CRC, University of Tasmania, Private Bag 80, Hobart, Tasmania 7001, Australia of Earth, Ocean and Environmental Sciences, Plymouth Environmental Research Centre, University of Plymouth, Plymouth PL4 8AA, UK Received 23 September 2004; Accepted 23 September 2004 A ï¬ow-injection (FI)-based instrument under LabVIEW control for monitoring iron in marine waters is described. The instrument incorporates a miniature, low-power photomultiplier tube (PMT), and a number of microelectric and solenoid actuated valves and peristaltic pumps. The software allows full control of all ï¬ow injection components and processing of the data from the PMT. The optimised system is capable of 20 injections per hour, including preconcentration and wash steps. The detection limit (3 sd of the blank) is 21 pM at sea and the linear range is 21â2000 pM with a 60-second sample load time. Typical precision between replicate FI peaks is 5.9 ± 3.2% (n = 4) over the linear range. INTRODUCTION Iron is an important parameter to determine in seawater because of its role in photosynthetic processes [1], ocean productivity [2], and hence global carbon cycling [3]. Openocean concentrations of dissolved iron(II+III) are in the range of 50â700 pM [4] and are typically depleted in surface waters and elevated at depth. Iron in seawater can be determined in the laboratory using isotope dilution HR-ICP-MS after coprecipitation [5] or HR-ICP-MS after solid-phase extraction [6], GFAAS after solvent extraction [7], ï¬ow injection (FI) with chemiluminescence (CL) [8, 9], spectrophotometric [10] detection or cathodic stripping voltammetry [11]. Current oceanographic studies however require the determination of iron at sea in real time and this necessitates the use of portable, shipboard instrumentation, for which FI techniques are ideally suited. This paper describes the design and performance characteristics of a fully automated and portable FI instrument with CL detection for real-time monitoring of iron at sea. The system incorporates a low power (5 V) photomultiplier tube (PMT), an immobilised chelating resin for analyte preconcentration and luminol chemistry for detection. Iron(II) can be determined directly by its enhancing Correspondence and reprint requests to Paul J. Worsfold, School of Earth, Ocean and Environmental Sciences, Plymouth Environmental Research Centre, University of Plymouth, Plymouth PL4 8AA, UK; E-mail: pworsfold@plymouth.ac.uk. eï¬ect on the luminol reaction and âtotalâ iron(II+III) can be determined after acidiï¬cation and sample reduction steps. A graphical programming environment (LabVIEW, http://sine.ni.com/labview) facilitates the design of a virtual instrument with a fully ï¬exible user interface for instrument control and data acquisition. 2. EXPERIMENTAL 2.1. Reagents and standards All chemicals were obtained from Merck BDH (Crown Scientiï¬c, Kingston, Australia), unless otherwise stated. Labware was cleaned by soaking in successive baths of hot 5% (v/v) micro-detergent (Decon) for 24 hours, 6 M HCl (AnalaR) for 1 week, and 2 M HNO3 (AnalaR) for 1 week, with thorough rinses using doubly deionised water (DIW, 18.2 M⦠cmâ1 ) between each step. Sample handling was carried out in a class-100 laminar ï¬ow hood. High purity quartz distilled (Q-) HCl, HNO3 , ammonia, and acetic acid were obtained from Seastar (Baseline grade, Sidney, BC, Canada). Iron(II) standards were prepared daily in 0.1 M Q-HCl from Fe(NH4 )2 (SO4 )2 ·6H2 O. Luminol (Sigma, Perth, Australia) (1 à 10â5 M) was prepared in 0.1 M Na2 CO3 by dilution of a 0.01 M stock, adjusted to pH 12.2 with 2 M NaOH, and passed through a Chelex-100 (Sigma) chelating resin column just prior to use. Ammonium acetate sample buï¬er (0.4 M) was prepared from a 2 M stock and adjusted to pH 5.5 with Q-acetic acid. An iron(III) reducing agent of 100 µM Na2 SO3 (extra pure) was prepared from a 0.4 M Luminol HCl eluent Filtered seawater Pump A 10-way selection Valve Standards Sample Waste 1 2 6 3 5 4 Injection valve 1 