Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Development of a Fluorescent-Microsphere Immunoassay for Detection of Antibodies Specific to Equine Arteritis Virus and Comparison with the Virus Neutralization Test

Development of a Fluorescent-Microsphere Immunoassay for Detection of Antibodies Specific to... The development and validation of a microsphere immunoassay (MIA) to detect equine antibodies to the major structural proteins of equine arteritis virus (EAV) are described. The assay development process was based on the cloning and expression of genes for full-length individual major structural proteins (GP5 amino acids 1 to 255 GP5 1-255 , M 1-162 , and N 1-110 ), as well as partial sequences of these structural proteins (GP5 1-116 , GP5 75-112 , GP5 55-98 , M 88-162 , and N 1-69 ) that constituted putative antigenic regions. Purified recombinant viral proteins expressed in Escherichia coli were covalently bound to fluorescent polystyrene microspheres and analyzed with the Luminex xMap 100 instrument. Of the eight recombinant proteins, the highest concordance with the virus neutralization test (VNT) results was obtained with the partial GP5 55-98 protein. The MIA was validated by testing a total of 2,500 equine serum samples previously characterized by the VNT. With the use of an optimal median fluorescence intensity cutoff value of 992, the sensitivity and specificity of the assay were 92.6% and 92.9%, respectively. The GP5 55-98 MIA and VNT outcomes correlated significantly ( r = 0.84; P < 0.0001). Although the GP5 55-98 MIA is less sensitive than the standard VNT, it has the potential to provide a rapid, convenient, and more economical test for screening equine sera for the presence of antibodies to EAV, with the VNT then being used as a confirmatory assay. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Clinical and Vaccine Immunology American Society For Microbiology

Development of a Fluorescent-Microsphere Immunoassay for Detection of Antibodies Specific to Equine Arteritis Virus and Comparison with the Virus Neutralization Test

Development of a Fluorescent-Microsphere Immunoassay for Detection of Antibodies Specific to Equine Arteritis Virus and Comparison with the Virus Neutralization Test

Clinical and Vaccine Immunology , Volume 15 (1): 76 – Jan 1, 2008

Abstract

The development and validation of a microsphere immunoassay (MIA) to detect equine antibodies to the major structural proteins of equine arteritis virus (EAV) are described. The assay development process was based on the cloning and expression of genes for full-length individual major structural proteins (GP5 amino acids 1 to 255 GP5 1-255 , M 1-162 , and N 1-110 ), as well as partial sequences of these structural proteins (GP5 1-116 , GP5 75-112 , GP5 55-98 , M 88-162 , and N 1-69 ) that constituted putative antigenic regions. Purified recombinant viral proteins expressed in Escherichia coli were covalently bound to fluorescent polystyrene microspheres and analyzed with the Luminex xMap 100 instrument. Of the eight recombinant proteins, the highest concordance with the virus neutralization test (VNT) results was obtained with the partial GP5 55-98 protein. The MIA was validated by testing a total of 2,500 equine serum samples previously characterized by the VNT. With the use of an optimal median fluorescence intensity cutoff value of 992, the sensitivity and specificity of the assay were 92.6% and 92.9%, respectively. The GP5 55-98 MIA and VNT outcomes correlated significantly ( r = 0.84; P < 0.0001). Although the GP5 55-98 MIA is less sensitive than the standard VNT, it has the potential to provide a rapid, convenient, and more economical test for screening equine sera for the presence of antibodies to EAV, with the VNT then being used as a confirmatory assay.

Loading next page...
 
/lp/american-society-for-microbiology/development-of-a-fluorescent-microsphere-immunoassay-for-detection-of-vZ5vDIdrlI

References (67)

Publisher
American Society For Microbiology
Copyright
Copyright © 2008 by the American Society For Microbiology.
ISSN
1556-6811
eISSN
1556-6811
DOI
10.1128/CVI.00388-07
Publisher site
See Article on Publisher Site

Abstract

The development and validation of a microsphere immunoassay (MIA) to detect equine antibodies to the major structural proteins of equine arteritis virus (EAV) are described. The assay development process was based on the cloning and expression of genes for full-length individual major structural proteins (GP5 amino acids 1 to 255 GP5 1-255 , M 1-162 , and N 1-110 ), as well as partial sequences of these structural proteins (GP5 1-116 , GP5 75-112 , GP5 55-98 , M 88-162 , and N 1-69 ) that constituted putative antigenic regions. Purified recombinant viral proteins expressed in Escherichia coli were covalently bound to fluorescent polystyrene microspheres and analyzed with the Luminex xMap 100 instrument. Of the eight recombinant proteins, the highest concordance with the virus neutralization test (VNT) results was obtained with the partial GP5 55-98 protein. The MIA was validated by testing a total of 2,500 equine serum samples previously characterized by the VNT. With the use of an optimal median fluorescence intensity cutoff value of 992, the sensitivity and specificity of the assay were 92.6% and 92.9%, respectively. The GP5 55-98 MIA and VNT outcomes correlated significantly ( r = 0.84; P < 0.0001). Although the GP5 55-98 MIA is less sensitive than the standard VNT, it has the potential to provide a rapid, convenient, and more economical test for screening equine sera for the presence of antibodies to EAV, with the VNT then being used as a confirmatory assay.

Journal

Clinical and Vaccine ImmunologyAmerican Society For Microbiology

Published: Jan 1, 2008

There are no references for this article.