism. The standardization of these analytical procedures improves the interpretation of the results helping in the di¤cult diagnosis of mitochondrial diseases in children. This study describes an adaptation to a Dimension R £ L (Dade Behring, Newark, Delaware, USA) automatic analyser for a method to measure blood ketone bodies (­ -hydroxybutyrate and acetoacetate). The method allows the metabolites to be measured directly in nondeproteinized plasma (£uoride/ethylenediaminetetraacetic acid). This adaptation simpli¢es the analytical procedure and limits the turnaround time to 20 minutes. With a sample volume of 200 ml metabolite concentrations ranging from 12 to 1300 mmol L¡1 of ­ -hydroxybutyrate and from 10 to 450 mmol L¡1 of acetoacetate may be measured with a reliable analytical response. fuel homeostasi s such as disorders of the Krebs cycle, disorders of the mitochondrial respiratory chain, ketogenesis or ketolysis [3± 5]. In these cases the evaluation of the lactate/pyruvate ratio together with the b-hydroxybutyrate/acetoacetate ratio are the tools of ® rst choice in determining the cytoplasmatic and mitochondrial oxido-reduction state respectively of the individual [4]. The ® rst application of these assays is in the screening for the diagnosis of mitochondrial cytopathie s [6]. The determination of these ratios in the basal state or following an eå ort test [4, 7], may diagnose or discount a mitochondrial cytopathy. If these test results are normal, a biopsy may be avoided. Spectrophotometri c determinations of circulating acetoacetate and hydroxybutyrat e have been reported [8, 9] and adapted to several automatic analysers [10± 14]. The quanti® cation of ketone bodies presents technical (manual preparation of reagents, complexity of the preanalytical phase, long analytical response times) and diagnostic (intraindividual variations, wide reference ranges, need for support from other biochemical parameters for result interpretation) interpretation diæ culties [15]. With the aim of standardizing the analytical procedures and facilitating their application as routine techniques we have adapted the methods proposed by Vassault et al. [16] to measure ketone bodies on a Dimension R £ L (Dade Behring, Newark, Delaware, USA) automatic analyser. The study was performed on two types of sample: deproteinized plasma with perchloric acid and afterwards alkalinized, and plasma obtained directly with ¯ uoride/ethylenediaminetetraaceti c acid (EDTA). Introduction Ketone bodies are produced in the liver, mainly from the oxidation of fatty acids, and are exported to peripheral tissues for use as an energy source. The term ` ketone bodies’ refers to three molecules, acetoacetate, b-hydroxybutyrate and acetone. Acetoacetate and b-hydroxybutyrate transport energy from the liver to other tissues and acetone is generated by spontaneous decarboxylation of acetoacetate [1]. The presence of ketosis may be normal or pathologic. Normally ketosis implies that the lipid energy metabolism has been activated and the pathway of lipid degradation is intact. Ketosis is a physiological ® nding in many circumstances such as during fasting, after prolonged exercise or after a high fat diet. However, as a general rule, hyperketosis, at a level that produces metabolic acidosis is not physiologic. Pathological causes of ketosis include diabetes, childhood hypoglycaemia, corticosteroid or growth hormone de® ciency, intoxication with alcohol or salicylates and several inborn errors of metabolism, as well as multiple organ failure. Ketosis with an abnormal elevation of the b-hydroxybutyrate/acetoacetate ratio implies a disorder