âYâ-piece Ammonium acetate buï¬er Pump B 8-HQ clean-up column 250 µL mixing coil 2 mL holding coil LISW carrier DIW wash HCl wash Switching valve 1 Pump C Switching valve 2 5 1 2 3 4 Integrator, ampliï¬er and ï¬lter Data acquisition PMT Flow cell 8-HQ preconcentration column 6 Waste Injection valve 2 Detector housing Waste Figure 1: FI-CL manifold for the determination of iron in seawater. stock pre-cleaned through an 8-HQ column. The eluent was 0.09 M Q-HCl and the strong acid wash (used only periodically to clean the manifold) was 0.6 M Q-HCl. Low iron seawater (LISW) obtained from the open ocean was used as the carrier stream to transport the sample from the holding loop to the preconcentration column. 2.2. FI manifold Figure 1 shows the automated FI-CL manifold. Pumps A, B, and C were 4-channel peristaltic pumps (Gilson Minipuls 3, Anachem, Luton, UK). Injection valves 1 and 2 were 1/4-28, 6port, low-pressure valves (Cheminert C22, Valco, Houston, USA) with two position microelectronic actuation. A 1/4-28, 10-port, low-pressure selection valve (Cheminert C25, Valco, Houston, USA) with multiposition micro-electronic actuation was used to switch between standards and the sample. Switching valves were PTFE 3-way, two-position solenoids (EW-01367-72, Cole-Parmer, Hanwell, UK). Pumps and valves were operated at 5 V dc (TTL) and switches at 12 V dc. A power saver relay reduced the solenoid input voltage to 8 V dc when energising for extended periods. The detection system was a coiled transparent PVC ï¬ow cell (1.0 mm i.d.) mounted on the side window of a 5 V dc photon counting head (model H6240-01, Hamamatsu Photonics, Welwyn Garden City, UK). Detector speciï¬cations are given in Table 1. The TTL pulse train from the photon counting head was integrated, ampliï¬ed, and ï¬ltered prior to data acquisition (Figure 2). Flow lines, ï¬ttings, and connectors were cleaned for 1 day with 0.6 M Q-HCl and DIW prior to use. Manifold tubing was 0.75 mm i.d. PTFE (Fisher Scientiï¬c, Loughborough, UK). Peristaltic pump tubing was ï¬ow-rated PVC (Elkay, Basingstoke, UK). Preconcentration, matrix elimination, and sample buï¬er clean-up was performed in line using 8-hydroxyquinoline (8HQ) immobilised on a vinyl copolymer resin packed into 50 µL micro-columns [8]. Clean surface seawater was supplied to the FI manifold at sea using a high-volume peristaltic pump (7591-00, Cole Palmer Instrument Co.) connected to a torpedo-shaped ï¬sh, Flow Injection-Chemiluminescence for Iron in Seawater Table 1: Speciï¬cations of miniature photon counting head. Maximum ratings Parameter Supply voltage Operating temperature range Storage temperature range Speciï¬cations at 25⦠C Parameter Eï¬ective area Spectral response Typical dark count Maximum dark count Counting linearity Pulse pair resolution Output pulse width Output logic Input voltage Input current at 2.5 Mcps output Main control unit Mains input Mains ï¬lter and switch 240 VAC +12 V linear power supply Value +6 +5 to 40 â20 to 50 H6240-01 4 à 20 185 to 850 80 200 2.5 35 30 TTL, positive +5 Maximum 80 Unit V dc ⦠C ⦠C Unit mm2 nm cps cps Mcps ns ns V dc mA PMT interface +8 V regulator +5 V regulator +12 VDC 240 VDC 4 TTL lines +8 VDC +5 VDC 240s VAC mains relays 4 outputs PA0-PA3 +5 VDC PA4-PA7 PB0-PB7 PC0-PC7 PA0-PA7 PCMCIA card PCMCIA (DAQCard-DIO-24) PB0-PB7 bus PC0-PC7 +12 VDC +8 VDC 4 TTL lines 8 TTL lines 8 TTL lines 5 VDC open drain outputs (TTL control) 12/8 VDC open drain outputs (solenoids) PMT power switch PMT 2 gain selector (2-4 decoder) PMT 1 gain selector (2-4 decoder) 12 outputs Power saver relay +5 VDC DO4-DO5 DO4-DO5 8 outputs DO6 +5 VDC (PMT2) +5 VDC (PMT1) Ã100 Ã1000 Ã2000 Ã5000 Ã100 Ã1000 Ã2000 Ã5000 2 TTL lines 2 TTL lines 2 TTL lines PCMCIA PCMCIA card bus (DAQCard-700) DO0DO6 (DO7 is spare) DO0-DO1 Integrator Switched gain ampliï¬er Lowpass ï¬lter Analog output Pulse output +5 V PMT2 (ACH0) PMT1 (ACH1) ACH2-ACH15 ACH2-ACH15 Figure 2: Block diagram of the automated FI-CL instrument incorporating