Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Electric and magnetic field of different transpositions of overhead power line

Electric and magnetic field of different transpositions of overhead power line AbstractIn Lithuanian and Polish electric power supply systems, the power transmission lines of 400 kV voltage represent one of the most potential sources of electric and magnetic fields generation. The 400 kV double-circuit overhead power transmission line and its surrounding environment were herby described and simulated through Finite Element Method using COMSOL Multiphysic software package. This study includes magnetic and electric field calculations. The study shows that the values of magnetic field strength and electric field strength present in the vicinity of a 400 kV overhead power transmission line tend to exceed limit values established in the Normative. Measurements are suggested to be taken for the purpose of finding maximum values of magnetic and electric field strength. To reduce these values, it is recommended to increase the height of supports, and restrict human personal and economic activities. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Archives of Electrical Engineering de Gruyter

Electric and magnetic field of different transpositions of overhead power line

Loading next page...
 
/lp/de-gruyter/electric-and-magnetic-field-of-different-transpositions-of-overhead-QSMUB1i9jx
Publisher
de Gruyter
Copyright
© 2017 Polish Academy of Sciences
ISSN
2300-2506
eISSN
2300-2506
DOI
10.1515/aee-2017-0045
Publisher site
See Article on Publisher Site

Abstract

AbstractIn Lithuanian and Polish electric power supply systems, the power transmission lines of 400 kV voltage represent one of the most potential sources of electric and magnetic fields generation. The 400 kV double-circuit overhead power transmission line and its surrounding environment were herby described and simulated through Finite Element Method using COMSOL Multiphysic software package. This study includes magnetic and electric field calculations. The study shows that the values of magnetic field strength and electric field strength present in the vicinity of a 400 kV overhead power transmission line tend to exceed limit values established in the Normative. Measurements are suggested to be taken for the purpose of finding maximum values of magnetic and electric field strength. To reduce these values, it is recommended to increase the height of supports, and restrict human personal and economic activities.

Journal

Archives of Electrical Engineeringde Gruyter

Published: Sep 1, 2017

References