of the intramitochondrial redox state [2]. These situations may be present in inborn metabolic diseases that aå ect Material and methods Principle of the method The two assays are based on end-point reactions catalysed by b-hydroxybutyrat e dehydrogenas e at 37 8C and diå erent pH conditions. The generation or consumption of reduced nicotinamide ademine dinucleotide (NADH) is measured by changes in absorbance at 340 nm: b-hydroxybutyrate ‡ NAD¡ Á ¡ ¡ ¡ ¡ ¡ ! ¡¡¡¡¡¡ dehydrogenase b¡hydroxybutyrate acetoacetate ‡ NADH ¡ ‡ H‡ To complete the b-hydroxybutyrat e reaction a pH of 9.5 is necessary while the acetoacetate assay requires a pH of 7. Journal of Automated Methods & Management in Chemistry ISSN 1463± 9246 print/ISSN 1464± 5068 online # 2001 Taylor & Francis Ltd http://www.tandf.co.uk/journals Table 1. Settings for ­ -hydroxybutyrate determination by the dimension R £ L analyser. Reagent and sample delivery Setting Delivery time (s) Volume delivery (ml) Chase delivery (ml) Mix First reagent (R1) (NAD 168 mM) 760.0 20.0 0.0 None Second reagent (R2) (Tris 0.1M pH 9) 65.3 245.0 20.0 Moderate Third reagent (R3) (HBDH 15 U ml¡1 ) 125.3 12.0 20.0 Moderate Sample (S1) 0.0 60 0.0 None Photometric readings and calculation Mode Standard curve Measuring ® lter First ® lter Secondary ® lter Time of photometric readings P1 P2 Calculation mode Dilution Absorbance Logit 340 nm 700 nm 110 s 410 s Endpoint C ˆ A £ …¡0:915†‡ B £ …1:0†Reagents and work solutions b-Hydroxybutyrate . Reagent 1: 168 mmol L¡1 : nicotinamide adenine dinucleotide (NAD) (Roche catalogue 127841) in distilled water. Stable for 6 months when frozen at ¡20 8C in aliquots. . Reagent 2: 0.1 mol L¡1 tris buå er (tris(hydroxymethyl)-aminomethane , Merck catatalogue 8382) adjusted to pH 9.5 with HCl. . Reagent 3: b-hydroxybutyrat e dehydrogenas e (EC1.1.1.30) (HBDH Roche catalogue 127841; speci® c activity: 3 U mg¡1 (25 8C). Stable at 4 8C. . b-hydroxybutyrat e standards to calibrate the method: d,l b-hydroxybutyri c acid, sodium salt (Sigma H6501). Prepare 0, 50, 250, 500 and 1250 mmol L¡1 solutions in distilled water. Stable for 6 months when frozen at ¡20 8C in aliquots. . Reagent 1: 4 mmol L¡1 NADH (Roche catalogue 128023) in distilled water. Stable for 6 months when frozen at ¡20 8C in aliquots. . Reagent 2: 0.1 mol L¡1 tris buå er (tris(hydroxymethyl)-aminomethane , Merck catalogue 8382) adjusted to pH 7. . Reagent 3: b-hydroxybutyrat e dehydrogenas e (EC1.1.1.30) (Roche catalogue 127841); speci® c activity 3 U mg¡1 (25 8C). Stable at 4 8C. . Acetoacetate standards to calibrate the method: acetoacetic acid salt (Sigma, catalogue A-8509). Prepare 0, 50, 100, 200 and 400 mmol L¡1 solutions in distilled water. Stable for 4 weeks when frozen at ¡20 8C in aliquots. Reagents for specimen preparation For deproteinized plasma samples: 1 mol L¡1 perchloric acid (Merck catalogue 519) and 0.7 mol L¡1 tripotassium phosphate (Merck catalogue 5102). For plasma samples: ¯ uoride/EDTA (Roche catalogue 243710). Automated assay The settings used on the Dimension R £ L analyser are listed in tables 1 and 2. Calibration method Calibration was with b-hydroxybutyrat e and acetoacetate standards described in Reagents and work solutions above. b-Hydroxybutyrat e was calibrated following a logarithmic reaction and acetoacetat e a linear reaction. Subjects Reference values were calculated from 60 samples obtained from apparently normal children, and were sent to our laboratory for analytical control before minor surgical interventions were carried out on the patients. Blood samples were obtained after 12 hours of fasting. The age range of the children was 1 month to 14 years. The specimens were assayed the same day as the blood samples were obtained. 