A comparative study of cohesive zone models for predicting delamination fracture behaviors of arterial wall

A comparative study of cohesive zone models for predicting delamination fracture behaviors of... AbstractArterial tissue delamination, manifested as the fracture failure between arterial layers, is an important process of the atherosclerotic plaque rupture, leading to potential life-threatening clinical consequences. Numerous models have been used to characterize the arterial tissue delamination fracture failure. However, only a few have investigated the effect of cohesive zone model (CZM) shapes on predicting the delamination behavior of the arterial wall. In this study, four types of CZMs (triangular, trapezoidal, linear–exponential, and exponential–linear) were investigated to compare their prediction of the arterial wall fracture failure. The Holzapfel–Gasser–Ogden (HGO) model was adopted for modeling the mechanical behavior of the aortic bulk material. The CZMs optimized during the comparison of the aortic media delamination simulations were also used to perform the comparative study of the mouse plaque delamination and human fibrous cap delamination. The results show that: (1) the numerical predicted the relationships of force–displacement in the delamination behaviors based on the triangular, trapezoidal, linear–exponential, and exponential–linear CZMs match well with the experimental measurements. (2) The traction–separation relationship results simulated by the four types of CZMs could react well as the corresponding CZM shapes. (3) The predicted load–load point displacement curves using the triangular and exponential–linear CZMs are in good agreement with the experimental data, relative to the other two shapes of CZMs. All these provide a new method combined with the factor of shape in the cohesive models to simulate the crack propagation behaviors and can capture the arterial tissue failure response well. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Open Physics de Gruyter

A comparative study of cohesive zone models for predicting delamination fracture behaviors of arterial wall

Loading next page...
 
/lp/de-gruyter/a-comparative-study-of-cohesive-zone-models-for-predicting-qS1fTGQggL

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
de Gruyter
Copyright
© 2020 Ting Miao et al., published by De Gruyter
ISSN
2391-5471
eISSN
2391-5471
DOI
10.1515/phys-2020-0134
Publisher site
See Article on Publisher Site

Abstract

AbstractArterial tissue delamination, manifested as the fracture failure between arterial layers, is an important process of the atherosclerotic plaque rupture, leading to potential life-threatening clinical consequences. Numerous models have been used to characterize the arterial tissue delamination fracture failure. However, only a few have investigated the effect of cohesive zone model (CZM) shapes on predicting the delamination behavior of the arterial wall. In this study, four types of CZMs (triangular, trapezoidal, linear–exponential, and exponential–linear) were investigated to compare their prediction of the arterial wall fracture failure. The Holzapfel–Gasser–Ogden (HGO) model was adopted for modeling the mechanical behavior of the aortic bulk material. The CZMs optimized during the comparison of the aortic media delamination simulations were also used to perform the comparative study of the mouse plaque delamination and human fibrous cap delamination. The results show that: (1) the numerical predicted the relationships of force–displacement in the delamination behaviors based on the triangular, trapezoidal, linear–exponential, and exponential–linear CZMs match well with the experimental measurements. (2) The traction–separation relationship results simulated by the four types of CZMs could react well as the corresponding CZM shapes. (3) The predicted load–load point displacement curves using the triangular and exponential–linear CZMs are in good agreement with the experimental data, relative to the other two shapes of CZMs. All these provide a new method combined with the factor of shape in the cohesive models to simulate the crack propagation behaviors and can capture the arterial tissue failure response well.

Journal

Open Physicsde Gruyter

Published: Aug 17, 2020

There are no references for this article.