the main control unit and PMT interface (integrator, ampliï¬er, and ï¬lter are shown on PMT 1 only). Table 2: Timing sequence for one analytical cycle. The pump and valve numbers refer to those shown in Figure 1. Elapsed time (s) A 0 60 100 160 180 a Injection Pumps B C On On Oï¬ On Oï¬ On On Oï¬ Oï¬ On Oï¬ On Cycle back to line 1 Injection valvesa 1 On Oï¬ Oï¬ Oï¬ 2 Oï¬ Oï¬ On Oï¬ Switching valves 1 On Oï¬ Oï¬ Oï¬ 2b Oï¬ Oï¬ Oï¬ Oï¬ 10-way selection valve positionc 1 1 1 1 Operation Load Wash Elute Rinse valves: Oï¬=load sample and On=elute sample. valve 2 is On only when an acid wash solution is passed over the 8HQ column. c 10-way selection valve remains in position 1 (sample port). For calibration this valve switches to positions 2â10 (depending on the number of standards to be run). b Switching which was towed alongside the research vessel at a depth of 1â2 m below the surface, 5 m from the shipâs hull. For water column samples, seawater was collected in acid-washed polycarbonate samplers suspended oï¬ Kevlar hydroline, following standard trace metal sampling methods [12]. Seawater was ï¬ltered in-line through a 0.4 µm cellulose acetate membrane contained in a polypropylene cartridge unit (Sartorius, Epsom, UK). Samples for iron(II) determinations were fed directly to the analyser at ambient seawater pH. Samples for iron(II+III) were acidiï¬ed to pH â¼ 2 with QHCl and reduced oï¬-line using 100 µM Na2 SO3 (4 h) prior to analysis. One complete analytical cycle, consisting of sample load, DIW rinse and elution, took 3 minutes. The operation, the state of each component (on or oï¬ for switching and injection valves; position for selection valve), and associated timing parameters during each cycle are shown in Table 2. 2.3. Interface Instrument control was achieved via a DAQCard-DIO-24 card (National Instruments Corp., Newbury, UK) with 24 digital input/output TTL lines, and signal acquisition was via a DAQCard-700, with 16-channel, 12-bit A/D conversion. This card was also used for changing PMT gain. Virtual instrument (VI) software (Ruthern Instruments Ltd., Bodmin, UK) was written in LabVIEW version 5.1 (National Instruments Corp.). The interface had two units, one for controlling pumps and valves and one for the PMT and signal processing (Figure 2). The LabVIEW VI front panel contained ready-to-use switches, buttons, controls, and graphical displays of detector readings (Figure 3). Each element in the front panel was connected via the wiring diagram (Figure 4), which included functions for signal processing, timing of operations, and ï¬le management. 3. RESULTS AND DISCUSSION Figure 3: LabVIEW graphical user front panel for the automated virtual instrument. The PMT data and Data history displays show the unit in calibration mode. which allowed the sensitivity to be adjusted to suit the variable concentrations of iron found in seawater. The eï¬ect of each of these settings on the CL background emission, background noise, and analyte signal for a 2.0 nM iron(II) standard was investigated in direct injection mode (i.e., no preconcentration column), and the results are shown in Figure 5. The CL background noise (peak-to-peak) showed no change with gain setting, but both the CL emission for iron and the background CL emission increased linearly with respect to PMT gain. The maximum signal-to-noise ratio was obtained at the highest gain setting (Ã5000), which was therefore most suitable for iron-depleted open-ocean measurements. For environments with higher iron concentrations (such as coastal and estuarine waters), a lower gain setting can be used to provide an expanded linear range. 