20 of these values were used to study the comparison between plasma and deproteinized plasma samples. 20 apparently normal subjects (age range 20± 60 years), 20 patients with diabetic ketosis and another 20 patients with metabolic disorders were also included in the study. Specimens The blood specimens (1 ml) were added immediately to tubes containing 1 ml cold 1 mol L¡1 perchloric acid. The samples were mixed and centrifuged (3000 £ g for 10 minutes). The deproteinized supernatants were stored at ¡20 8C until analysis. The supernatants were adjusted to Acetoacetate Table 2. Settings for acetoacetate determination by the Dimension R £ L analyser. Reagent and sample delivery Setting Delivery time (s) Volume delivery (ml) Chase delivery (ml) Mix First reagent (R1) (NAH 4 mM) 760.0 16.0 0.0 None Second reagent (R2) (Tris 0.1 M pH 7) 65.3 95.0 20.0 Moderate Third reagent (R3) (HBDH 15 U ml¡1 ) 125.3 5.0 20.0 Moderate Sample (S1) 0.0 95 0.0 None Photometric readings and calculation Mode Standard curve Measuring ® lter First ® lter Secondary ® lter Time of photometric readings P1 P2 Calculation mode Dilution Absorbance linear 340 nm 700 nm 110 s 560 s Endpoint C ˆ A £ …¡0:900†‡ B £ …1:0†pH 7 with 0.7 mol L¡1 tripotassium phosphate, stored for 15 minutes at 4 8C and then centrifuged. The alkalinized supernatants were used to measure the ketone bodies. To obtain plasma samples 1 ml blood was added to tubes containing 1 drop of ¯ uoride/EDTA and then mixed. The supernatants obtained after centrifuging at 3000 £ g for 10 minutes were stored at ¡20 8C and used to measure the ketone bodies. Quality control b-Hydroxbutyrat e and acetoacetate standards, at two levels, were always assayed with patient samples ® rst at one level and at the end of the batch at the other level. The assay was considered to be correct if the standard values were within §10% of the assigned value. Evaluation of the method The analytical interval and the detection limit of the methods were evaluated following the directions of the Socite¨ Franmaise de Biologie Clinique [17]. To calculate the analytical interval the following standard aqueous solutions were used: 2500, 2000, 1250, 500, 250, 100, 25, 0.1 mmol L¡1 of d,l-b-hydroxybutyri c acid, sodium salt, and 600, 500, 250, 100, 50, 25, 10, 5, 0.1 mmol L¡1 acetoacetic acid salt. The detection limit (Ld ) was established following the processing of 10 specimens of distilled water. With the mean (md ) and the standard deviation (SD) the detection limit for an ¬ and ­ risk of 5% (K ˆ 5:185) was calculated (Ld ˆ md ‡ K SD) [17]. The recommendations of the European Committee for Clinical Laboratory Standards (ECCLS) were followed for the study of the imprecision and inaccuracy of the method [18]. 50,100 and 200 mmol L¡1 hydroxybutyrate and acetoacetate standard aqueous solutions were used. 430, 700 and 1000 mmol L¡1 hydroxybutyrat e and 100, 200 and 400 mol L¡1 acetoacetate were the standard aqueous solutions used. The dilution eå ect was corrected by adding the same volume of saline solution to unaltered samples. The reference values of the methods were obtained following the recommendations of the Panel of Experts of the International Federation of Clinical Chemistry on reference values [19]. Sample evaluation : deproteinized plasma or not b-Hydroxybutyrat e and acetoacetate were assayed in 80 patients in replicate using as samples plasma obtained directly with ¯ uoride/EDTA and deproteinized plasma with perchloric acid. Comparison studies were performed among the results from the two