Innovative Ventilation Technology for Operating Rooms

Innovative Ventilation Technology for Operating Rooms AbstractThe purpose of this work was to evaluate the decontamination potential of the Potok system both in an experimental setting in a research Operating Room (OR) with standalone Air Decontamination Units (Potok 150-M-01) and in a clinical setting in a real operating theatre in Moscow. Our experiments showed an impact of the Potok units on the bacterial contamination of the room air according to the Swedish SIS-TS 39:2015 standard. For the initial measurements in our research OR in Weiden this could be shown by a decrease of the bacterial burden at all three different measurement points (OR table, instrumentation tray, periphery). Also the subsequently done measurements in the Moscow hospital verified this decontaminating effectivity of the Potok system. In this case the initial background contamination of the operating theatre was higher than in the research OR in Germany. This bacterial burden could be effectively decreased by the use of the installed Potok based ventilation system. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Current Directions in Biomedical Engineering de Gruyter

Innovative Ventilation Technology for Operating Rooms

Loading next page...
 
/lp/de-gruyter/innovative-ventilation-technology-for-operating-rooms-nOpzmE58j2

References (3)

Publisher
de Gruyter
Copyright
© 2018 the author(s), published by Walter de Gruyter Berlin/Boston
eISSN
2364-5504
DOI
10.1515/cdbme-2018-0044
Publisher site
See Article on Publisher Site

Abstract

AbstractThe purpose of this work was to evaluate the decontamination potential of the Potok system both in an experimental setting in a research Operating Room (OR) with standalone Air Decontamination Units (Potok 150-M-01) and in a clinical setting in a real operating theatre in Moscow. Our experiments showed an impact of the Potok units on the bacterial contamination of the room air according to the Swedish SIS-TS 39:2015 standard. For the initial measurements in our research OR in Weiden this could be shown by a decrease of the bacterial burden at all three different measurement points (OR table, instrumentation tray, periphery). Also the subsequently done measurements in the Moscow hospital verified this decontaminating effectivity of the Potok system. In this case the initial background contamination of the operating theatre was higher than in the research OR in Germany. This bacterial burden could be effectively decreased by the use of the installed Potok based ventilation system.

Journal

Current Directions in Biomedical Engineeringde Gruyter

Published: Sep 1, 2018

Keywords: bacterial burden; decontamination; ventilation technology

There are no references for this article.