3.2. Analytical ï¬gures of merit 3.1. Detector performance The PMT interface contained a 4-position switched gain ampliï¬er (Figure 2). This provided settings of Ã100, Ã1000, Ã2000, and Ã5000, selectable by the control VI software, Figure 6 shows a typical FI trace for the blank, sample, and standard additions of 0.2â1.0 nM iron(II) spikes to a seawater sample. The mean repeatability and standard deviation for 4 replicates over this range was 5.9 ± 3.2%. The standard addition plot showed excellent linearity (R2 = 0.9979) over this range. The iron(II) blank was typically 24±7 pM (n = 4), Flow Injection-Chemiluminescence for Iron in Seawater Figure 4: Wiring diagram showing the graphical code for instrument control and data acquisition. This code drives the functions shown on the front panel in Figure 3. 1.0 0.9 CL emission (arbitrary units) 0.8 12 0.6 0.5 0.4 0.3 4 0.2 0.1 0.0 0 1000 2000 3000 PMT gain 4000 5000 2 0 10 8 6 Signal-to-noise ratio 0.7 16 14 Signal-to-noise ratio Fe signal (2.0 nM std) CL background emission CL background peak-to-peak noise Figure 5: Eï¬ect of changing the PMT gain on the CL background emission, CL background peak-to-peak noise, analyte signal and signalto-noise ratio with the instrument in direct injection mode (no preconcentration). Error bars indicate ±1 sd. CL emission (arbitrary units) 6 5 4 3 2 1 0 0 25 50 75 Time (min) 100 125 Blank Sample 1.2 CL emission (V) 1.0 0.8 0.6 0.4 0.2 0.0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Fe(II) added (nM) y = 0.78 x + 0.18 R2 = 0.9979 +1.0 nM +0.8 nM +0.6 nM +0.4 nM +0.2 nM Figure 6: Shipboard calibration peaks and corresponding standard additions plot for iron over the range 0.2â1.0 nM. Error bars indicate ±1 sd. Dissolved (< 0.4 µm) Fe (nM) 0.2 0.4 0.6 resulting in a limit of detection of 21 pM (deï¬ned as three times the standard deviation of the blank). The major contributions to the blank signal were from iron impurities in the ammonium acetate buï¬er, DIW used for column washing, and (for iron(II+III) determinations) the acid and sulï¬te used for sample pretreatment [8]. 3.3. Field validation The optimised FI-CL instrument was trialled at a hydrocast station close to the Antarctic continent during a Southern Ocean expedition (November 2001) along the CLIVAR SR3 line (â¼ 141⦠E). Figure 7 shows the proï¬les of dissolved iron and temperature in the upper water column (25â300 m), illustrating the depletion of iron in the mixed layer (down to 100 m) due to biological uptake and its gradual regeneration at depth due to microbial decomposition of biogenic particles. Iron concentrations were between 220 and 360 pM at this location, consistent with literature data [13]. At sea, the instrument was totally reliable over 50 days of near continuous use for surface transects and depth proï¬ling, with no downtime in spite of the harsh conditions experienced in this environment. A report on the environmental signiï¬cance of the complete dataset from the 2001 CLIVAR SR3 expedition, obtained using this instrumentation, will be presented elsewhere. 4. CONCLUSIONS Depth (m) â1.0 0.0 1.0 2.0 Temperature (⦠C) Fe Temperature Figure 7: Typical depth proï¬les of dissolved iron and temperature in the upper water column of the Southern Ocean south of Australia at 141⦠E, 61⦠S. Error bars indicate ±1 sd. The automated virtual instrument uses ï¬ow injection with chemiluminescence detection for the determination of iron in seawater. This is an inexpensive, portable, and robust system suitable for shipboard deployment. The detection limit of 21 pM allows the determination of iron in all marine environments, including remote, iron-limited openocean regions. In addition, the use of oï¬-the-shelf components and industry standard graphical programming software makes the instrument readily adaptable to related analytes (e.g., cobalt [14], copper [15]) using well documented chemiluminescence reactions. This instrumentation should be easily transferable between laboratories, thus facilitating the harmonisation of analytical methods for the determination of iron in seawater, a current initiative of the Scientiï¬c Committee for Oceanic Research (SCOR) Working Group 109 (Biogeochemistry of Iron in Seawater) (http://www.jhu.edu/â¼scor/wg109front.htm). ACKNOWLEDGMENTS The authors thank John Wood (Ruthern Instruments) for constructing the main control