diå erent samples. Statistical methods The mean, standard deviation and coeæ cient of variation for studying the accuracy, imprecision and detection limit were obtained. The Student’ s t test was applied to compare the types of sample. Regression analyses were applied to obtain the analytical interval. The Mann± Whitney test was applied to establish the statistical diå erences between groups. To calculate the reference values of the method, the 2.5, 50 and 97.5 percentiles were used. Results Detection limit and analytical interval of methods The detection limit established was 12 mmol L¡1 for bhydroxybutyrat e and 6 mmol L¡1 for acetoacetate. The analytical interval of the methods ranged from 12 to 1300 mmol L¡1 for b-hydroxybutyrat e and from 10 to 450 mmol L¡1 for acetoacetate . Figure 1 shows the slope To determine the analytical recovery of the methods, increasing quantities of b-hydroxybutyrat e or acetoacetate were added to diå erent aliquots of the pool of sera. Figure 1. Analytical interval for ­ -hydroxybutyrate. (ö), Reference line y ˆ bx (b ˆ 1); (- - - - -) regression line (y ˆ 1:023x ¡ 2:349); (>) mean and two standard deviations of each point. The mean values of the points found and their two ? standard deviations coincide with the reference line from 12 to 1300 mmol L¡1 . of linear regression of the least squares (y ˆ 1:023 £ ¡2:349; r ˆ 0:989) of the reference hydroxybutyrate standards processed in triplicate over 3 consecutive days, and the values found. The linear regression for the acetoacetate standard was y ˆ 1:020 £ ¡3:01 ; r ˆ 0:976) (® gure 2). tions of b-hydroxybutyrat e (t ˆ ¡0:287; p ˆ 0:775) and acetoacetate (t ˆ ¡0:430, p ˆ 0:669) using deproteinized plasma with perchloric and non-deproteinize d plasma (¯ uoride/EDTA) (table 7). Discussion The determination of levels of blood ketone bodies is an infrequent type of analysis in clinical biochemistry laboratories. There are several reasons for this. Firstly, clinical interpretation of these results is diæ cult because of intraindividual variations, thereby making it diæ cult to establish reference values. Secondly, there are many physiological situations in which ketosis may be produced, thus to achieve a correct diagnosis of hyperketosis, other metabolites, such as glucose, lactate, pyruvate or amino acids, should be measured simultaneously. Therefore, use of blood ketone bodies is restricted to some concrete and diæ cult diagnoses. An example is the investigation of inborn errors of intermediary metabolism, especially aå ecting energetic homeostasi s (defects of the mitochondrial respiratory chain, b-oxidation, ketogenesis and ketolysis). Since the incidence of these diseases is low, few manufacturers have been motivated to elaborate commercial kits for measuring these metabolites and even less to implement them in an automatic Imprecision and inaccuracy. Table 3 demonstrates the within-run and between-run coeæ cients of variation of the aqueous standards of b-hydroxybutyrat e and acetoacetate at three concentration levels, as well as those of the serum specimen. The percentages of inaccuracy with respect to the theoretical value (table 4) did not exceed 10%. Analytical recovery study. Analytical recovery ranged from 97 to 104% for hydroxybutyrat e and 98 to 103% for acetoacetate (table 5). Reference values. Table 6 contains the reference values for the studied population which was divided into two groups (1 month to 7 years and 7 to 14 years). Statistical diå erences between the two groups were found for the b-hydroxybutyrat e (p ˆ 0:032) and acetoacetat e (p ˆ 0:041) results, but no diå erences were found for