Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Comparative Analysis of Methane Concentration Near the Junction of the Longwall and Top Road

Comparative Analysis of Methane Concentration Near the Junction of the Longwall and Top Road AbstractMining of longwalls ventilated by the „U” method is willingly applied in Polish coal-mines due to low costs of workings maintenance, low costs of ventilation and a lower fire threat because of a limited flow of air through goafs. However, such a way of ventilation may pose an increased risk of methane explosion. For this reason, the “U” ventilation has been limited in longwalls with methane risk. The mining regulations in force provide that ventilation methane-bearing capacity, i.e. the intensity of methane flow into the ventilation air cannot exceed 20 m3 CH4/min. The regulations also provide that in the event the absolute methane-bearing capacity, i.e. a sum of methane released to the ventilation air and captured by the methane drainage system is higher than 25 m3 CH4/min and the “U” method of ventilation is applied, the effectiveness of methane drainage should be minimum 50% in relation to the forecast absolute methane-bearing capacity. To streamline the process of ventilation near the junction of the longwall and the gallery carrying off the used air, auxiliary ventilation means are applied, such as a ventilation partition, a ventube – which supplies air without methane or with a low concentration of methane, injectors etc. Application of these means is limited by the cross-section of the heading carrying off the air from the longwall. Deformations of the ventilating roadway, which is usually located in the one-sided vicinity of goafs, may prevent the use of a ventilation partition, which has a negative influence on the conditions of ventilating the junction of the longwall and ventilating roadway. The author of the article also refers to such conditions, presenting average values and maximum concentrations of methane concentrations recorded with four methane concentration sensors, located in the vicinity of the junction of the longwall and ventilating roadway. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Management Systems in Production Engineering de Gruyter

Comparative Analysis of Methane Concentration Near the Junction of the Longwall and Top Road

Loading next page...
 
/lp/de-gruyter/comparative-analysis-of-methane-concentration-near-the-junction-of-the-GqVBgjsiXp
Publisher
de Gruyter
Copyright
© 2019 Marian Zmarzły et al., published by Sciendo
eISSN
2450-5781
DOI
10.1515/mspe-2019-0027
Publisher site
See Article on Publisher Site

Abstract

AbstractMining of longwalls ventilated by the „U” method is willingly applied in Polish coal-mines due to low costs of workings maintenance, low costs of ventilation and a lower fire threat because of a limited flow of air through goafs. However, such a way of ventilation may pose an increased risk of methane explosion. For this reason, the “U” ventilation has been limited in longwalls with methane risk. The mining regulations in force provide that ventilation methane-bearing capacity, i.e. the intensity of methane flow into the ventilation air cannot exceed 20 m3 CH4/min. The regulations also provide that in the event the absolute methane-bearing capacity, i.e. a sum of methane released to the ventilation air and captured by the methane drainage system is higher than 25 m3 CH4/min and the “U” method of ventilation is applied, the effectiveness of methane drainage should be minimum 50% in relation to the forecast absolute methane-bearing capacity. To streamline the process of ventilation near the junction of the longwall and the gallery carrying off the used air, auxiliary ventilation means are applied, such as a ventilation partition, a ventube – which supplies air without methane or with a low concentration of methane, injectors etc. Application of these means is limited by the cross-section of the heading carrying off the air from the longwall. Deformations of the ventilating roadway, which is usually located in the one-sided vicinity of goafs, may prevent the use of a ventilation partition, which has a negative influence on the conditions of ventilating the junction of the longwall and ventilating roadway. The author of the article also refers to such conditions, presenting average values and maximum concentrations of methane concentrations recorded with four methane concentration sensors, located in the vicinity of the junction of the longwall and ventilating roadway.

Journal

Management Systems in Production Engineeringde Gruyter

Published: Sep 1, 2019

There are no references for this article.