unit and PMT interface. This work was funded by the EU programme MEMOSEA (Trace Metal Monitoring in Surface Marine Waters and Estuaries, MAS3-CT97-0143, NERC Grant NER/A/S/2003/00489) and an Australian Research Council IREX Fellowship to A. R. Bowie (X00106765). Flow Injection-Chemiluminescence for Iron in Seawater REFERENCES [1] R. J. Geider and J. La Roche, âThe role of iron in phytoplankton photosynthesis and the potential for iron-limitation of primary productivity in the sea,â Photosynthesis Research, vol. 39, pp. 275â301, 1994. [2] P. W. Boyd, A. J. Watson, C. S. Law, et al., âA mesoscale phytoplankton bloom in the polar southern ocean stimulated by iron fertilization,â Nature, vol. 407, no. 6805, pp. 695â702, 2000. [3] P. Falkowski, R. J. Scholes, E. Boyle, et al., âThe global carbon cycle: a test of our knowledge of earth as a system,â Science, vol. 290, no. 5490, pp. 291â296, 2000. [4] K. S. Johnson, R. M. Gordon, and K. H. Coale, âWhat controls dissolved iron concentrations in the world ocean?â Marine Chemistry, vol. 57, no. 3-4, pp. 137â161, 1997. [5] J. F. Wu and E. A. Boyle, âDetermination of iron in seawater by high-resolution isotope dilution inductively coupled plasma mass spectrometry after Mg(OH)2 coprecipitation,â Analytica Chimica Acta, vol. 367, no. 1â3, pp. 183â191, 1998. [6] M. L. Wells and K. W. Bruland, âAn improved method for rapid preconcentration and determination of bioactive trace metals in seawater using solid phase extraction and high resolution inductively coupled plasma mass spectrometry,â Marine Chemistry, vol. 63, no. 1-2, pp. 145â153, 1998. [7] K. W. Bruland, R. P. Franks, G. A. Knauer, and J. H. Martin, âSampling and analytical methods for the determination of copper, cadmium, zinc, and nickel at the nanogram per liter level in seawater,â Analytica Chimica Acta, vol. 105, pp. 233â 245, 1979. [8] A. R. Bowie, E. P. Achterberg, R. F. C. Mantoura, and P. J. Worsfold, âDetermination of sub-nanomolar levels of iron in seawater using ï¬ow injection with chemiluminescence detection,â Analytica Chimica Acta, vol. 361, no. 3, pp. 189â200, 1998. [9] J. T. M. de Jong, J. den Das, U. Bathmann, et al., âDissolved iron at subnanomolar levels in the southern ocean as determined by ship-board analysis,â Analytica Chimica Acta, vol. 377, no. 2-3, pp. 113â124, 1998. [10] C. I. Measures, J. Yuan, and J. A. Resing, âDetermination of iron in seawater by ï¬ow injection analysis using in-line preconcentration and spectrophotometric detection,â Marine Chemistry, vol. 50, no. 1â4, pp. 3â12, 1995. [11] H. Obata and C. M. G. van den Berg, âDetermination of picomolar levels of iron in seawater using catalytic cathodic stripping voltammetry,â Analytical Chemistry, vol. 73, no. 11, pp. 2522â2528, 2001. [12] P. N. Sedwick, P. R. Edwards, D. J. Mackey, F. B. Griï¬ths, and J. S. Parslow, âIron and manganese in surface waters of the Australian subantarctic region,â Deep-Sea Research I, vol. 44, no. 7, pp. 1239â1253, 1997. [13] H. J. W. de Baar and J. T. M de Jong, âDistributions, sources and sinks of iron in seawater,â in The Biogeochemistry of Iron in Seawater, D. R. Turner and K. A. Hunter, Eds., chapter 5, pp. 123â254, John Wiley & Sons, Chichester, UK, 2001. [14] V. Cannizzaro, A. R. Bowie, A. Sax, E. P. Achterberg, and P. J. Worsfold, âDetermination of cobalt and iron in estuarine and coastal waters using ï¬ow injection with chemiluminescence detection,â Analyst, vol. 125, pp. 51â57, 2000. [15] E. P. Achterberg, C. B. Braungardt, R. C. Sandford, and P. J. Worsfold, âUV digestion of seawater samples prior to the determination of copper using ï¬ow injection with chemiluminescence detection,â Analytica Chimica Acta, vol. 440, no. 1, pp. 27â36, 2001.
Journal of Automated Methods and Management in Chemistry – Hindawi Publishing Corporation
Published: Sep 3, 2014
You can share this free article with as many people as you like with the url below! We hope you enjoy this feature!
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.