the b-hydroxybutyrate /acetoacetate ratio (p ˆ 0:200). Comparison between plasma and deproteinized plasma samples. No statistical diå erences were found for the concentra72 Figure 2. Analytical interval for acetoacetate. (ö), Reference line y ˆ bx (b ˆ 1); (- - - - -) regression line (y ˆ 1:020x ¡ 3:01); (>) mean and two standard deviations of each point. The mean values of the points found and their two standard deviations coincide with ? the reference line from 10 to 450 mmol L¡1 . Table 3. Imprecision of the methods. b-Hydroxybutyrate Concentration level Aqueous b-hydroxybutyrate solution (50 mmol L¡1 ) Aqueous b-hydroxybutyrate solution (100 mmol L¡1 ) Aqueous b-hydroxybutyrate solution (200 mmol L¡1 ) Serum pool (170 mmol L¡1 ) Deproteinized plasma pool (110 mmol L¡1 ) Acetoacetate Concentration level Aqueous acetoacetate solution (50 mmol L¡1 ) Aqueous acetoacetate solution (100 mmol L¡1 ) Aqueous acetoacetate solution (200 mmol L¡1 ) Serum pool (96 mmol L¡1 ) Deproteinized plasma pool (141 mmol L¡1 ) N 20 20 20 20 20 Within-run CV(%) 5 4 3 4.5 4.9 Between-run (CV%) 9.5 9.1 7.3 Ð Ð N 20 20 20 20 20 Within-run CV(%) 6 5 4 5.1 5.2 Between-run (CV%) 9.5 9.1 7.3 Ð Ð analyser. The manual practice of these assays does not favour their use since the preparation of the reagents and the assay itself are laborious, time-consuming, require high reagent and sample volumes, and give elevated imprecisions [8, 9]. Similar to several previous works [10± 14], we have automated a spectrometric method [16] to measure ketone bodies in a Dimension R £ L analyser, which is available 24 hours a day in the laboratory. With this adaptation we have improved notably the analytical reliability of our results in addition to saving time, and reagent and sample volume. This is an important point to take into account since most samples are of paediatric origin. Moreover, complementary analyses must be performed to achieve the diagnosis Table 4. Inaccuracy of methods. b-Hydroxybutyrate Within-run Theoretica concentrationl (mmol L¡1 ) 50 100 200 Acetoacetate Within-run Theoretical concentration (mmol L¡1 ) 50 100 200 Mean found concentration (mmol L¡1 ) 48 98 195 Between-run Mean found concentration (mmol L¡1 ) 53 92 215 Mean found concentration (mmol L¡1 ) 53 101 198 Between-run Mean found concentration (mmol L¡1 ) 47 105 186 N 20 20 20 Inaccuracy (%) 6 1 71 Inaccuracy (%) 76 5 77 N 20 20 20 Inaccuracy (%) 74 72 72.5 Inaccuracy (%) 6 78.0 7.5 Table 5. Recovery study. b-Hydroxybutyrate b-Hydroxybutyrate added (mmol L¡1 ) 430 700 1000 Theoretical b-Hydroxybutyrate concentration (mmol L¡1 ) 630 900 1200 Found b-Hydroxybutyrate concentration (mmol L¡1 ) 655 873 1284 Serum pool (mmol L¡1 ) 200 200 200 Acetoacetate Recovery (%) 104 97 104 Serum pool (mmol L¡1 ) 80 80 80 Acetoacetate added (mmol L¡1 ) 100 200 400 Theoretical acetoacetate concentration (mmol L¡1 ) 180 280 480 Found acetoacetate concentration (mmol L¡1 ) 176 288 475 Recovery (%) 98 103 99 Table 6. Reference values. 0± 7 years (n ˆ 30) b-Hydroybutyrate (mmol L¡1 ) Range (p2:5 ; p97:5 ) Mean value (p50 ) Acetoacetate (mmol L¡1 ) Range (p2:5 ; p97:5 ) Mean value (p50†­ -Hydroybutyrate/acetoacetate Range (p2:5 ; p97:5 ) Mean value (p50 ) 74 20± 700 60 10± 200 45 0.04± 4.0 1.3 7± 14 years (n ˆ 30) 20± 500 40 10± 140 31 0.04± 3.5 1.1 Table 7. Comparison between deproteinized and non-deproteinized plasma as samples ­ -Hydroxybutyrate Mean value (mmol L¡1 ) 402.46 400.46 Standard deviation (mmol L¡1 ) 394.33 377.58 Range (mmol L¡1 ) 10± 1290 10± 1220 70.287 0.775 0.991 Pearson coeæ cient r Regression line y ˆ 1:035x ¡ 0:99 Sample Student’ s t Deproteinized 80 plasma (x) Plasma 80 (¯ uoride/EDTA) non-deproteinized ( y) Acetoacetate Sample Deproteinized plasma (x) Plasma (¯ uoride/EDTA) non-deproteinized (y) n 80 80 Mean value (mmol L¡1 ) 154.45 153.26 Standard deviation (mmol L¡1 ) 134.97 130.02 Range (mmol L¡1 ) 10± 450 Student’ s t 70.430 p 0.669 Pearson coeæ cient r 0.988 Regression line y ˆ 1:025x ¡ 1:637 10± 430 and they can be processed simultaneously in the same analyser. Another diæ culty, from the technical point of view, in analysing ketone bodies derives from sample collection. Acetoacetate is an unstable metabolite [16] thus it is recommended that the blood be collected immediately after its withdrawal in an acid medium to be deproteinized as well as the samples be maintained in ice until processing. Other authors [13, 16], who usually determine lactate, pyruvate and ketone bodies in the same sample, recommend the use of deproteinized plasma with perchloric acid. We also perform our assays in this type of sample. However, we have observed that the results using plasma collected directly in ¯ uoride/EDTA are similar to those obtained from deproteinized plasma with perchloric acid. On the other hand, statistically signi® cant diå erences were found (n ˆ 80, t ˆ 8:08, p < 0:001) between using deproteinized plasma ( y) and non deproteinized plasma (¯ uoride/EDTA) (x) in the quanti® cation of pyruvate (y ˆ 1:74x ‡ 4:62; r ˆ 0:599) (data not included in the study). We did not observe diå erences in the lactate values using these two types of sample (n ˆ 80, t ˆ 0:118, p ˆ 0:779). Thus, if the four metabolites are to be measured in the same sample it is necessary to use deproteinized plasma in an acid medium after extraction because the pyruvate values may be incorrect. However, the ketone bodies may be evaluated directly in a serum sample which has been withdrawn with ¯ uoride/EDTA with the aim of measuring its lactate for example. There are several advantages to working directly with non-deproteinized plasma. The possible dilution error (which falsi® es the absolute value of the metabolites although not their ratios) is minimized. Additionally, the analytical procedure is reduced by 30 minutes. The present adaptation, especially using nondeproteinized plasma, simpli® es the anaytical procedure and, although the preparation of reagents is somewhat laborious, the fact that they may be stored frozen, allows the assay to be performed with relative ease in emergency situations. We have established our reference values for a population under the age of 14 years. Signi® cant diå erences were found in two age groups for the two metabolites, but not for their ratios. These results have been reported by Artuch et al. [13]. Similar to other reports [13, 20], our reference values present a wide range of values. Many intraindividual variations may be due to the nutritional state of the patient. In summary, this adaptation facilitates the measurement of sanguineous ketone bodies and provides a rapid and reliable method with low sample consumption and which may to be applied as a routine technique in an emergency laboratory. The main application of this method is to contribute to the diagnosis of mitochondrial diseases both in the ® rst orientation as well as in subsequent provocative tests [6, 7]. References 1. Guthrie, J. P. and Jordan, F., 1972, Amine-catalyzed decarboxylation of acetoacetic acid. The rate constant for decarboxylation of beta-immino acid. J. Am. Chem. Soc., 94, 9136. 2. Robinson, B. H., 1989, Lactic acidemia. In: C. R. Scriver, A. L. Beaudet, Ws. Sly and D. Valle (eds) The Metabolic Basis of Inherited Disease (New York: McGraw-Hill), p. 869. 