Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Shielded metal arc welding of AISI 409M ferritic stainless steel: study on mechanical, intergranular corrosion properties and microstructure analysis

Shielded metal arc welding of AISI 409M ferritic stainless steel: study on mechanical,... The purpose of this study is on AISI 409 M ferritic stainless steel (FSS) which is developing a preferred choice for railway carriages, storage tanks and reactors in chemical plants. The intergranular corrosion behavior of welded SS 409 M has been studied in H2SO4 solution (0.5 M) with the addition of NH4SCN (0.01 M) with different heat input. As this study is very important in context of various chemical and petrochemical industries.Design/methodology/approachThe microstructure, mechanical properties and intergranular corrosion properties of AISI 409 M FSS using shielded metal arc welding were investigated. Shielded metal arc welding with different welding current values are used to change the heat input in the joints resulted in the microstructural variations. The microstructure of the welded steel was carefully inspected along the width of the heat-affected zone (HAZ) and the transverse-section of the thin plate.FindingsThe width of heat affected zone (3.1,4.2 and 5.8 mm) increases on increasing the welding heat input. Due to change in grain size (grain coarsening) as HAZ increased. From the microstructure, it was observed that the large grain growth which is dendritic and the structure become finer to increase in welding heat input. For lower heat input, the maximum microhardness value (388HV) was observed compared with medium (351 HV) and higher heat input (344 HV), which is caused by a rapid cooling rate and the depleted area of chromium (Cr) and nickel (Ni). The increase in weld heat input decreases tensile strength, i.e. 465 MPa, 440 MPa and 418 MPa for low, medium and high heat input, respectively. This is because of grain coarsening and chromium carbide precipitation in sensitized zone and wider HAZ. The degree of sensitization increases (27.04%, 31.86% and 36.08%) to increase welding heat input because of chromium carbide deposition at the grain boundaries. The results revealed that the higher degree of sensitization and the difference in intergranular corrosion behavior under high heat input are related to the grain growth in the HAZ and the weld zone.Originality/valueThe study is based on intergranular corrosion behavior of welded SS 409 M in H2SO4 solution (0.5 M) with the addition of NH4SCN (0.01 M) with different heat input which is rarely found in literature. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png World Journal of Engineering Emerald Publishing

Shielded metal arc welding of AISI 409M ferritic stainless steel: study on mechanical, intergranular corrosion properties and microstructure analysis

Loading next page...
 
/lp/emerald-publishing/shielded-metal-arc-welding-of-aisi-409m-ferritic-stainless-steel-study-tlZ2a3U8gW

References (27)

Publisher
Emerald Publishing
Copyright
© Emerald Publishing Limited
ISSN
1708-5284
DOI
10.1108/wje-03-2021-0146
Publisher site
See Article on Publisher Site

Abstract

The purpose of this study is on AISI 409 M ferritic stainless steel (FSS) which is developing a preferred choice for railway carriages, storage tanks and reactors in chemical plants. The intergranular corrosion behavior of welded SS 409 M has been studied in H2SO4 solution (0.5 M) with the addition of NH4SCN (0.01 M) with different heat input. As this study is very important in context of various chemical and petrochemical industries.Design/methodology/approachThe microstructure, mechanical properties and intergranular corrosion properties of AISI 409 M FSS using shielded metal arc welding were investigated. Shielded metal arc welding with different welding current values are used to change the heat input in the joints resulted in the microstructural variations. The microstructure of the welded steel was carefully inspected along the width of the heat-affected zone (HAZ) and the transverse-section of the thin plate.FindingsThe width of heat affected zone (3.1,4.2 and 5.8 mm) increases on increasing the welding heat input. Due to change in grain size (grain coarsening) as HAZ increased. From the microstructure, it was observed that the large grain growth which is dendritic and the structure become finer to increase in welding heat input. For lower heat input, the maximum microhardness value (388HV) was observed compared with medium (351 HV) and higher heat input (344 HV), which is caused by a rapid cooling rate and the depleted area of chromium (Cr) and nickel (Ni). The increase in weld heat input decreases tensile strength, i.e. 465 MPa, 440 MPa and 418 MPa for low, medium and high heat input, respectively. This is because of grain coarsening and chromium carbide precipitation in sensitized zone and wider HAZ. The degree of sensitization increases (27.04%, 31.86% and 36.08%) to increase welding heat input because of chromium carbide deposition at the grain boundaries. The results revealed that the higher degree of sensitization and the difference in intergranular corrosion behavior under high heat input are related to the grain growth in the HAZ and the weld zone.Originality/valueThe study is based on intergranular corrosion behavior of welded SS 409 M in H2SO4 solution (0.5 M) with the addition of NH4SCN (0.01 M) with different heat input which is rarely found in literature.

Journal

World Journal of EngineeringEmerald Publishing

Published: May 10, 2022

Keywords: Microstructure; Hardness; SS 409M; SMAW; Hardness; HAZ; Intergranular corrosion

There are no references for this article.