Parameter Identification for Ultrasound Shear Wave Elastography Simulation

Parameter Identification for Ultrasound Shear Wave Elastography Simulation AbstractElasticity of soft tissue is a valuable information to physicians in treatment and diagnosis of diseases. The elastic properties of tissue can be estimated with ultrasound (US) shear wave imaging (SWEI). In US-SWEI, a force push is applied inside the tissue and the resulting shear wave is detected by high-frequency imaging. The properties of the wave such as the shear wave velocity can be mapped to tissue elasticity. Commonly, wave features are extracted by tracking the peak of the shear wave, estimating the phase velocity or with machine learning methods. To tune and test these methods, often simulation data is employed since material properties and excitation can be accurately controlled. Subsequent validation on real US-SWEI data is in many cases performed on tissue phantoms such as gelatine. Clearly, validation performance of these procedures is dependent on the accuracy of the simulated tissue phantom and a thorough comparison of simulation and experimental data is needed. In this work, we estimate wave parameters from 400 US-SWEI data sets acquired in various homogeneous gelatine phantoms. We tune a linear material model to these parameters. We report an absolute percentage error for the shear wave velocity between simulation and phantom experiment of <2.5%. We validate our material model on unknown gelatine concentrations and estimate the shear wave velocity with an error <3.4% for in-range concentrations indicating that our material model is in good agreement with US-SWEI measurements. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Current Directions in Biomedical Engineering de Gruyter

Parameter Identification for Ultrasound Shear Wave Elastography Simulation

Loading next page...
 
/lp/de-gruyter/parameter-identification-for-ultrasound-shear-wave-elastography-140DUz1D6K
Publisher
de Gruyter
Copyright
© 2021 by Walter de Gruyter Berlin/Boston
eISSN
2364-5504
DOI
10.1515/cdbme-2021-1008
Publisher site
See Article on Publisher Site

Abstract

AbstractElasticity of soft tissue is a valuable information to physicians in treatment and diagnosis of diseases. The elastic properties of tissue can be estimated with ultrasound (US) shear wave imaging (SWEI). In US-SWEI, a force push is applied inside the tissue and the resulting shear wave is detected by high-frequency imaging. The properties of the wave such as the shear wave velocity can be mapped to tissue elasticity. Commonly, wave features are extracted by tracking the peak of the shear wave, estimating the phase velocity or with machine learning methods. To tune and test these methods, often simulation data is employed since material properties and excitation can be accurately controlled. Subsequent validation on real US-SWEI data is in many cases performed on tissue phantoms such as gelatine. Clearly, validation performance of these procedures is dependent on the accuracy of the simulated tissue phantom and a thorough comparison of simulation and experimental data is needed. In this work, we estimate wave parameters from 400 US-SWEI data sets acquired in various homogeneous gelatine phantoms. We tune a linear material model to these parameters. We report an absolute percentage error for the shear wave velocity between simulation and phantom experiment of <2.5%. We validate our material model on unknown gelatine concentrations and estimate the shear wave velocity with an error <3.4% for in-range concentrations indicating that our material model is in good agreement with US-SWEI measurements.

Journal

Current Directions in Biomedical Engineeringde Gruyter

Published: Aug 1, 2021

Keywords: Ultrasound; Shear Wave Elastography; Shear Wave Simulation; High-Frequency US Imaging; Abaqus

There are no references for this article.