3. Roth, K. S., 1991, Inborn errors of metabolism: the essentials of clinical diagnosis. Clin. Pediatr., 30, 183. 4. Munnich, A., RÎtig, A., Chretien, D., Saudubray, J. M., Cormier, V. and Rustin, P., 1996, Clinical presentation and laboratory investigations in respiratory chain de® ciency. Eur. J. Pediatr., 155, 262. 5. Poggi, F., Rabier, D., Vassault, A., Charpentier, C., Kamoun, P. and Saudubray, J. M., 1994, Protocole d’ investigations metaboliques dans les maladies hereditaries du metabolisme. Arch. ¨ ¨ ¨ Pediatr., 1, 667. ¨ © 6. Galan, A., Coll, J., Padros, A., Arambarri, M. and Pintos, G., 1999, Estrategia diagnostica de las enfermedades mitocondriales. © Rev. Neurol., 29, 52. 7. Bonnefont, J. P., Specola, N. B., Vassault, A., Lombes, A., Ogier, H., de Klerk, J. B. C. et al., 1990, The Fasting test in paediatrics: application to the diagnosis of pathological hypo and hyperketonic states. Eur. J. Pediatr., 150, 80. Williamson, D. H. and Mellanby, J., 1974, D-3-Hydroxybutyrate. In: H. U. Bergmeyer (ed.) Methods of Enzymatic Analysis (New York: Academic Press), p. 1836. Mellanby, J. and Williamson, D. H., 1974, Acetoacetate. In: H. U. Bergmeyer (ed.) Methods of Enzymatic Analysis (New York: Academic Press), p. 1840 Nuwayhid, N. F., Johnson, G. F. and Feld, R. D., 1989, Multipoint kinetic method for simultaneously measuring the combined concentrations of acetoacetate-b-hydroxybutyrate and lactate-pyruvate. Clin. Chem., 35, 1526. Hansen, J. L. and Freier, E. F., 1978, Direct assays of lactate, pyruvate, b-hydroxybutyrate and acetoacetate with a centrifugal analyzer. Clin. Chem., 24, 475. Li, P. K., Lee, J. T., MacGillivray, M. H., Schaefer, P. A. and Siegel, J. H., 1980, Direct, ® xed-time kinetic assays for b-hydroxybutyrate and acetoacetate with a centrifugal analyzer or a computer-backed spectrophotometer. Clin. Chem., 26, 1713. ¨ Artuch, R., Vilaseca, M. A, Farre, C. and Ramon, F., 1995, Determination of lactate, pyruvate, b-hydroxybutyrate and acetoacetate with a centrifugal analyser. Eur. J. Clin. Chem. Clin. Biochem., 33, 529. 14. Uno, S., Takehiro, O., Tabata, R. and Ozawa, K., 1995, Enzymatic method for determining ketone body ratio arterial blood. Clin. Chem., 41, 1745. 15. Mitchell, G. A., Kassovska-Bratinova, S., Boukaftane, Y., Robert, M.-F., Wang, S. P., Ashmarina, L., Lambert, M., Lapierre, P. and Potier, E., 1995, Medical aspects of ketone body metabolism. Clin. Invest. Med., 18, 193. 16. Vassault, A., Bonnefont, J. P., Specola, N. and Saudubray, J. M., 1991, Lactate, Pyruvate and Ketone Bodies. Techniques in Diagnostic Human Biochemical Genetics: A Laboratory Manual (New York: Wiley-Liss) p. 285. ¨ 17. Societe Franc aise de Biologie Clinique, 1986, Commission ° ` Validation de techniques’ . Protocole de validation de techniques. Ann. Biol. Clin., 44, 686. 18. European Committee for Clinical Laboratory Standards, 1986, Guidelines for the evaluation of analyzers in clinical chemistry. ECCLS Document, 3(2). 19. International Federation of Clinical Chemistry, 1987, Approved recommendation (1987) on the theory of reference values. Part 5. Statistical treatment of collected reference values. Determinations of reference limits. Clin. Chem. Acta, S13-S32, 170. 20. Lamers, K. J. B., Doesburg, W. H., Gabreels, F. J. M., Romsom, « A. C., Renier, W. O., Wevers, R. A. and Lemmens, W. A., 1985, Reference values of blood components related to fuel metabolism in children after an overnight fast. Clin. Chim. Acta, 145, 17.

Journal

Journal of Automated Methods and Management in ChemistryHindawi Publishing Corporation

Published: Dec 28, 2014

There are no references for this article.