Common mode behavior in grid connected DC and AC decoupled PV Inverter topologies

Common mode behavior in grid connected DC and AC decoupled PV Inverter topologies Abstract The transformer-less grid connected inverters are gaining more popularity due to their high efficiency, very low ground leakage current and economic feasibility especially in photovoltaic systems. The major issue which surfaces these systems is that of common mode leakage current which arises due to the absence of an electrical transformer connected between the inverter and the utility grid. Several topologies have evolved to reduce the impact of common mode leakage current and a majority of them have succeeded in eliminating the impacts and have well kept them within the limits of grid standards. This paper compares and analyses the impact of the common mode leakage current for four popular inverter configurations through simulation of the topologies such as H5, H6, HERIC and FBZVR inverters. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Archives of Electrical Engineering de Gruyter

Common mode behavior in grid connected DC and AC decoupled PV Inverter topologies

Loading next page...
 
/lp/de-gruyter/common-mode-behavior-in-grid-connected-dc-and-ac-decoupled-pv-inverter-IPVBDeWEfm

References (22)

Publisher
de Gruyter
Copyright
Copyright © 2016 by the
ISSN
2300-2506
eISSN
2300-2506
DOI
10.1515/aee-2016-0035
Publisher site
See Article on Publisher Site

Abstract

Abstract The transformer-less grid connected inverters are gaining more popularity due to their high efficiency, very low ground leakage current and economic feasibility especially in photovoltaic systems. The major issue which surfaces these systems is that of common mode leakage current which arises due to the absence of an electrical transformer connected between the inverter and the utility grid. Several topologies have evolved to reduce the impact of common mode leakage current and a majority of them have succeeded in eliminating the impacts and have well kept them within the limits of grid standards. This paper compares and analyses the impact of the common mode leakage current for four popular inverter configurations through simulation of the topologies such as H5, H6, HERIC and FBZVR inverters.

Journal

Archives of Electrical Engineeringde Gruyter

Published: Sep 1, 2016

There are no references for this article.